• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
Professional Manufacturer Low Voltage Twisted Aerial Concentric ABC Cable图1Professional Manufacturer Low Voltage Twisted Aerial Concentric ABC Cable图2Professional Manufacturer Low Voltage Twisted Aerial Concentric ABC Cable图3Professional Manufacturer Low Voltage Twisted Aerial Concentric ABC Cable图4Professional Manufacturer Low Voltage Twisted Aerial Concentric ABC Cable图5Professional Manufacturer Low Voltage Twisted Aerial Concentric ABC Cable图6

Professional Manufacturer Low Voltage Twisted Aerial Concentric ABC Cable

Price $100.00
Min Order 300 Meters  
Shipping from Jiangsu, China
Quantity
-+
Product details
ABC
Construction, Overhead, Underground, Industrial, Power Station, Telecommunication
Low and Medium Voltage Cable
DC & AC
Bare
PVC
Round Wire
Aluminum
ISO, CCC
ABC
Yunfeng
YUNFENG
Drum
3x120
China
7614900000
Product Description

 


Self-supporting LV-ABC Lines
Code: ABC 0.6/1kV, NFA2X, AsXS (n), 1-AES
Standards: HD 626 S1: 1996 Part 4-Section F,
PL WT92/K396, CSN 34761-4F
Construction: Phase Conductors: Aluminum conductors with XLPE insulation. 
Neutral Messenger: Aluminum conductors with XLPE insulation.
Application: Aerial Bundled Conductors are used
for tributary networks of power buildings
and their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.

Dimensions of phase conductors

Cross sectionConductor diameterThickness of insulationCore diameterCurrent carrying capacityBreaking load
(mm²)min.max.nom.min.min.(A*)(kN)
(mm)(mm)(mm)(mm)(mm)
164,65,11,21,007,8-2,60
255,66,51,31,0710,11074,17
356,67,51,31,0711,01325,78
507,78,61,51,2512,51658,45
709,310,21,51,2514,020511,32
9511,012,01,71,5016,1-15,30
12012,513,51,81,6017,6-20,00
15013,915,01,81,6018,8-25,00
* defined for ambient temperature of 35°C and max. conductor temperature of 80°C

Dimensions of neutral messenger conductors
Number of phase cores x cross sectionBundle diameter
+ public lighting conductorsapprox.
+ neutral cross section 
(mm²)(mm)
2 x 1615
2 x 2518
2 x 3520
4 x 1618
4 x 25 22
4 x 3525
4 x 5028
4 x 7032
4 x 70 + 1 x 3536
4 x 70 + 2 x 3540
4 x 9537
4 x 12040
4 x 120 + 2 x 3543
4 x 15044


LV-ABC Lines with Bare Neutral Messenger
Code: ABC 0.6/1kV,
Standards: HD 626 S1: 1996 Part 5-Section D,
 AMKA (SFS 2200)
Construction: Phase Conductors: Aluminum conductors with XLPE insulation. 
Neutral Messenger: Aluminum conductors 
Application: Aerial Bundled Conductors are used for
         tributary networks of power buildings and
their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.

Dimensions of phase conductors
Cross sectionConductor diameterThickness of insulationCore diameterCurrent carrying capacityBreaking load
(mm²)min.tolerancenom.min.min.max.(A*)(kN)
(mm)(mm)(mm)(mm)(mm) 
164,4±0,051,4-7,17,370-
255,9±0,021,4-8,39,195-
356,9±0,021,6-9,710,5115-
508,1±0,251,6-10,811,8140-
709,7±0,251,8-12,813,8180-
12012,8±0,302,0-16,217,4250-
* defined for ambient temperature of 25°C and max. conductor temperature of 70°C

Dimensions of neutral messenger conductors
Cross sectionConductor diameterThickness of insulationCore diameterCurrent carrying capacityBreaking load
(mm²)min.max.nom.min.min.max.(A*)(kN)
(mm)(mm)(mm)(mm)(mm)(mm)
255,9±0,02--5,56,3-7,4
356,9±0,02--6,57,3-10,3
508,1±0,25--7,68,6-14,2
709,7±0,25--9,210,2-20,6
9511,4±0,30--10,812,0-27,9

