• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator图1Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator图2Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator图3Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator图4Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator图5Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator图6

Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator

Price $20000.00
Min Order 1 SET  
Shipping from Fujian, China
Quantity
-+
Product details
MC
Responsible
12 Months or 1000 Operation Hours
Self-Starting Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Low Speed
Land Use
Common Units, Standby Unit, Emergency Crew
Automation Type
Static Exciter
Water/Air Cooled Deutz or Beinei
Mecca Power, Leroy Somer, Optional
Deepsea/Comap/Deif/Smartgen and Others
Silent Soundproof/Weather Proof/Anti-Rusted Proof
50Hz/60Hz
220-440V; 110-480V
Telecom Communication Base
Remote Control Generator
Mech/Elec/ECU/Ecm/Adec/Hpcr
Diesel Generator Continuous Running 24/7
as Application Requested
CE, ISO, OEM Authorization etc.
China Brand Generator
Emergency Diesel Generator
Big Fuel Tank Generator
Mecca
Both Standard Marine Packing or Compact Packing.
As below Spec. with details
China
850211
Product Description
Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.

Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.


Product Description

In the dynamic realm of telecommunications, every connection matters. MECCA Diesel Generators provide a seamless power supply, ensuring your telecom operations run smoothly 24/7.

(1)1000pcs 20-75kVA/Year
(2)Water/Air Cooled Engine
(3)Remote Control
(4)Continuous Running
(5)Double Stacking
(6)With Big Fuel Tank(1000L,1500L,2000L,3000L etc.)
(7)Automatic Fuel Feeding
Specification
Powered by BEINEI                                                                                          50HZ  220-440V 17-124KVA 
ModelLTPPRPEngineFuel Cons.CylinderDisplacementGov.DimentionWeight
KVA / KW KVA/KW ModelOriginL/H(100%)LL*W*H (MM)KGS
MC17AD17 13 15 12F2L912CN3.96 2L/NA1.880 M1460*900*1170588 
MC28AD28 22 25 20F3L912 CN6.62 3L/NA2.828  M 1460*900*1170680 
MC33AD33 26 30 24F4L912 CN8.68 4L/NA3.770 M1650*900*1170764 
MC39AD39 31 35 28F4L913 CN9.22 4L/NA4.086  M 1850*820*1200890 
MC44AD44 35 40 32F4L912T CN11.13 4L/TC3.770 M1850*820*1200970 
MC55AD55 44 50 40F6L912 CN13.02 4L/NA5.655  M 2250*820*12401080 
MC61AD61 48 55 44F6L913 CN13.84 4L/NA6.128 M2250*820*12401120 
MC69AD69 55 63 50F6L912T CN16.55 4L/TC 5.655  M 2250*820*12401200 
MC83AD83 66 75 60BF4L913CN15.70 4L/TC 4.086 E2250*820*12401320 
MC99AD99 79 90 72BF6L913 CN23.88 4L/TCA6.128 E2250*820*12401320 
MC124AD124 99 113 90BF6L913CCN29.85 4L/TCA6.128 E2250*820*12401480 
Powered by  DEUTZ                                                                              50HZ  220-440 V   22-825KVA                                                         
ModelLTPPRPEngineFuel Cons.CylinderDisplacementGov.Dimention  Weight
KVA / KW KVA/KW ModelOriginL/H(100%)LL*W*H (MM)(KGS)
MC22D22 18 20 16BFM3 G1CN5.40 4L/NA3.168 E1600*880*1250560 
MC33D33 26 30 24BFM3 G2CN7.70 4L/NA3.168 E1600*880*1250582 
MC44D44 35 40 32BFM3TCN10.30 4L/TC3.168 E1600*880*1250640 
MC55D55 44 50 40BFM3CCN11.20 4L/TCA3.168 E1600*880*1250680 
MC66D66 53 60 48BF4M2012CN13.70 4L/TC4.040  M 1870*980*1500970 
MC83D83 66 75 60BF4M2012C G1CN18.10 4L/TCA4.040  M 1960*980*15001010 
MC99D99 79 90 72BF4M2012C G2CN21.30 4L/TCA4.040 E1960*980*15001040 
MC110D110 88 100 80BF4M1013EC G1CN20.90 4L/TCA4.764  M 2140*980*17001180 
MC124D124 99 113 90BF4M1013EC G2CN24.20 4L/TCA4.764 E2140*980*17001220 
MC138D138 110 125 100BF4M1013FCCN28.90 4L/TCA4.764 E2140*980*17001310 
MC176D176 141 160 128BF6M1013EC G1CN35.90 6L/TCA7.146 M2280*980*17001480 
MC198D198 158 180 144BF6M1013EC G2CN39.20 6L/TCA7.146 E2280*980*17001590 
MC206D206 165 188 150BF6M1013FC G2CN40.60 6L/TCA7.146 E2640*1150*17901710 
MC220D220 176 200 160BF6M1013FC G3CN45.60 6L/TCA7.146 E2640*1150*17901760 
MC275D275 220 250 200TCD 8.0CN51.60 6L/TCA7.800 ECU2710*1150*17902640 
MC330D330 264 300 240TCD 8.7CN51.57 6L/TCA8.700 ECU3050*1150*17602820 
MC1000D1000 800 325 260TCD12.1 G1CN64.646L/TCA12.100 ECU3050*1150*17602820 
MC413D413 330 375 300TCD12.1 G2CN76.796L/TCA12.100 ECU3050*1150*17602990 
MC495D495 396 450 360TCD13.0 G1CN88.77 6L/TCA12.940 ECU3600*1400*21003170 
MC550D550 440 500 400TCD13.0 G2CN100.06 6L/TCA12.940 ECU3600*1400*21003270 
MC248D248 198 225 180BF6M1015-LA GACN49.60 6V/TC11.906 E2650*1520*21002320 
MC275D275 220 250 200BF6M1015C-LA G1ACN53.80 6V/TCA11.906 E2650*1520*21002320 
MC303D303 242 275 220BF6M1015C-LA G2ACN60.40 6V/TCA11.906 E2750*1520*21002510 
MC344D344 275 313 250BF6M1015C-LA G3ACN67.20 6V/TCA11.906 E2850*1520*21002520 
MC385D385 308 350 280BF6M1015C-LA G4CN74.00 6V/TCA11.906 E2850*1520*21002610 
MC413D413 330 375 300BF6M1015CP-LA GCN79.30 6V/TCA11.906 E2950*1520*21002695 
MC481D481 385 438 350BF8M1015C-LA G1ACN92.50 8V/TCA15.875 E3100*1850*22403120 
MC495D495 396 450 360BF8M1015C-LA G2CN97.50 8V/TCA15.875 E3100*1850*22403240 
MC523D523 418 475 380BF8M1015CP-LA G1ACN100.00 8V/TCA15.875 E3100*1850*22403300 
MC550D550 440 500 400BF8M1015CP-LA G2CN108.40 8V/TCA15.875 E3100*1850*22403380 
MC605D605 484 550 440BF8M1015CP-LA G4CN116.10 8V/TCA15.875 E3100*1850*22403450 
MC619D619 495 563 450BF8M1015CP-LA G5CN123.10 8V/TCA15.875 E3100*1850*22404200 
MC756D756 605 688 550HC12V132ZL-LAG1ACN137.40 12V/TCA23.812 E3700*1600*22004200 
MC825D825 660 750 600HC12V132ZL-LAG2ACN152.60 12V/TCA23.812 E3700*1600*22004200 
General Feature
♦ Assembled by diesel engine and Brushless alternator. 
 Three filters as standard, fuel and water separator as optional.
♦ Radiator and fan with safety guard.
♦ Single bearing alternator IP 23, Insulation Class H.
♦ Heavy duty steel as base frame and 8hrs operation base fuel tank.
♦ Automatic control panel and 3 poles circuit breaker, internal cable.
♦ 12V or 24V battery, battery wires.
♦ Battery and float battery charger as standard supply scope.
♦ Fuel level indicator in meter and panel
♦ Optional soundproof canopy, ATS, synchronization panel, movable trailers. 
Genset Workshop

