Ophthalmic Phacoemulsification Phaco Emulsifier Machine图1Ophthalmic Phacoemulsification Phaco Emulsifier Machine图2Ophthalmic Phacoemulsification Phaco Emulsifier Machine图3Ophthalmic Phacoemulsification Phaco Emulsifier Machine图4Ophthalmic Phacoemulsification Phaco Emulsifier Machine图5Ophthalmic Phacoemulsification Phaco Emulsifier Machine图6

Ophthalmic Phacoemulsification Phaco Emulsifier Machine

Price $12500.00
Min Order 1 Piece  
Shipping from Shanghai, China
Quantity
-+
Product details
RGW-Z0331
Customized
CE, FDA, EEC, ISO13485
Large
Rgw
High Quality
Online Technical Support
3 Years
Shanghai, China
Class II
GB/T18830-2009
RGW
Carton Box
N/M
China
Product Description
 

Specifications: Phaco Emulsification
Phaco Emulsification Frequency: 40KHz±20%;
U/S Handpiece Top End Vibration Accuracy: Max. 120μm±20%;
Stimulating Power Range: 0~100%, soft keyboard input or adjustable stepping, Step: 1%;
Pulse Frequency:1Hz~99Hz, soft keyboard input or adjustable stepping, Step:1Hz; Effective emulsification time:1%~99% (≥5ms);
Soft Keyboard Input or Adjustable Stepping: Step:1%;
display accuracy: ≤±10%;
Burst Time: 5ms~100ms, soft keyboard input or adjustable stepping;
Step:1ms; display accuracy:≤±10%;
Max. Vacuum:66.7kPa (500mmHg);
display accuracy: ≤±15%;
Max. Flow Rate: 40 ml/min;
display accuracy: ≤±20%

High-Frequency Cautery
Rating Frequency:1MHz±20%;
Max. Output Power: 10W±20% (200Ω Load);
Output Adjustable Range: 0~100%, soft keyboard input or adjustable stepping, Step: 1%;
display accuracy: ≤±20%

Vitrectomy
Cutting Frequency: single mode or (20~600) times/min, soft keyboard input or adjustable stepping, step of 5 times/min, display accuracy: ≤ ±15%; Max. Vacuum: 66.7kPa (500mmHg), display accuracy: ≤ ±15%;
Maximum Flux Rate: 40 ml/min, display accuracy: ≤ ±20%

Irrigation/Aspiration
Vacuum Range: 1mmHg~500mmHg;
Flow Rate: 1 ml /min~40 ml /min;
Max. Vacuum: 66.7kPa (500mmHg), display accuracy: ≤ ±15%;
Max. Flow Rate: 40 ml/min, display accuracy: ≤ ±20%;
Reflux Rate: 20 ml/min±20%

 
High-Frequency Cautery
Rating Frequency:
1MHz±20%;
Max. Output Power:
10W±20% (200Ω Load);
Adjustable Range
0~100%,
Vitrectomy
Vacuum Range:
1mmHg~500mmHg
Flow Rate
1 ml /min~40 ml /min;
Max. Flow Rate
40 ml/min, display accuracy
Phaco Emulsification
Phaco Emulsification Frequency:
40KHz±20%
Pulse Frequency
1Hz~99Hz,
display accuracy
: ≤±15%
Effective emulsification time
1%~99% (≥5ms);
Burst Time
5ms~100ms
 
 
 
 
 
 
 
 