• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
Pure Copper Conductor Medium Voltage Three Core XLPE Insulated Power Supply Cable图1Pure Copper Conductor Medium Voltage Three Core XLPE Insulated Power Supply Cable图2Pure Copper Conductor Medium Voltage Three Core XLPE Insulated Power Supply Cable图3Pure Copper Conductor Medium Voltage Three Core XLPE Insulated Power Supply Cable图4Pure Copper Conductor Medium Voltage Three Core XLPE Insulated Power Supply Cable图5Pure Copper Conductor Medium Voltage Three Core XLPE Insulated Power Supply Cable图6

Pure Copper Conductor Medium Voltage Three Core XLPE Insulated Power Supply Cable

Price $1.99
Min Order 500 Meters  
Shipping from Shanghai, China
Quantity
-+
Product details
YJY YJV WDZ-YJY WDZ-YJV
Construction, Industrial
Low and Medium Voltage Cable
DC & AC
XLPE
Round Wire
Bare Copper Wire
ISO, CCC, CE, RoHS
White/Black
500m
Copper
XLPE
PE
Shanghai Shenghua Cable Group
Wooden Steel Drum
1.1*1.1*0.98m
Shanghai, China
8544492100
Product Description

Product Name:YJY XLPE insulation LSOH Sheathed Flame retardant Power Cable

Product Description

1. Standard of XLPE Cable: According to GB12706( Equal to IEC60502)Also can do by the standard of ASTM, BS, DIN and AS/NZS or other standards as request.

2. Rated Voltage of XLPE Cable:

0.6/1KV 6/10KV;8.7/15KV;12/20KV;18/20KV;21/35KV;6/35KV

3. Construction of XLPE Cable:

Conductor: Copper or Aluminum

Insulation: XLPE

Inner sheath: PVC or PE

Armoured: Galvanized steel tape, Galvanized steel wire

Outer Sheath: PVC or PE

NO. of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.

Also can do according to the customer's request.

4. Characters of XLPE Cable:

a.Max  Long-time operating temperature of XLPE insulated cable is 90°C

b.Installing temperature of cable should not be less than 0°C

c.Max short-circuit temperature does not exceed 250°C, Not more than5 Sec.

d.Unable be laid without the limit of fall with enough mechanical pull, Single-core cable can not be laid in an iron tube or fixed by circled iron tools around cables

5. Description & Application of XLPE Cable:

TYPE

NAME

Main Application

CU core

AL core

 

 

YJV/YJY

YJLV/YJLY

XLPE insulated, PVC/PE sheathed power cable

For laying indoor, tunnel, canal and underground. Unable to bear external mechanical forces, but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated, steel tape armored, PVC/PE sheathed power cable

For laying indoor, tunnel, canal and underground.Able to bear external mechanical forces, but unable to bear the large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated, thin steel wire armored, PVC/PE sheathed power cable

For laying in the shaft, water underground will large difference of level. Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated, thick steel wire armored, PVC/PE sheathed power cable

For laying in water and seabed.Able to bear positive pressure and pulling force




6. Advantage:

a. Excellent electric and mechanical characteristics

b. Best Resistance chemical corrosion and heat-aging, environment stress and flame-retardant

c. Simple in structure, Convenient to use

d. Reduce costs.

British Standard MV cables Voltage Rating

BS6622 - standard British MV cable 6.35/11kV 19/33kV  

BS7835 - LSZH British MV cable 6.35/11kV 19/33kV  

European standard MV cables Voltage Rating 

N2XSY - single copper core XLPE insulated with PVC over sheath 6/10kV 12/20kV 18/30kV

N2XS2Y - single copper core XLPE insulated with PE over sheath 6/10kV 12/20kV 18/30kV

NA2XSY - single aluminum core XLPE insulated with PVC over sheath 6/10kV 12/20kV 18/30kV

NA2XS2Y - single aluminum core XLPE insulated with PE over sheath 6/10kV 12/20kV 18/30kV

N2XSEY - 3 copper core XLPE insulated with PVC over sheath 6/10kV

N2XS(F)2Y - single copper core XLPE insulated with water blocking powder and PE over sheath 6/10kV 12/20kV 18/30kV

N2XS(FL)2Y - single copper core XLPE insulated with water blocking powder and aluminum tape tightly bonded to PE sheath 6/10kV 12/20kV  

NA2XS(F)2Y - single aluminum core XLPE insulated with water blocking powder and PE over sheath 6/10kV 12/20kV 18/30kV

NA2XS(FL)2Y - single aluminum core XLPE insulated with water blocking powder and aluminum tape tightly bonded to PE sheath 6/10kV 12/20kV 18/30kV



Description:
CU/XLPE/LSOH, IEC 60331
IEC 60502, IEC 60227, IEC 60331, IEC 601034, IEC60754 GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001
CE, CCC, KEMA
Constructions
Conductor: Circular stranded copper conductor, conforms to IEC 60228 class 2
Insulation: XLPE/A
Inner Covering: LSOH
Sheath: LSOH , black
Note: Insulation color as per standards or customer requirement

Applications
Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable.
Standards
International: IEC 60502, IEC 60227 IEC 60331, IEC 601034
China: GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001
Other standards such as BS,DIN and ICEA upon request 


Technical data
Rated voltage: 18/30kV
Max. Conductor Temp.: normal (90ºC), short circuit no more than 5 s (the highest temperature of conductor shall no more than 250ºC )
Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0ºC
Min. Bending Radius: single core cable 20(d+D)±5%
                   Multi-core cable 15(d+D)±5%
Product NameYJY XLPE Insulation LSOH Sheathed Flame Retardant Power Cable
Model/StandardCU/XLPE/LSOH, IEC 60331, IEC 60502, IEC 60227, IEC 60331, IEC 601034, IEC 60754, GB/T 12706-91, GB306.1-2001, GB/T18380.3-2001, CE, CCC, KEMA
Conductor MaterialCircular stranded copper conductor, conforms to IEC 60228 class 2
Insulation MaterialXLPE/A
Inner CoveringLSOH
Sheath MaterialLSOH, black
Insulation ColorAs per standards or customer requirement
Rated Voltage0.6 kV
Max. Conductor TemperatureNormal: 90°C; Short circuit (5 seconds): Maximum conductor temperature not exceeding 250°C
Min. Ambient TemperatureCable should be preheated if ambient temperature is below 0°C
Min. Bending RadiusSingle-core cable: 20(d+D)±5%; Multi-core cable: 15(d+D)±5%