Residential Commercial Industrial Use Ground Source Geothermal Heat Pump图1Residential Commercial Industrial Use Ground Source Geothermal Heat Pump图2Residential Commercial Industrial Use Ground Source Geothermal Heat Pump图3Residential Commercial Industrial Use Ground Source Geothermal Heat Pump图4Residential Commercial Industrial Use Ground Source Geothermal Heat Pump图5Residential Commercial Industrial Use Ground Source Geothermal Heat Pump图6

Residential Commercial Industrial Use Ground Source Geothermal Heat Pump

Price $1500.00
Min Order 1 Piece  
Shipping from Shanghai, China
Quantity
-+
Product details
One
50-70°C
Low-temperature Heat Pump
Ground-source
Multi-power Heat
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
CE, ISO9001, CCC, RoHS, SASO
Freestanding
Instant / Tankless
Stainless Steel
Green House, Hotels, Pool
7-300kw
7-300kw
55/60°c
-35degree
Shanghai Shenglin
Wooden Packing or Customized
Ctstomized
Shanghai, China(Mainland)
8418612090
Product Description


Commercial water heater heat pump series
MODELKFXR-010UIKFXR-018UIIKFXR-023UIIKFXR-036UIIKFXR-045UIIKFXR-070UIIKFXR-090UII
Heating mode Circulating
Ambient temp. rangeºC-15~+43ºC
Rated heating capacityKW10182336457090
COPW/W4.174.344.24.24.14.1
Rated power inputKW2.44.25.758.5710.71721.9
Max. running currentA17141624.8304558
Power supply/220V 1N~50Hz380v 3N~50Hz
IP code/IPX4
Safety function/High and low pressure protection, Overload protection, Temperature protection Power phase sequence protection, etc.
Refrigerant type/weight-/kgR407c/1.4R407c/2.7R407c/2.5R407c/2.0*2R407c/2.5*2R407c/7.5*2R407c/8.5*2
Compressor QTYPCS1112222
Compressor type/Scroll
Max. temp. outlet waterºC60
Water side heat exchanger type/Casing/high efficiency tankHigh efficiency tankCasingHigh efficiency tank
Air side heat exchanger type/Finned heat exchanger
Circulating waterpipe nozzleinchG3/4'' Internal threadG1'' Internal threadG1.2'' Internal threadG1.5'' Internal threadG1.5'' Internal threadDN100DN100
Outlet nozzleinchG3/4'' Internal threadG1'' Internal threadG1.2'' Internal threadG1.5'' Internal threadG1.5'' Internal threadDN100DN100
Circulating water flowinch1.723.13.956.27.7412.0415.48
Air out type/Top discharge
Fan motor QTYPCS1112222
NoisedB/(A)56565759656972
Machine dimension (W×D×H)mm750×690×870750×690×1070830×793×10841500×690×10701500×690×12702100×1100×20002100×1100×2000
Packing dimension (W×D×H)mm800×740×1000800×740×1200900×930×12001550×740×12001550×740×14002140×1200×20402140×1200×2040
Net weightkg110130150290350700800
Gross weightkg130150170330390750860
Remarks:
1. Test conditions: (DB/WB) 20°C/15°C, inlet water temperature 15°C, outlet water temperature 55°C.
2. Due to product improvement, above datas are subject to change without prior notice, please take the rating plate as standard.
Geothermal water to water heat pump series
ModelSFXKR-017IISFXKR-032IISFXK-015IISFXK-040II
Ambient temp. rangeºC-5~+25-5~+25-5~+25-5~+25
Power Supply/380V 3N~50Hz
Electric shock proof grade/Class IClass IClass IClass I
Protection grade/IPX4IPX4IPX4IPX4
Floor heating capacity/COPKW/-17/4.832/4.815/4.840/4.8
Rated heating capacity/COPKW/-16/4.131/4.113.7/4.136.5/4.1
Rated cooling capacity/COPKW/-15/528.5/513.0/534/5
Domestic Water heating capacity/COPKW/-16.5/4.428.5/4.4//
Floor heating input power.KW3.56.73.138.3
Rated heating input powerKW3.97.63.748.9
Rated cooling input powerKW35.72.66.8
Domestic water heating powerKW3.86.5//
Max. working currentA11.8231028
Refrigerant/weight-/kgR410a/2.5R410a/2.5×2R410a/2.5R410a/4.0×2
CompressorType/ScrollScrollScrollScroll
QuantityPCS1212
Water yieldL/h1400260012003200
Dimension (W×D×H)mm745×650×9601400×750×960745×650×9601400×750×960
Packing dimension(W×D×H)mm805×700×10201460×810×1020805×700×10201460×810×1020
Heat exchangerHeat source sideType/Plate heat exchanger or Tube in shell heat exchanger
Max/low outlet temperatureºC+25~-5 (Antifreeze solution with 25% ethylene glycol)
Water inlet sizeinchG1''A internal threadG1 1/2'' internal threadG1 internal threadDN40
Water flow volumem³/h1.42.61.23.2
Water pressure loss(Max.)kPa≤25≤30≤30≤30
Use sideType/plate heat exchanger or Tube in shell heat exchanger
Maximum/low outlet temperatureºC58/558/558/558/5
Nozzle sizeinchG1''A internal threadG1 1/2'' internal threadG1DN40

Domestic water side
Type/High-efficiency tank heat exchanger
Maximum/low outlet temperatureºC60606060
Rate Flowm³/h2.844.92.46.5
Nozzle sizeinchG1'' internal threadG1 1/2'' internal threadG1'' internal threadG1 1/2'' internal thread
a: Floor heating condition:Heat source side inlet temperature 0 ºC and use side inlet water temperature 30 ºC;
b: Rated heating condition:Heat source side inlet temperature 0 ºC and use side inlet water temperature 30ºC;
c: Rated cooling condition:Heat source side inletwater temperature is 25ºC and outlet water temperature is 30ºC; use side inlet water temperature is 12ºC and outlet water temperature is 7ºC.
*Due to product improvement, above datas are subject to change without prior notice, please take the nameplate as standard. 


Product Testing






Buyer review
Loading review details...
Contact

Shanghai Shenglin M&E Technology Co., Ltd.

Audited Supplier15 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

You May Like
Home > Products > Consumer Electronics > Water Heater & Components > Heat Pump Water Heater