Overhead Galvanized Steel Wire XLPE Insulated Aluminum Alloy AAC AAAC Conductor ACSR图1Overhead Galvanized Steel Wire XLPE Insulated Aluminum Alloy AAC AAAC Conductor ACSR图2Overhead Galvanized Steel Wire XLPE Insulated Aluminum Alloy AAC AAAC Conductor ACSR图3Overhead Galvanized Steel Wire XLPE Insulated Aluminum Alloy AAC AAAC Conductor ACSR图4Overhead Galvanized Steel Wire XLPE Insulated Aluminum Alloy AAC AAAC Conductor ACSR图5Overhead Galvanized Steel Wire XLPE Insulated Aluminum Alloy AAC AAAC Conductor ACSR图6

Overhead Galvanized Steel Wire XLPE Insulated Aluminum Alloy AAC AAAC Conductor ACSR

Price $1.50
Min Order 500 Meters  
Shipping from Henan, China
Quantity
-+
Product details
6Al/1Alloy
Bare
Stranded
Overhead
Aluminum
Bare
Bare
Round Wire
Overhead Cable
ISO9001, CE, CCC
Jinshui
JINSHUI
Drum
1.1*1.1
Zhengzhou Henan
4107961636
Product Description
Standards and Scope of Application
The products are used for aerial electric power transmission according to the standard ASTM , IEC , BS , CSA , NFC , and so on

Specific property for using
1.The permissible long-time operating temperature for aerial conductor is 70 C 
2.For long-span application in harsh environment such as heavy icing , the biggest stress of the cable at the lowest point on the span curve shall not exceed 60% of its breaking load.
3.When connecting conductors , the conductor near the connecting tube can't be prominent. Otherwise , the force on the operating conductors will be unbalanced after connectors are pressed . The connecting tube should be plated by moistureproof paint in order to avoid corrosion.
4.In order to meet conductor-to-earth or conductor-to-building distance requirement during installation , the conductor stress can be 10%~15% higher than its permissible normal tension .

DESCRIPTION
Very good strength/weight ratio . Highly resistant to sorrosion .

STANDARDS
Construction as per ASTM , IEC , BS , DIN , CSA , NFC ,and so on.

APPLICATION
Used as bare overhead transmission cable and as primary and secondary distribution cable . A good strength-to-weight ratio makes ACAR applicable where both amacity and strength are prime considerations in line disign ; with equal weight , ACAR offers higher strength and ampacity than ACAR . 