• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
Electronic Test and Measurement Instrument, Portable Energy Meter Testing Set图1Electronic Test and Measurement Instrument, Portable Energy Meter Testing Set图2Electronic Test and Measurement Instrument, Portable Energy Meter Testing Set图3Electronic Test and Measurement Instrument, Portable Energy Meter Testing Set图4Electronic Test and Measurement Instrument, Portable Energy Meter Testing Set图5Electronic Test and Measurement Instrument, Portable Energy Meter Testing Set图6

Electronic Test and Measurement Instrument, Portable Energy Meter Testing Set

Price $0.00
Min Order 1 Set  
Shipping from Hunan, China
Quantity
-+
Product details
TD4552
Life Time
12 Months Excellent After Service
Electrical Calibration
Electricity
6 V~456 V
2 mA ~ 110 A
With LCD Display
Non-Customized
Class 0.02, 0.05, 0.1
2nd~21st
optional
45Hz~65Hz
0~54kW
TUNKIA
Package for Exporting
China
Product Description
TD4550 Portable Three-Phase Energy Calibrator
Summary

 

TD4550 is an intelligent and highly integrated test system for calibrating three-phase energy meter and other AC electrical apparatus
. It is built-in 3PH standard source. It can complete intrinsic error test, constant test, standard deviation test, starting current test, test of no-load of electric energy meter.
 
Features

 

  1. Accuracy:class 0.02, 0.05, 0.1
  2. 3PH ACV output:6 V~456 V
  3. 3PH ACI output:2 mA ~ 110 A
  4. Multiple output mode, support three-phase or single adjust
  5. U-I phase:0°~360°, accuracy 0.01°
  6. Energy meter test function
  7. LCD touch screen
  8. 2nd~21st harmonic output(option)
  9. Test software(option)
  10.  
Application

 



 
Characteristics

 

 Wide Output
  1. It can meet most single-phase / three-phase meters.
 
 Convenient Operation
  1. Color LCD touch-screen.
  2. Support connect operation keypad with physical keys.


 

 Harmonics Function(Option)
 
 
S/NFunction declaration
 Set amplitude of harmonic.
 Set phase of harmonic(fundamental wave).
 Choose 2nd~21st harmonics channel output.
 Oscilloscope function, user can observe voltage and current waves.
 Display frequency spectrum of harmonic by histogram.(fundament wave is 100%)
 

 Testing Software(Option)
  1. RS232 communication interface,software customizable.
 
Specifications

 

5.1 Three-Phase Voltage / Current Output

Voltage RangeStability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (mA)
Class 0.1Class 0.05Class 0.02Class 0.1Class 0.05Class 0.02
57.7 V0.020.010.005600+400300+200120+80500
100 V0.020.010.005600+400300+200120+80300
220 V0.020.010.005600+400300+200120+80130
380 V0.020.010.005600+400300+200120+8080
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%).
 
Current RangeStability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (V)
Class 0.1Class 0.05Class 0.02Class 0.1Class 0.05Class 0.02
20 mA0.020.010.005600+400300+200120+8024
50 mA0.020.010.005600+400300+200120+8024
100 mA0.020.010.005600+400300+200120+8024
200 mA0.020.010.005600+400300+200120+8024
500 mA0.020.010.005600+400300+200120+8024
1 A0.020.010.005600+400300+200120+8024
2 A0.020.010.005600+400300+200120+806
5 A0.020.010.005600+400300+200120+806
10 A0.020.010.005600+400300+200120+802
20 A0.020.010.005600+400300+200120+802
50 A0.020.010.005600+400300+200120+800.6
100 A0.020.010.005600+400300+200120+800.6
  1. Three-phase voltage output:6 V~456 V, Three-phase current output:2 mA~120 A
  2. Degree of distortion:<0.5%
  3. Degree of symmetry:voltage <0.2%, current <0.5%, phase <0.5°
  4. Voltage short circuit, current open-circuit and overload protection

5.2 Frequency / Phase / Harmonic

Frequency Range:45 Hz~65Hz;
Adjustment fineness:0.001 Hz;
Accuracy:±0.05 Hz (class 0.1), ±0.02 Hz (class 0.05), ±0.01 Hz(class 0.02)
PhaseRange:0.000 0°~359.999 9°;
Adjustment fineness:0.001°;
Accuracy:±0.05° (class 0.1), ±0.02° (class 0.05), ±0.01°(class 0.02)
Harmonic2nd~21st harmonic;
Amplitude 0~25% adjustable;
Phase 0~359.99°adjustable
 

5.3 Power / Energy Output

TypeCurrent rangeClass 0.1Class 0.05Class 0.02
Output power stability
( % / 2min )
50 mA≤I≤120 A0.050.020.01
2 mA≤I< 50 mA0.050.030.02
Active power /energy
|cosΦ| ≥0.5
50 mA≤I≤120 A±0.1%*reading±0.05%*reading±0.02%*reading
2 mA≤I< 50 mA±0.2%*FS±0.1%*FS±0.05%*FS
Reactive power /energy
|sinΦ| ≥0.5
50 mA≤I≤120 A±0.2%*FS±0.1%*FS±0.05%*FS
2 mA≤I< 50 mA±0.5%*FS±0.2%*FS±0.1%*FS
Power factor50 mA≤I≤120 A±0.1%±0.05%±0.02%
2 mA≤I< 50 mA±0.2%±0.1%±0.05%
Note [2] :FS= voltage range ×current range
  1. Power/energy measure range:combination of voltage range and current range
  2. Power factor measure range:-1.000 00…0.000 00…1.000 00
  3. Energy pulse output:High frequency full range is 60 kHz, Low frequency full range is 6 Hz
  4. Energy pulse input:Frequency ≤ 150 kHz, pulse level::0…3.3 V…24 V
  5. Energy error display:auto,resolution as 0.0001%
 
General Specifications

 

Power SupplyAC ( 220 ± 22 ) V,( 50 ± 2 ) Hz
Temperature PerformanceWorking temperature:0°C~45°C;
Storage temperature:-20°C~70°C
Humidity PerformanceWorking humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C
Storage humidity:(20%~80%) R·H,non-condensing
InterfaceRS232
 
Ordering Information

 

Company Profile

Buyer review
Loading review details...
Contact

Tunkia Co., Ltd.

Audited Supplier4 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

Recommended for you