• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
Vlf High Voltage Test Set Integrated Tan Delta Diagnostic图1Vlf High Voltage Test Set Integrated Tan Delta Diagnostic图2Vlf High Voltage Test Set Integrated Tan Delta Diagnostic图3Vlf High Voltage Test Set Integrated Tan Delta Diagnostic图4Vlf High Voltage Test Set Integrated Tan Delta Diagnostic图5Vlf High Voltage Test Set Integrated Tan Delta Diagnostic图6

Vlf High Voltage Test Set Integrated Tan Delta Diagnostic

Price $25000.00
Min Order 1 Piece  
Shipping from Hubei, China
Quantity
-+
Product details
VLF-40TD
ISO9001
Shock Resistance
Power Test Equipment
IP67
0.1Hz-0.01Hz
GOLDSOL
Plywood Case
CE
China
903033900
Product Description

VLF Advantage

1.AC Withstand voltage testing, Voltage & current curve display.
2.Tan delta (tgδ test), capacitance (μF) and IR (Ω) Test without external device.
3.Partial discharge testing without external device (for buyer's option).
4.DC withstandi voltage test,DC leakage current measurement (for buyer's option).
5."IEE 400.2" Analysis of Tan delta test result for option
6.Safe Optical isolation technology.
7. Easiest to use Fully automatic microcontroller.
8. H/L voltage closed loop negative feedback control circuit, output no capacity rise effect.
9. Built-in printer.
10. Built-in protective resistors.                              
11. Colour Touch LCD (154*86mm)operation, True sine wave output.
12. Real-time display of actual output waveform.       
13. Ergonomic, menu guided, large colour touch screen
14. Storage of test results for later retrieval and print.                       
15. Over voltage and current protected.
16.Auto variable frequency 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz.
17. 60 mins continuous working;
18. Data of current, voltage and waveform directly sampled at HV side.
19. Rugged and reliable design less prone to failure from transients.
20. Invatation Patent                                                   
21. Portable: Control unit + Booster (Tank)
22. CE mark.
23. RS232 for option.
24. Remote control system for option



Specification
1.Power: 220V ± 10% AC (110V can be customized), 50/60Hz, single phase;
2.Output-Voltage (Peak): 1 to rated value (KV), details see the below table;
3.Output frequency: 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz (auto variable frequency);
4.Load: 0.5μF (approx 6,000 ft of cable)  @ 0.1 Hz 
       1.0μF (approx 12,000 ft of cable) @ 0.05 Hz 
       2.5μF (approx 30,000 ft of cable) @ 0.02 Hz 
       5.0μF (approx 60,000 ft of cable) @ 0.01 Hz 
5. Stability of frequency: Fluctuation < 0.5%;
6. Measurement accuracy: ±3%;
7. Positive and negative voltage peak error: ≤3%;                             
8. Voltage waveform distortion: ≤5%;                                 
9. Construction: 1 Control unit + 1 Booster (60KV set);  1 Control unit + 2 Boosters(60KV set).
10. Ambient conditions of use: temperature Indoor and outdoor : -10ºC ~ + 50ºC.         
11. Humidity:≤85% 
12. Technical indexes of VLF tgδ test:
  1) tgδ test voltage range: 1 to 40KV (Only one booster can be used for tan delta test if 2 boosters set)
  2) Measurement voltage accuracy: 3%
  3) Dielectric loss test frequency: 0.1Hz
  4) Measurement range: 0.01×10-3- 655.35×10-3
  5) Dielectric loss accuracy: 1x10-4
  6) Dielectric loss resolution: 1x10-5
  7) Capacitance measurement range: 0.001μF-10μF
  8) Celectric capacity resolution: 0.001μF                    
  9) Current measurement range: 0-59mA                         
  10) Current resolution: 0.1mA
  11) Insulation resistance: 0.01GΩ-65.53GΩ
  12) Insulation resistance resolution: 10

13.Main technical indexes of VLF PD test (for option):
  1) Partial discharge measurement range: 0.1pc-5000pc
  2) Partial discharge detection sensitivity: 0.1pc
  3) Capacitance range: 0.001μF-10μF
  4) Sampling bits: 12 bits
  5) Sampling speed: 200M/S                                           
  6) Test voltage:  0 to rated value (KV)

14.DC leakage current measurement (for option):
  1) Output rated voltage: same as rated AC voltage output
  2) Voltage accuracy: 3%
  3) Leakage current range: 0-2000μA or 0-20mA
  4) DC Current resolution: 1μA
  5) DC current accuracy: 3%
  6) It is necessary to parallel the capacitor we supplied if testing DC leakage current.
 

Model no
Output
Voltage/
Current
(Peak)
Load CapacityControl UnitBooster(Tank)Power 
Capacitance/
Freuency
Net Dim.
(cm)
Net Wt
 (kg)
Net Dim.
(cm)
Net Wt
(kg)
VLF-40TD 40KV/30mA0.1Hz-0.01Hz
Auto Variable
Capacity:≤10µF
46×31×50  35  --  --1000W
VLF-80TD 80KV/59mA0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 80KV
46×31×50  3536x19×45    453000W
      







Analysis of Tan delta test results (IEE400.2)



Field connection diagram
          It gives 80KV output when external connecting 40KV tank.
            
Package for transport

1) 40KV test set:
Sr no Name of Commodity  Qty N.W G.WTransport size
(LxWxH)
140KV test set
Including 1 capacitor
1 unit35 kg50 kg580x400x500mm
                    Total:1 set35 kg50 kg0.12 m3
                                                       Packed in 1 wooden case.
 
 2) 80KV test set:
Sr no Name of Commodity  Qty N.W G.WTransport size
(LxWxH)
1Controll part1 unit35 kg50 kg550x400x500mm
2Tank1 unit45 kg69 kg470x430x720mm
Capacitor1 unit4 kg
Aluminum alloy box  1 unit6 kg
 
                    Total:1 set90 kg119 kg0.26 m3
                                                      Packed in 2 wooden cases.


Accessories
Sr no.     DescriptionQuantityRemarks
  1Control part1unit 
  2Booster  (Tank)1unitNo tank for 40KV
  3Capacitor (0.04µF)1unitUsed as Capacity supplement, or test object for demo
  4Discharge rod1unit 
  5HV Test/Connection cables1set 
  6Earth cable1unit 
  7Power supply cable1unit 
  8Fuse2units 
  9Printer paper1unit 
 10Operating manual 1unit 
 11Aluminium alloy box1unitNo this item for 40KV
 12Calibration report1unit 


Buyer review
Loading review details...
Contact

GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY

Audited Supplier14 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

Recommended for you