YCB9ZF-100AP 4G
Low Voltage Circuit Breakers
Manual Type
Normal Type Circuit Breaker
Air
Insert
MCB
1p+N, 3p+N
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
CE
1p+N, 3p+N
32A, 63A, 100A
30-500mA
Icn=Lcs=6ka
More Than 20000 Times
More Than 6000 Times
IP20
40c~70c
Single Phase AC230V, Three Phase AC440V
RS485 Standard; 4G, WiFi, Nb, RJ45 Optional
CNC
OEM/CNC
YCB9ZF-100AP WIFI
Zhejiang, China
8536200000
Product Description
CNC YCB9ZF IP20 6KA 32A 63A 100A Breaking Capacity Smart MCB WiFi Miniature Circuit Breaker


Poles | 1P+N,3P+N | 1P,2P3P,4P |
Rated voltage | Single-phase AC230V,50/60Hz; Three-phase AC440V, 50/60Hz | |
Rated current | 32A,63A,100A | |
Residual operating current | 30-500mA | |
Short circuit breaking capacity | Icn=Ics=6kA | |
Mechanical life | More than 20000 times | |
Electrical life | More than 6000 times | |
Action time | Leakage action less than 100ms; Closing time is less than 1.5s and opening time is less than 1S | |
Protection grade | IP20 | |
Operating environment temperature 40 ºC~70ºC |
Maintenance safety lock: greatly ensure the personal safety of maintenance personnel;
Protection against electric theft cover plate: it can effectively prevent electric theft, private cable, etc.
Independent power supply design: it can effectively prevent the whole system from being paralyzed and unable to work;
1.3 inch OLED display design: Provide more intuitive man-machine operation interface for maintenance personnel;
modular design: optional collocation, more flexible use;;
High accuracy: voltage and current detection accuracy level 0.5, power accuracy level 1.0;
The overall function of the circuit breaker saves the characteristics of the miniature circuit breaker;
Flexible choice of communication mode, can also do gateway use;
Flexible choice of function shutdown, alarm and tripping protection mode;
A variety of remote upgrade mode, so that users upgrade maintenance no longer trouble;
Power off protection design: After the power off of the main circuit, the data can be saved and uploaded without loss;
Automatic judgment and analysis of fault causes and operation events, display log, convenient for maintenance and troubleshooting;
The functions of load imbalance, missing phase, wrong phase and over temperature protection greatly ensure the aging of equipment and lines, and ensure the safety of electricity use;
Timing switch function: guarantee the timing switch of equipment, guarantee energy consumption and save electricity;
The leakage action protection is sensitive. Different leakage protection values canbe set according to the use environment.