Product Family XD 2-42R/T/RT
Adjust
Combination
Linear
Continuous
Automatic Control, Protection, Monitoring, Measurement
RoHS, CCC, ISO: 9001, CE
Used
Customized
Aluminum Alloy
8
8
2 Axis
Bd
XINJIE
Wooden Case
China
0101101010
Product Description
The functions are basically complete, in addition to the basic data processing functions, but also with pulse output, high-speed counting, pulse width modulation, frequency measurement and other special functions. Support the left extension ED, extension BD (16 points do not support), do not support the right expansion module, can meet the basic use needs of users.
The program capacity is 256KB , 1 / o sequence control
Maximum of 1 / O 60 points
Basic instructions 0.02 ~ 0.05us RS232, RS485
The X-NET fieldbus
2-way 100 KHz pulse output
3-way highway count (80K for single phase and 50K for AB phase)




The program capacity is 256KB , 1 / o sequence control
Maximum of 1 / O 60 points
Basic instructions 0.02 ~ 0.05us RS232, RS485
The X-NET fieldbus
2-way 100 KHz pulse output
3-way highway count (80K for single phase and 50K for AB phase)
Product Family XD 2- | 16R/T/RT | 24R/T/RT | 32R/T/RT | 42R/T/RT | 48R/T/RT | 60R/T/RT | |||
noumenon I/O | Total number of points | 24 | 32 | 42 | 48 | ||||
Number of input points | 8 | l4 | 18 | 24 | 28 | 36 | |||
Number of output points | 8 | 4 | 18 | 20 | 24 | ||||
maximum | /O check the number | 24 | 32 | 42 | 48 | ||||
High speed positioning | Ordinary pulse output | 2 Axis | 2 Axis | 2 Axis | 2 Axis | 2 Axis | 2 Axis | ||
Differential pulse output | |||||||||
High-speed input | Single-phase / AB mode | 3 Road | 3 Road | 3 Road | 3 Road | 3 Road | 3 Road | ||
input pattern | OC | OC | OC | OC | OC | OC | |||
Expanded ability | Right extension module | ||||||||
Left extension module | |||||||||
BD board | 2 | 2 | |||||||
suspend | external interrupt | ||||||||
timer interruption | 20 | ||||||||
Other interruptions | High-speed count interruption, pulse interruption | ||||||||
Communication function | Communication mouth | 2232,1485 | |||||||
protocol | Standard MODBUS ASCIl / RTU communication,, free format communication | ||||||||
Bus function | The X-NET fieldbus | ||||||||
PWM pulse-width modulation | support | ||||||||
frequency measurement | support | ||||||||
Accurate timing | 26 ETO to ET 25 (only) | ||||||||
Multi-station control | |||||||||
How the program is executed | Cycle scanning mode | ||||||||
Programming method | LD , ST, C , I L | ||||||||
Power failure to maintain | make use of F | ash ROM And lithium battery (3V button battery) | |||||||
Basic instruction processing speed | 0 . 02 ~ 0 . 05US | ||||||||
User program capacity (confidential download mode) | 256KB |