SSR-50
Oil Free
Rotary Vacuum Pump
Positive Displacement Pump
High Vacuum
Vacuum Pump
Dry
Roots Blower
Japan
Air Pump
Three Lobe
SSR
Export Standard Wooden Case
Roots Blower
China
8414599010
Product Description
Major Specifications of Type SSR-HB
Bore50 to 250A
Standard Accessories
Common Base
V-belt Cover
Blower Pulley, Motor Pulley
V-belt
Suction Silencer(With Air Filter)
Safety Valve
Pressure Gauge
Lubricating Oil
Anchor Bolt
Type SSR performance
The performance tables give the model number, bore, r. P. M., discharge pressure, air capacity and required power of the blower.
1 The air capacity in the tables is indicated in the standard suction state. The standard suction state herein mentioned is defined as the condition at 20oC temperature, 1.0332kgf/cm2 {101.3kPa} absolute pressure and 65% relative humidity.
2 The reference air capacity(0oC temperature and 1.0332kgf/cm2 {101.3kPa} absolute pressure is generally indicated in ) Nm3/min.
However, it may be converted into the standard air capacity by the following equation, if the suction pressure is equal,
QS=QN× 1.0732
Where QsStandard air capacity; And
QN: Reference air capacity;
3 The discharge air capacity can be converted into the standard air capacity by the following equation.
QsQd× [(1.0332+Pd)/1.0332]× (273+ts)/(273+td)
Where Qd: Discharge air capacity, inm3/min
Pddischarge pressure, inkgf/cm²
Ts: Suction temperature, inº C
Tddischarge temperature, inº C
4 According to the air capacity and discharge pressure as calculated abov e, the model number, bore, r. P. M. And required power can be found in the performance table.
5 The motor powers are indicated by color marking, and the motor powers to be used should be that indicated.
6 The choice is overlapped depending upon the type of blower, For reference, however, selection should be lower number blowers for the economy and higher number blowers for the sound level.


Bore50 to 250A
Air Capacity | 0.8-80m3/min |
Pressure | 0.1-0.8kgf/cm2 |
Motor Powe | 0.75-110kw |
Standard Accessories
Common Base
V-belt Cover
Blower Pulley, Motor Pulley
V-belt
Suction Silencer(With Air Filter)
Safety Valve
Pressure Gauge
Lubricating Oil
Anchor Bolt
Type SSR performance
SSR50 | Bore | Disxharge Pressure(kPa) | 9.8~58.8 |
50A | Inlet Flow Qs(m3/min) | 1.22~1.96 | |
SSR65 | Bore | Disxharge Pressure(kPa) | 9.8~58.8 |
65A | Inlet Flow Qs(m3/min) | 1.67~2.99 | |
SSR80 | Bore | Disxharge Pressure(kPa) | 9.8~58.8 |
80A | Inlet Flow Qs(m3/min) | 3.09~4.7 | |
SSR100 | Bore | Disxharge Pressure(kPa) | 9.8~58.8 |
100A | Inlet Flow Qs(m3/min) | 4.57~8.13 | |
SSR125 | Bore | Disxharge Pressure(kPa) | 9.8~58.8 |
125A | Inlet Flow Qs(m3/min) | 6.5~11.34 | |
SSR150 | Bore | Disxharge Pressure(kPa) | 9.8~58.8 |
150A | Inlet Flow Qs(m3/min) | 12.01~25.87 | |
SSR175 | Bore | Disxharge Pressure(kPa) | 9.8~58.8 |
175A | Inlet Flow Qs(m3/min) | 21.87~37.94 | |
SSR200 | Bore | Disxharge Pressure(kPa) | 9.8~58.8 |
200A | Inlet Flow Qs(m3/min) | 31.77~57.08 |
The performance tables give the model number, bore, r. P. M., discharge pressure, air capacity and required power of the blower.
1 The air capacity in the tables is indicated in the standard suction state. The standard suction state herein mentioned is defined as the condition at 20oC temperature, 1.0332kgf/cm2 {101.3kPa} absolute pressure and 65% relative humidity.
2 The reference air capacity(0oC temperature and 1.0332kgf/cm2 {101.3kPa} absolute pressure is generally indicated in ) Nm3/min.
However, it may be converted into the standard air capacity by the following equation, if the suction pressure is equal,
QS=QN× 1.0732
Where QsStandard air capacity; And
QN: Reference air capacity;
3 The discharge air capacity can be converted into the standard air capacity by the following equation.
QsQd× [(1.0332+Pd)/1.0332]× (273+ts)/(273+td)
Where Qd: Discharge air capacity, inm3/min
Pddischarge pressure, inkgf/cm²
Ts: Suction temperature, inº C
Tddischarge temperature, inº C
4 According to the air capacity and discharge pressure as calculated abov e, the model number, bore, r. P. M. And required power can be found in the performance table.
5 The motor powers are indicated by color marking, and the motor powers to be used should be that indicated.
6 The choice is overlapped depending upon the type of blower, For reference, however, selection should be lower number blowers for the economy and higher number blowers for the sound level.