BASIC DESIGN DATA
| No. | Items | Working parameters | Remark |
| 1 | Steam turbine type | N1.5-1.25 | |
| 2 | Engine style | Q02 | |
| 3 | Rated power | 1500KW | |
| 4 | Rated speed | 6500-1500r/min | |
| 5 | Critical speed | 3950r/min | |
| 6 | Intake pressure | 1.25mpa | Absolute pressure |
| 7 | Intake temperature | 350ºC | |
| 8 | Steam intake capacity | 8.8t/h | |
| 9 | Steam consumption | 5.87kg/kw.h | |
| 10 | Exhaust pressure rated load | 0.0103mpa | |
| 11 | Layout type | Single layer | |
| 12 | Rotor structure | 1C 2 +7P | |
| 13 | Inlet/outlet diameter of main steam valve | 100/80×2mm | |
| 14 | Steam outlet diameter | 650 mm | |
| 15 | Weight of engine/rotor | 7.4/0.68t | |
| 16 | Max Weight for lifting | 1.6 t | |
| 17 | Operation floor standard height | 0 m | |
| 18 | Height from engine center to operation floor | 1050 mm | |
| 19 | Jacking gear | Manual | |
| 20 | Coupling manner for engine and gear box | Flat tooth style coupling | |
| 21 | Coupling manner for gear box and Power generator | Rigid coupling | |
| 22 | External dimension | 3650×2235×2112 mm | |
| 23 | Oil temperature for bearing | ≤65 | |
| 24 | Noise | ≤80dB | |
| 25 | Shaft vibration guarantee value | <0.03mm | |
| 26 | Circling cooling water temp () | Normal 27,Max.33 | |
| 27 | Circulating water pressure | 0.3-0.4Mpa /gauge pressure | |
| 28 | Generator model | 1FC6 566-4LA40 | |
| 29 | Generator output | 1500 KW | |
| 30 | Generator pressure | 400 V | |
| 31 | Environment temperature. | VDE40ºC | |
| 32 | Speed | 1500r/min | |
| 33 | Frequency | 50HZ | |
| 34 | Power factor | 0.8(dragging) | |
| 35 | Generator efficiency | 94.7% | |
| 36 | Isolation class | F/class | |
| 37 | Temperature rising class | F/ class | |
| 38 | Wiring style | 3 phase 4 line | |
| 39 | Cooling manner | Air cooling | |
| 40 | Noise level | A weighted sound level ≤105A) | |
| 41 | External dimension | See drawings |
| No. | Items | Working parameters | Remark |
| 1 | Steam turbine type | N1.5-1.25 | |
| 2 | Engine style | Q02 | |
| 3 | Rated power | 1500KW | |
| 4 | Rated speed | 6500-1500r/min | |
| 5 | Critical speed | 3950r/min | |
| 6 | Intake pressure | 1.25mpa | Absolute pressure |
| 7 | Intake temperature | 350ºC | |
| 8 | Steam intake capacity | 8.8t/h | |
| 9 | Steam consumption | 5.87kg/kw.h | |
| 10 | Exhaust pressure rated load | 0.0103mpa | |
| 11 | Layout type | Single layer | |
| 12 | Rotor structure | 1C 2 +7P | |
| 13 | Inlet/outlet diameter of main steam valve | 100/80×2mm | |
| 14 | Steam outlet diameter | 650 mm | |
| 15 | Weight of engine/rotor | 7.4/0.68t | |
| 16 | Max Weight for lifting | 1.6 t | |
| 17 | Operation floor standard height | 0 m | |
| 18 | Height from engine center to operation floor | 1050 mm | |
| 19 | Jacking gear | Manual | |
| 20 | Coupling manner for engine and gear box | Flat tooth style coupling | |
| 21 | Coupling manner for gear box and Power generator | Rigid coupling | |
| 22 | External dimension | 3650×2235×2112 mm | |
| 23 | Oil temperature for bearing | ≤65 | |
| 24 | Noise | ≤80dB | |
| 25 | Shaft vibration guarantee value | <0.03mm | |
| 26 | Circling cooling water temp () | Normal 27,Max.33 | |
| 27 | Circulating water pressure | 0.3-0.4Mpa /gauge pressure | |
| 28 | Generator model | 1FC6 566-4LA40 | |
| 29 | Generator output | 1500 KW | |
| 30 | Generator pressure | 400 V | |
| 31 | Environment temperature. | VDE40ºC | |
| 32 | Speed | 1500r/min | |
| 33 | Frequency | 50HZ | |
| 34 | Power factor | 0.8(dragging) | |
| 35 | Generator efficiency | 94.7% | |
| 36 | Isolation class | F/class | |
| 37 | Temperature rising class | F/ class | |
| 38 | Wiring style | 3 phase 4 line | |
| 39 | Cooling manner | Air cooling | |
| 40 | Noise level | A weighted sound level ≤105A) | |
| 41 | External dimension | See drawings |
- Technical requirements
- Steam turbine engine technical requirements
- Intake pressure Mpa (g): 1.25
- Intake temp. ºC: 350
- Condensing pressure Mpa (a):<0.0103
- Rated power KW: 1500
- Normal power KW: 1500
- Rated speed r/min: 6500-1500
- Normal speed r/min: 6500-1500
- Speed changing range : 80-105%
- Rated steam consumption guarantee value:5.87 kg/kw.h
- Noise guarantee value: <85db
- Shaft vibration guarantee value: <0.03mm
- Rotation direction: See from generator side, counter clockwise
- Circling cooling water temperature: Normal 27ºC, Max. 33ºC
- Driven motor(generator) parameter:
- Power: normal 1500kw, rated 1500kw
- Rotating speed: normal 1500r/min, rated 1500r/min
- Speed changing range: 80-105%
- Driven motor (generator) model:1FC6 566-4LA40
- Steam turbine engine
- Type: condensing impulse type
- Model: N1.5-1.25
- Design lifetime: 30 years.
- Under designing condition, continuous running time will be no less than 8000 hours.
- The steam turbine should satisfy the output and speed requirement of generator under various working conditions
- The steam turbine engine is multiple valves regulation.
- The layout type is single layer.
- Steam turbine engine technical requirements