Sanitary Stainless Steel Welded Aspetic Sample Valve (No. RY0103)图1Sanitary Stainless Steel Welded Aspetic Sample Valve (No. RY0103)图2Sanitary Stainless Steel Welded Aspetic Sample Valve (No. RY0103)图3Sanitary Stainless Steel Welded Aspetic Sample Valve (No. RY0103)图4Sanitary Stainless Steel Welded Aspetic Sample Valve (No. RY0103)图5Sanitary Stainless Steel Welded Aspetic Sample Valve (No. RY0103)图6

Sanitary Stainless Steel Welded Aspetic Sample Valve (No. RY0103)

Price $33.50
Min Order 1 Piece  
Shipping from Zhejiang, China
Quantity
-+
Product details
RY0103
Stainless Steel, AISI316L
Stainless Steel, AISI 304
Silicon
EPDM
1000kpa
EPDM-500kpa, Stainless Steel-1000kpa
Dry Steam: 121-134 Degree Celsius
NUOMENG, OEM
Carton, Plywood Case
3A, ISO, DIN, IDF, SMS
Wenzhou, China
7307290000
Product Description

Sanitary Stainless Steel Clamped Aspetic Sample Valve

 
Application:
The type of valve series is designed to use before and after doing sterilize treatment.

Open Valve: Sampling
To open valve can through rotary handle (can adjust type valve)or switch lever(open and close valve). When the central spindle and diaphragm have opened, the fluid can through sample.

Close Valve: Sterilization sample
Reverse operation handle, built-in-spring can close valve, meanwhile can keep the passageway through between the hosepipe, so that doing sterilization treatment. If need use the steam, advise the customer installed a small type of pressure to adjust valve in the outlet.
Standard Design:
The consisted parts of sterile sample valve included three parts: One valve body, one valve head and one piece diaphragm. Rubber diaphragm valve is put in the central spindle of valve head, and use as a continual central spindle.

Valve specification:
It can supple the valve specification to customer: First one use to treatment low viscosity material, such as water, beer, wine, fluid milk and so on; Second one use to trea high viscosity material, such as nutlet yoghourt, syrup, ice cream and so on.

Temperature
Max. Sterilization temperature, dry steam: 121~134° . Steam must be use dry, because the condensate water will damage the diaphragm. NUOMENG suggestes that customer should  replace diaphragm after 100 times sampling or sterilization.
 
No.RY0103ABCDEFGHI
9084.23543.8308.0741410



Packing:




Buyer review
Loading review details...
Contact

Wenzhou Nuomeng Technology Co., Ltd.

Audited Supplier19 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

You May Like
Home > Products > Industrial Equipment & Components > Valve > Other Valves & Parts