Single Pressure System Disposable Pressure Transducer Kit for Edwards图1Single Pressure System Disposable Pressure Transducer Kit for Edwards图2Single Pressure System Disposable Pressure Transducer Kit for Edwards图3Single Pressure System Disposable Pressure Transducer Kit for Edwards图4Single Pressure System Disposable Pressure Transducer Kit for Edwards图5Single Pressure System Disposable Pressure Transducer Kit for Edwards图6

Single Pressure System Disposable Pressure Transducer Kit for Edwards

Price $6.00
Min Order 40 Pieces  
Shipping from Guangdong, China
Quantity
-+
Product details
JIBPT-01-EDW
Sterilization
Disposable
Clinical, Hospital
Plastic
CE, ISO13485, TUV Fcs
Without Power
All
Disposable Pressure Transducer
to Measure The Pressure of Blood
Finished Products
Accurate Reading&Error Controlling
Single /Double/Triple Channel Kit
Hemodialysis Catheter
Te,Imported Chip, Brand Chip-Set
Compatiable Adapter
Multi-Connector&Adapter
with Exhaust Valve
Available
Paper-Poly Pouch/Valve Bag/Blister Box /Custom
JCR
Sterile Blister Box
224*113*45mm
Guangdong, China
90181930
Product Description

Disposable IBP Transducer
1.Consistant accurate working during blood pressure monitoring.
2.100000 grade clean workshop and 100% finial test.
3.Sterile and individual pakage.
4 connectors compatible with most monitors.
5.Clear fluid pathway enables priming duringe monitoring.
6.OEM/ODM are available.
7. ISO CE approval


 
Product Description
Properties
Medical Materials & Accessories
Product Name
Abbott disposable IBP transducer
Brand Name
JCR
Model Number
JIBPT-E-01-UT
Detailed Photos
Main technical para
 
meters and working environment requirements:
Disposable Pressure Transducer
Barometric pressure
70~106Kpa
Relative humidity
10~90% (non-condensing)
Operating pressure range
-50 ~ + 300 mmHg
Sensitivity
5.0μV/V/mmHg ±3%
Nonlinearity and hysteresis
full-scale reading±1.5%
Input impedance
1200Ω ~3200Ω
Zero pressure offset
-20mmHg~+20mmHg
Thermal offset shift
≤±0.3mmHg/°C
Offset drift
After warm-up for 20 seconds, drift within 2 mmHg within 8 hours
Thermal span shift
≤±0.1%/°C
Frequency response
Standard pressure set (48 "/ 12") is 40 Hz; Separate sensor > 200 Hz
Defibrillator withstand
Defibrillation depends on the final connection of the equipment.
Leakage current
Leakage current is dependent on the final connection of the equipment
Overpressure load
-400~+4000mmHg
Shock resistance
Withstand falling from one meter for three times
 
Light sensitivity
When exposed to a 3400°K tungsten light, candle light at 3000 feet, it's less than 1 mmHg under rated voltage.
Storage and transport environment requirements
- 20 ° C~ + 60 ° C, < 90%(non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold.
Contact with the human body
≤168h
Intra-system velocity
Flow
2-5mL/h
Intra-system velocity refers to the velocity under 6.00 VDC and 25°C, unless there are additional instructions.
Product shelf-life
3 years
Company Profile

Certifications

Exhibition

Packaging & Shipping

 

                                                                                                                                                                     
Buyer review
Loading review details...
Contact

Shenzhen JCR Medical Technology Limited Company

Audited Supplier4 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

Recommended for you