• Overview
  • Details
  • More
Share Products Categories Channel Cart
1/5
Strong Medical Grade Polypropylene Lab Plastictri-Cornered Beakers 250ml Autoclacable图1Strong Medical Grade Polypropylene Lab Plastictri-Cornered Beakers 250ml Autoclacable图2Strong Medical Grade Polypropylene Lab Plastictri-Cornered Beakers 250ml Autoclacable图3

Strong Medical Grade Polypropylene Lab Plastictri-Cornered Beakers 250ml Autoclacable

Price $0.10
Min Order 100 Pieces  
Shipping from Shandong, China
Quantity
-+
Product details
50ml 100ml 250ml 400ml 800ml 1000ml
PP
No
Biologix
100 Pieces
CE FDA ISO
Changzhou, Jiangsu, China
3926909090
Product Description
Strong Medical Grade Polypropylene Lab PlasticTri-Cornered Beakers 250ml Autoclacable
 

Characteristic

* Features a tri-corner design that provides three dripless pouring spouts
* Six different sizes meet different needs
* Have good impact strength and are translucent and autoclavable
*Economical enough to be disposable and easy to clean and durable enough
 For Reuse

*Materials: Strong, medical-grade polypropylene
*Available in 50ml, 100ml, 250ml, 400ml, 800ml and 1, 000ml


Ordering Information
Cat #VolumeSterileUnit
93-005050mlNO25 Pieces/Sleeve, 4 Sleeves/Case
93-0100100mlNO25 Pieces/Sleeve, 4 Sleeves/Case
93-0250250mlNO25 Pieces/Sleeve, 4 Sleeves/Case
93-0400400mlNO25 Pieces/Sleeve, 4 Sleeves/Case
93-0800800mlNO25 Pieces/Sleeve, 4 Sleeves/Case
93-10001000mlNO25 Pieces/Sleeve, 4 Sleeves/Case

 


1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Buyer review
Loading review details...
Contact

Biologix Corporation

Audited Supplier13 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

Recommended for you