FAQ

1.Q: What is your MOQ of this item?

A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.

 

Customerized Fuel Tank

1.Volume: 500L, 1000L,1500L,2000L,3000L etc.

2.Plate steel construction

3.Fuel level meter

4.Fuel transfer systems

5.Double wall

6.Electric fuel pump 

7.Fuel level sensor (indicated on control module)

8.Fuel automatic filling system

9.Tank in genset base, top, built-in, seperately stand etc


CKD:Complete Knock Down Generator
Generator completely knocked down into parts without assembling. 
All items from following are seperately packed without connection.
 
SKD:Semi Knock Down Generator
Partially assembled generator. 
Part of the following items you choose will be assembled.
 

-----------------------------------------------------------------------------------------------MAINTENANCE---------------------------------------------------------------------------------------------

General Troubleshooting          

This section lists the generating set for some common fault, the reasons for the failure and determines the           
method of fault. General operators can determine their own fault and note, maintenance it according to the           
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.           
Please remember the following suggestions before repairing:           
- Make sure that study the failure carefully before any operation.           
- Repair with the easiest way and most commonly used method.           
- Find the exact causes of failure and completely solve the fault.     
   

1. Generator Sets          
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.           
(Some models of control panel installed only parts of the following warning indicator light)
IconIndicator LightReasonFault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary
Buyer review