• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
Medical Supply Disposable IBP Transducers Medical IBP Sensor Compatible Utah图1Medical Supply Disposable IBP Transducers Medical IBP Sensor Compatible Utah图2Medical Supply Disposable IBP Transducers Medical IBP Sensor Compatible Utah图3Medical Supply Disposable IBP Transducers Medical IBP Sensor Compatible Utah图4Medical Supply Disposable IBP Transducers Medical IBP Sensor Compatible Utah图5Medical Supply Disposable IBP Transducers Medical IBP Sensor Compatible Utah图6

Medical Supply Disposable IBP Transducers Medical IBP Sensor Compatible Utah

Price $6.00
Min Order 50 Pieces  
Shipping from Guangdong, China
Quantity
-+
Product details
JIBPT-01-UT
Surgical Supplies Materials
High Polymer Material and Electronic Chips
Ethylene Oxide Sterilization
Three Years
All
With Logo Printing
Medical Materials & Accessories
a Case of 40 Sets/Blister Box /Custom
CE/ISO13485
Disposable Invasive Blood Pressure
JCR
Sterile Blister Box
224*113*45mm
China
90181930
Product Description
 Disposable IBP Transducer

1.Consistant accurate working during blood pressure monitoring.
2.100000 grade clean workshop and 100% finial test.
3..Sterile and individual pakage.
4 connectors compatible with most monitors.
5.Single/double/triple channel are options.

6. OEM/ODM are available.
7.IBP transducer with TE sensor chip
8. ISO CE approval

Product Description

Properties
Medical Materials & Accessories
Product Name
Abbott disposable IBP transducer
Brand Name
JCR
Model Number
JIBPT-01-UT

Detailed Photos

Main technical parameters and working environment requirements:
Disposable Pressure Transducer
Barometric pressure
70~106Kpa
Relative humidity
10~90% (non-condensing)
Operating pressure range
-50 ~ + 300 mmHg
Sensitivity
5.0μV/V/mmHg ±3%
Nonlinearity and hysteresis
full-scale reading±1.5%
Input impedance
1200Ω ~3200Ω
Zero pressure offset
-20mmHg~+20mmHg
Thermal offset shift
≤±0.3mmHg/°C
Offset drift
After warm-up for 20 seconds, drift within 2 mmHg within 8 hours
Thermal span shift
≤±0.1%/°C
Frequency response
Standard pressure set (48 "/ 12") is 40 Hz; Separate sensor > 200 Hz
Defibrillator withstand
Defibrillation depends on the final connection of the equipment.
Leakage current
Leakage current is dependent on the final connection of the equipment
Overpressure load
-400~+4000mmHg
Shock resistance
Withstand falling from one meter for three times
 
Light sensitivity
When exposed to a 3400°K tungsten light, candle light at 3000 feet, it's less than 1 mmHg under rated voltage.
Storage and transport environment requirements
- 20 ° C~ + 60 ° C, < 90%(non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold.
Contact with the human body
≤168h
Intra-system velocity
Flow
2-5mL/h
Intra-system velocity refers to the velocity under 6.00 VDC and 25°C, unless there are additional instructions.
Product shelf-life
3 years



Company Profile

 