Kindsway III
Kindsway
Carton
Oxygen Analyzer
China
Product Description
The Kindsway III is a handheld oxygen analyzer/monitor capable of measuring the oxygen concentration from 0% to 100% in a sample gas. A OOM102-1 oxygen sensor outputs a voltage which is used by the PIGEON III to determine the concentration of oxygen based on a calibration at room air or 100% oxygen. The PIGEON III contains alarms that can be controlled by the user to set a maximum or minimum allowable oxygen concentration.


7.1 Base Unit Specifications
Measurement Range:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.0-100%
Resolution:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.1%
Accuracy and Linearity: . . . . . . . . . . . . . . . . . . . . . . . . . ±1% of full scale at constant
temperature, R.H.and pressure when calibrated at full scale Total
Accuracy: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3% Actual oxygen level over
full operating temperature range Response Time: ............ 90% of final value in
approximately 15 seconds at 23°C
Warm-up Time: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .none required
Operating Temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15°C - 40°C (59°F -
104°F)
Storage Temperature:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -15°C - 50°C (5°F -
122°F)
Atmospheric Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800-1013 mBars
Humidity:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-95%(non-condensing)
Power Requirements:. . . . . . . . . . . . . . . . . . . . . 3, AAA Alkaline batteries (3 X 1.5 Volts)
Battery Life: . . . . . . . . . . . . . . . . . . . . . . . . . . . . approximately 5000 hours in typical use
Low Battery Indication:. . . . . . . . . . . . . . . . . . . . . . . "LOW BAT" icon displayed on LCD
Sensor Type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . ENVITEC OOM102-1 galvanic fuel
cell Expected Sensor Life:. . . . . . . . . . . . . >1,000,000%
O2 Hours over 2 years in typical applications Alarm
System: . . . . . . . . . . . . . . . . . . . . . . . . . .high/low alarms,audiobuzzer
Low Oxygen Alarm Range: . . . . . . . . . . . . . . . . . 18%-99% (>1% lower than high
alarm)
High Oxygen Alarm Range: . . . . . . . . . . . . . . . . 18%-100% (>1% higher than low alarm)
Alarm Accuracy: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . exact to displayed alarm value
Dimensions:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84mm x 130mm x 31mm
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approximately 0.25 kg
7.2 Sensor Specifications
Type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . galvanic fuel sensor (0-100%)
Life: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 years in typical applications