TUNKIA TD1330 Portable Tester for AC EV Charger AC EV Charger tester图1TUNKIA TD1330 Portable Tester for AC EV Charger AC EV Charger tester图2TUNKIA TD1330 Portable Tester for AC EV Charger AC EV Charger tester图3TUNKIA TD1330 Portable Tester for AC EV Charger AC EV Charger tester图4TUNKIA TD1330 Portable Tester for AC EV Charger AC EV Charger tester图5TUNKIA TD1330 Portable Tester for AC EV Charger AC EV Charger tester图6

TUNKIA TD1330 Portable Tester for AC EV Charger AC EV Charger tester

Price $30000.00
Min Order 1 Set  
Shipping from Hunan, China
Quantity
-+
Product details
TD1330
Life Time
12 Months Excellent for Service
Electricity
10mA~78A Measurement
30V Measurement
With LCD Display
Customized
300V
78A
Class 0.05; Class 0.1
TUNKIA
Package for Exporting
China
Product Description
Product Description

 

TD1330 Portable Tester for AC EV charger

1. Summary
The TD1330 is a portable instrument dedicated to on-site inspection of EV AC charging spot, with three-phase AC voltage measurements up to 300 V, three-phase AC current measurements up to 78 A, and AC electrical energy measurement available in class 0.05 / 0.1. The instrument can be combined with TK4720 AC adjustable resistive load to complete the metrology characteristics test and interoperability test of AC charging spot.
 

2. Features

  1. AC harmonic measurement: Harmonics order of 2 to 64 can be detected.
  2. Power waveform display: Real-time charging curve U(t), I(t), P(t), E(t) display and record, etc.
  3. Ambient temperature measurement: Built-in temperature sensor for measuring the ambient temperature of the site to correct the working error.
  4. Clock verification function: Built-in GPS clock module, real-time clock display, and correct the Beijing time of the charging spot.
  5. Integration: Built-in measurement module, charge control guidance circuit, waveform acquisition and other modules, can complete all interoperability test items of AC charging spots.
  6. Built-in vehicle control guidance circuit: AC charging spot interoperability test can be completed, built-in L1, L2, L3, N, PE, CP, CC circuit on-off switch and CP ground short circuit switch, can realize the vehicle AC charging interface circuit fault simulation function. Built-in vehicle-side R2 resistance, R3 resistance simulation equivalent resistance simulation function, R2 resistance has adjustment range of 500 Ω ~ 6800 Ω, with resistance value online continuously adjustable with adjustment fineness of 1 Ω; R3 equivalent resistance has nominal value of 500Ω ~ 13000Ω, with resistance value online continuously adjustable with adjustment fineness of 1 Ω. Each contact point has an on-off switch, which can simulate the on-off state of the contact point.
  7. Waveform acquisition: Built-in 4-channel high-speed waveform acquisition module to ensure long-term operation and zero data loss.
  8. PWM signal measurement: Measure the frequency and duty factor of the PWM signal on the CP line in the control guidance circuit and display it in real time.
  9. High reliability: No switches, relays and other mechanical contacts in the current loop, can be overloaded at 2 times the rated current for 5 s.
  10. Calibration and verification: With dedicated calibration terminals, the device can be calibrated or verified by two methods, and the TK4965 AC charging electrical energy calibration adapter is optional.
  11. High-definition LCD touch color screen.
  12. Ethernet, WIFI, USB, CAN-BUS interface and host computer software.
  13. Support input of commercial power, built-in lithium battery and EV charger power supply.
  14. Equipped with portable instrument box, high seismic and electrical protection level.

3. Application

Appearance

 


 Instrument Front Panel
S/NFunction description
 AC charging socket, using a dedicated charging connector to connect the inspected AC charging spot.
 A dedicated interface for voltage calibration.
 Auxiliary test point to transfer the AC charging socket to a conventional instrument terminal.
 AC charging socket, use a dedicated charging connector to connect the load or electric car.
 Multi-function interface: support photoelectric head, pulse input, pulse output, temperature sensor and other functions.
 Communication interface: including USB and LAN ports
 A GPS antenna that receives a standard clock signal to correct the time of the AC charging spot under test.
 Built-in large-capacity lithium battery.
 AC 220V power interface to power the instrument via commercial power
 LCD touch color screen, multi-power intuitive display, full touch operation.
 Instrument box lever, easy for user to carry the mobile tester.
 
Specifications

 

5.1 Three-phase ACV measurement
RangeResolutionAccuracy
( ± ppm of reading + ppm of range) [1]
Temp. Coefficient, ±ppm*RD /°C
@-25ºC~55ºC
Class 0.1Class 0.05Class 0.1Class 0.05
240 V0.1 mV400 + 100200 + 503020
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).
  1. Range: Manual/auto shift
  2. Measurement range: 30 V ~ 300 V
  3. Harmonic measurement uncertainty (k = 2): 0.05% * RG, RMS

5.2 Three-phase ACI measurement
RangeResolutionAccuracy
( ± ppm of reading + ppm of range)
Temp. Coefficient, ±ppm*RD /°C
@-25ºC~55ºC
Class 0.1Class 0.05Class 0.1Class 0.05
100 mA0.1 μA400 + 100200 + 505020
200 mA0.1 μA400 + 100200 + 505020
500 mA0.1 μA400 + 100200 + 505020
1 A1 μA400 + 100200 + 505020
2 A1 μA400 + 100200 + 505020
5 A1 μA400 + 100200 + 503020
10 A10 μA400 + 100200 + 503020
30 A10 μA400 + 100200 + 503020
60 A10 μA400 + 100200 + 503020
  1. Range: Manual/auto shift
  2. Measurement range: 10 mA ~ 78 A
  3. Harmonic measurement uncertainty (k = 2): 0.05% * RG, RMS

5.3 Frequency and phase
  1. Frequency range: 45.000 Hz to 65.000 Hz.
Resolution: 0.001 Hz, uncertainty (k=2): 0.01 Hz.
  1. Phase range: 0.000°~359.999°
Resolution: 0.001°, uncertainty (k=2): 0.025°.
 

5.4 P/E Energy Measurement

Electrical energy under testAccuracy
Class 0.1Class 0.05
Active power/electrical energy
|cosΦ| ≥0.5;
0.1%*RD0.05%*RD
  1. Measuring range of power/energy: Combination of AC voltage and AC current range;
  2. Power factor measurement range: -1.000000…0.000000…1.000000
  3. Standard electrical energy pulse output: maximum frequency is 60 kHz
Supports active and passive pulses, load capacity: greater than 20 mA
  1. Standard electrical energy pulse input: maximum frequency is 100 kHz, level: 0 ~ 5V

5.5 Temperature Clock
 
DC power / electrical energyRange-30ºC~60ºC
Accuracy0.3ºC
Clock functionTiming modeGPS clock timing
Accuracy1s/d



6. General Specifications
 
Power supply modeEV charger, built-in lithium battery, 220V commercial power
Power supplyAC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz
Max. Power80 VA
Communication interfaceUSB, LAN, WIFI
Temperature performanceOperating temperature: -25°C~55°C;
Storage temperature: -30°C~70°C
Humidity PerformanceOperating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C
Storage humidity: <80% R·H, non-condensing.
Altitude< 3000 m
WeightAbout 13 kg