• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
ZW32-12 Type Outdoor HV Vacuum Circuit Breaker图1ZW32-12 Type Outdoor HV Vacuum Circuit Breaker图2ZW32-12 Type Outdoor HV Vacuum Circuit Breaker图3ZW32-12 Type Outdoor HV Vacuum Circuit Breaker图4ZW32-12 Type Outdoor HV Vacuum Circuit Breaker图5ZW32-12 Type Outdoor HV Vacuum Circuit Breaker图6

ZW32-12 Type Outdoor HV Vacuum Circuit Breaker

Price $1750.00
Min Order 1 Set  
Shipping from Shaanxi, China
Quantity
-+
Product details
ZW32-12
High Voltage Circuit Breakers
Electric Type
Normal Type Circuit Breaker
Vacuum
Fixed
ACB
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
VDE, ISO9001-2000, CE
12kv
630A
50/60Hz
Longxiang Electric
Non-Solid Wooden Case for Export Shipment
IEC: M2-E2-C2
Baoji, Shaanxi China
85389000
Product Description
ZW32-12 Type Outdoor HV Vacuum Circuit Breaker

General Description
ZW32-12 type outdoor high voltage vacuum circuit breaker is three-phase AC, 50(60) Hz outdoor power 
distribution equipment with the rated voltage of 12kV. It is mainly used to break and close the load current,
and short circuit current in the electric power system. It fits to be used to protect and control the circuit in 
substation, mining and industrial enterprises.It also can be used in the frequently operation places such as 
the rural power network. 

The product is accordance with GB1984-2003 standard.

The ZW32-12G VCB -Isolating switch combination consists of Vacuum circuit breaker body and isolating switch. 
 
Applying ambient conditions
1.Ambient temperature:-30ºC~+40ºC.
2.The height above sea level:≤1000m(besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.
4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa:the  average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8 degrees.
6.Wind pressure should be no more than 700pa(it is equivalent to wind speed of 34m/s).
7.The air filthy should be within III degree.
8.It should be installed in the places without fire,explosion,serious filth, chemical erosion and violent vibration.
 


 


Our Factory 









Packing & Delivery





Welcome for inquiry and factory visit!