• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
IBP Disposable Pressure Transducers Invasive for Utah Type Single-Channel图1IBP Disposable Pressure Transducers Invasive for Utah Type Single-Channel图2IBP Disposable Pressure Transducers Invasive for Utah Type Single-Channel图3IBP Disposable Pressure Transducers Invasive for Utah Type Single-Channel图4IBP Disposable Pressure Transducers Invasive for Utah Type Single-Channel图5IBP Disposable Pressure Transducers Invasive for Utah Type Single-Channel图6

IBP Disposable Pressure Transducers Invasive for Utah Type Single-Channel

Price $6.00
Min Order 40 Pieces  
Shipping from Guangdong, China
Quantity
-+
Product details
JIBPT-01-UT
Surgical Supplies Materials
High Polymer Material and Electronic Chips
Ethylene Oxide Sterilization
Three Years
All
With Logo Printing
CE/ISO13485
Medical Materials & Accessories
JCR
Blister Box
270*175*54mm
China
9018909991
Product Description

Product Description

Properties
Medical Materials & Accessories
Product Name
   IBP Transducers for Utah Type
Brand Name
JCR
Model Number
JIBPT-01-EDW

Detailed Photos

Main technical parameters and working environment requirements:
Disposable Pressure Transducer
Barometric pressure
70~106Kpa
Relative humidity
10~90% (non-condensing)
Operating pressure range
-50 ~ + 300 mmHg
Sensitivity
5.0μV/V/mmHg ±3%
Nonlinearity and hysteresis
full-scale reading±1.5%
Input impedance
1200Ω ~3200Ω
Zero pressure offset
-20mmHg~+20mmHg
Thermal offset shift
≤±0.3mmHg/°C
Offset drift
After warm-up for 20 seconds, drift within 2 mmHg within 8 hours
Thermal span shift
≤±0.1%/°C
Frequency response
Standard pressure set (48 "/ 12") is 40 Hz; Separate sensor > 200 Hz
Defibrillator withstand
Defibrillation depends on the final connection of the equipment.
Leakage current
Leakage current is dependent on the final connection of the equipment
Overpressure load
-400~+4000mmHg
Shock resistance
Withstand falling from one meter for three times
 
Light sensitivity
When exposed to a 3400°K tungsten light, candle light at 3000 feet, it's less than 1 mmHg under rated voltage.
Storage and transport environment requirements
- 20 ° C~ + 60 ° C, < 90%(non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold.
Contact with the human body
≤168h
Intra-system velocity
Flow
2-5mL/h
Intra-system velocity refers to the velocity under 6.00 VDC and 25°C, unless there are additional instructions.
Product shelf-life
3 years


Company Profile

 

Exhibition

 

Certifications

Packaging & Shipping



Buyer review
Loading review details...
Contact

Shenzhen JCR Medical Technology Limited Company

Audited Supplier4 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

You May Like
Home > Products > Health & Medicine > Medical Supply > Disposable Medical Supplies