Dimensions of Cable Bundle
Number of phase cores x cross sectionBundle diameter
+ neutral cross sectionapprox.
(mm²)(mm)
1 x 16 + 2515
3 x 16 + 2522
4 x 16 + 2522
3 x 25 + 3526
4 x 25 + 3526
3 x 35 + 5030
3 x 50 + 7035
3 x 70 + 9541
3 x 120 + 9547



LV-ABC Lines with Insulated Neutral Messenger
Code: ABC 0.6/1kV,
Standards: HD 626 S1: 1996 Part 6-Section E,
 AMKA (SFS 2200)
Construction: Aluminum conductors with XLPE insulation. 
Application: Aerial Bundled Conductors are used for
         tributary networks of power buildings and
their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.
Dimensions of phase conductors
Cross sectionConductor diameterThickness of insulationCore diameterCurrent carrying capacityBreaking load
(mm²)min.max.nom.min.min.max(A*)(kN)
(mm)(mm)(mm)(mm)(mm) 
164,65,11,2-7,07,8--
255,86,31,4-8,69,4112-
356,87,31,6-10,010,9138-
507,98,41,6-11,112,0168-
709,710,21,8-13,314,2213-
9511,012,01,8-14,615,7258-
12012,013,11,8-15,616,7306-
15013,915,01,7-17,318,6344-
* defined for ambient temperature of 30°C and max. conductor temperature of 90°C
Dimensions of neutral messenger conductors
Cross sectionConductor diameterThickness of insulationCore diameterCurrent carrying capacityBreaking load
(mm²)min.max.nom.min.min.max(A*)(kN)
(mm)(mm)(mm)(mm)(mm) 
54,69,29,61,6-12,313,0-16,6
7010,010,21,5-12,913,6-20,5
9512,212,91,6-15,316,3-27,5
* defined for ambient temperature of 30°C and max. conductor temperature of 90°C
Dimensions of Cable Bundle
Number of phase cores x cross sectionBundle diameter
+ public lighting conductorsapprox.
+ neutral cross section 
(mm²)(mm)
3 x 25 + 54,630,0
3 x 35 + K x 16 + 54,633,0
3 x 50 + K x 16 + 54,636,0
3 x 70 + K x 16 + 54,637,5
3 x 70 + K x 25 + 54,6 40,0
3 x 70 + K x 16 + 7041,0
3 x 95 + K x 16 + 7044,0
3 x 120 + K x 16 + 7046,0
3 x 120 + K x 16 + 9547,0
3 x 150 + K x 16 + 7048,0
3 x 150 + K x 16 + 9549,0

Note: K number of public lighting conductors (K can be equal to 0, 1, 2, or 3)



Packing
Our wokshop

Range of Business: 

Cables
Low Voltage Power Cable: 0.6/1kV and Below PVC or XLPE Insulated Power Cable
Medium Voltage Power Cable: 6-35kV XLPE Insulated Power Cable
High Voltage (Extra-high Voltage) Power Cable: 66-500kV XLPE Insulated Power Cable
Bare Conductor and Electrical Wires

Cable Accessories
1~35kv cold shrinkable products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
1~35kv heat shrinkable Products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
66kv ~500kv Products
a. Porcelain Outdoor termination
b. Compound Sleeve Termination
c. GIS termination ( Assembly, plug-in Type )
d. Premould termination
e. Straight Joint/ Insulation Joint
f.   Branch Joint
g. Dry and Y shape Branch Joint


Why choose us? 
1. Export to many countries including Iraq, Tanzania and Australia and USA.
2. Best manufacturing and testing equipments imported from Germany, USA and Japan guarantee the best quality with competitive prices. 
3. Professional overseas team guarantees you best pre-and-after sale services.
4. Experienced engineers and workers for more than 20 years ensure the quality and customized products.
5. 5S Management to enhance the qualifications of staff and make better service for customers. 
6. Near Shanghai and Ningbo Port workshop makes it convenient to delivery on time.  
Buyer review
Loading review details...
Contact

Jiangsu Dongfeng Cable Co., Ltd.

Audited Supplier5 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

Recommended for you