8S
Veterinary Radiography System
Flat Panel Deetector
Energy Storage High Voltage Generator
Cannon High Quality X-ray Tube
Visualized with Dynamic Monitoring
with Pedal Exposure Break
Dongjiang, CMICS
Huizhou, China
9018199000
Product Description
Veterinary Radiography System X-ray Machine with 7 inch LCD
Model: 8SFeatures |
| Novel appearance, excellent image chain configuration and intelligent operation experience |
| 7 inch LCD touch screen with friendly interface & clear display |
| Large size flat panel detector of 17 x 17 inch covering wide shooting range for superior imaging |
| Standard integrated console with easy use to realize startup, shutdown manual exposure |
| Pedal contolled exposure (Optional) |
| Split design of rack and table for minimum sapce, east movement and convenient installation |
| Portable high voltage generator with single phase, integrated x-ray tube and collimator, for easy installation & disassembly |
| Flat panel detector with high spatial resolution, excellent image, lower dosage, IP54 protection against dust & water sprays |
| Universal wheels at the bottom of the table for easy movment |
| Available with emergency quick exposure at the lowest exposure dose, DICOM image export and data trieval |
| Panoramic stiching of multiple images |
| VHS (Vertebral Heart Size) measurement to help diagnose dialted heart disease, mitral valve endocarditis and heart failure |
| TTA (Tibial Trochanteric Advancement) measurement to help treat anterior curciate ligament (ACL) rupture in the knee joint |
| TPLO (Tibial Plateau Levelling Osteotomy) measurement to help treatment of knee related condictions due to CL rupture |
| HD (Hip Dysplasia) measurement for assessing severity of inflammationand jpint laxity |
| Particularly designed with preset shooting parameters for common animals and various exotic pets and exposure dosage |













Generator |
| Power Source Condition | Single phase, 220V/110V, AC |
| Output Power | 8 kW |
| Tube Voltage | 40 ~ 125 kV |
| Tube Current | 3.2 ~160 mA |
| Loading Time | 1 ~ 10000 mS |
| Current Time Proudct | 0.1 ~ 250 mAs |
| Nominal Output Power | 8 kW (100 kV, 80 mA, 0.1 s) |
| Instantaneous Power | 3 KVA |
| Inverter Frequency | 100kHz |


Tube |
| Maximum X-ray Tube Voltage | 125KV |
| Focal Spot | 2.0mm |
| Rotation Speed | 2700rpm@50Hz 3200rpm@60Hz |
| Target Anode Angle | 15° |
| Permanent Filtration | 0.65 mm Al@75kV |
| Anode Heat Content | 30 kJ |
| Weight | 0.3 kg |
DROC Software & Workstation Computer |
| Imaging Processing | Exposure dose display&adjustment |
| Zoom in/out, Rotation and Mirror | |
| Image Stitching | |
| Support VHS, TTA, TPLO and HD function | |
| Data Interface and Transmit | DICOM 3.0 standard |
| Support export PNG format Image | |
| CPU | I3 |
| RAM | 4G |
| Hardware Drive | 1 TB |
| OS | Windows 10 professional edition |
| Screen Size | 23 inches |
| Resolution | 1920×1080 |


Detector |
| Scintillator | Csi |
| Image Sensor | a-Si(Amorphous Silicon) TFT |
| Active Area Size | 428×428mm (17"×17") |
| Active Area Pixel | 3072×3072 Pixels |
| Pixel Pitch | 140 μm |
| Spatial Resolution | 3.4 Lp/mm |
| A/D Conversion | 16bits |
| DQE | ≥62% |
| Imaging Time | 5 s |
| Preview Time | 3 s |
| Ingress Protection | IPX4 |
Table |
| Column Height | 1920mm ± 5% |
| SID | 1050mm ± 5% |
| Table Size (length * width) | 1200*650mm |
| Height of Table to the Ground | 730mm |
| Table Movement | Separable movement of the table. Four casters have their own pedal brake. |
| Weight Capacity | 60kg |