NB380-100KSZ
Yes
2 Years
Passive inverter
Three
>1000W
CE, ISO9001
DC/AC Inverters
Solar Power, Wind Power
Full-Bridge Type
Sine Wave Inverter
100kw off Grid Sine Wave Three Phase Inverter
Solar Power System Home
Pure Sine Wave Output
Display
278A / 152A / 145A
220 VAC / 380 VAC / 400 VAC ± 1%
50Hz / 60Hz ±0.05%
94%
Deming
Wooden Case
750*1500*1700mm 730kg
China Jinan
8504403090
Product Description








50KW off grid three phase inverter technical parameter
| Type | NB480-50KSZ | NB380-50KSZ | |
| DC input | Input rated voltage | 480 VDC | 380 VDC |
| Input rated current | 115 A | 146 A | |
| Input DC voltage range | 400-620 VDC | 320-496VDC | |
| AC input (AC Bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
| Input rated current | 139A / 76A / 72.5A | ||
| Bypass transfer time | ≤100ms (Can be customized ≤4ms version) | ||
| AC output | Output rated power | 50KW | |
| Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
| Output rated current | 139A / 76A / 72.5A | ||
| Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
| Output frequency accuracy | 50Hz / 60Hz ±0.05% | ||
| Waveform distortion (THD). | ≤3% (Linear load) | ||
| Dynamic response time (Load 0←→100%) | 2ms | ||
| Power factor (PF) | 1 | ||
| Overload capacity | 120%,5 minutes;200%,3 seconds | ||
| Crest factor (CF) | 3:1 | ||
| Inverter efficiency | 94% | ||
| Working Environment | Dielectric strength | 1500VAC,1minute | |
| Noise (1m) | ≤50dB | ||
| Ambient temperature | -20ºC~+60ºC | ||
| Humidity | 0~90%, No condensation | ||
| Altitude | <6000m Higher than 2000m rated power should be reduced | ||
| Pure Sine Wave | Yes | ||
| Equipped with copper transformer | Yes | ||
| Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
| AC Charger | Optional | ||
| Solar Charger | Optional | ||
| Generator port | Optional | ||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
| Size(mm) | 660*1300*1600mm | ||
| Weight(kg) | 450kg | ||
60KW off grid three phase inverter technical parameter
| Type | NB380-60KSZ | NB480-60KSZ | |
| DC input | 220 VDC | 380 VDC | 480 VDC |
| 68 A | 175 A | 139 A | |
| 180-300 VDC | 320-496VDC | 400-620 VDC | |
| AC input (AC Bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
| Input rated current | 153.6A / 91A / 86A | ||
| Bypass transfer time | ≤100ms (Can be customized ≤4ms version) | ||
| AC output | Output rated power | 60KW | |
| Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
| Output rated current | 153.6A / 91A / 86A | ||
| Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
| Waveform distortion (THD). | ≤3% (Linear load) | ||
| Dynamic response time (Load 0←→100%) | 2ms | ||
| Power factor (PF) | 1 | ||
| Overload capacity | 120%,5 minutes;200%,3 seconds | ||
| Crest factor (CF) | 3:1 | ||
| Inverter efficiency | 94% | ||
| Working Environment | Dielectric strength | 1500VAC,1minute | |
| Noise (1m) | ≤50dB | ||
| Ambient temperature | -20ºC~+60ºC | ||
| Humidity | 0~90%, No condensation | ||
| Altitude | <6000m Higher than 2000m rated power should be reduced | ||
| Pure Sine Wave | Yes | ||
| Equipped with copper transformer | Yes | ||
| Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
| AC Charger | Optional | ||
| Solar Charger | Optional | ||
| Generator port | Optional | ||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
| Size(mm) | 750*1500*1700mm | ||
| Weight(kg) | 680kg | ||
75KW off grid three phase inverter technical parameters
| Type | NB380-75KSZ | NB240-75KSZ | |
| DC input | Input rated voltage | 380 VDC | 240 VDC |
| Input rated current | 219 A | 347 A | |
| Input DC voltage allowing range | 320-496 VDC | 200-310 VDC | |
| AC input (AC Bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
| Input rated current | 192A /114A / 108A | ||
| Bypass transfer time | ≤100ms (Can be customized ≤4ms version) | ||
| AC output | Output rated power | 75KW | |
| Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
| Output rated current | 192A /114A / 108A | ||
| Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
| Waveform distortion (THD). | ≤3% (Linear load) | ||
| Dynamic response time (Load 0←→100%) | 2ms | ||
| Power factor (PF) | 1 | ||
| Overload capacity | 120%,5 minutes;200%,3 seconds | ||
| Crest factor (CF) | 3:1 | ||
| Inverter efficiency | 94% | ||
| Working Environment | Dielectric strength | 1500VAC,1minute | |
| Noise (1m) | ≤50dB | ||
| Ambient temperature | -20ºC~+60ºC | ||
| Humidity | 0~90%, No condensation | ||
| Altitude | <6000m Higher than 2000m rated power should be reduced | ||
| Pure Sine Wave | Yes | ||
| Equipped with copper transformer | Yes | ||
| Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
| AC Charger | Optional | ||
| Solar Charger | Optional | ||
| Generator port | Optional | ||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
| Size(mm) | 750*1500*1700mm | ||
| Weight(kg) | 680kg | ||
100KW off grid three phase inverter technical parameters
| Type | NB360-100KSZ | NB380-100KSZ | |
| DC input | Input rated voltage | 360 VDC | 380 VDC |
| Input rated current | 309 A | 292 A | |
| Input DC voltage range | 300-465 VDC | 320-496VDC | |
| AC input (AC Bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
| Input rated current | 278A / 152A / 145A | ||
| Bypass transfer time | ≤100 ms (Can be customized ≤ 4ms version) | ||
| AC output | Output rated power | 100KW | |
| Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | ||
| Output rated current | 278A / 152A / 145A | ||
| Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
| Output frequency accuracy | 50Hz / 60Hz ±0.05% | ||
| Waveform distortion (THD). | ≤3% (Linear load) | ||
| Dynamic response time (Load 0←→100%) | 2ms | ||
| Power factor (PF) | 1 | ||
| Overload capacity | 120%,5 minutes;200%,3 seconds | ||
| Crest factor (CF) | 3:1 | ||
| Inverter efficiency | 94% | ||
| Working Environment | Dielectric strength | 1500VAC,1minute | |
| Noise (1m) | ≤50dB | ||
| Ambient temperature | -20ºC~+60ºC | ||
| Humidity | 0~90%,No condensation | ||
| Altitude | <6000m Higher than 2000m rated power should be reduced | ||
| Pure Sine Wave | Yes | ||
| Equipped with copper transformer | Yes | ||
| Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
| AC Charger | Optional | ||
| Solar Charger | Optional | ||
| Generator port | Optional | ||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
| Size(mm) | Product Size: 650*1400*1500 | Package Size: 750*1500*1700 | |
| Weight(kg) | 730kg | ||