• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
Online Monitor for Cadmium Content in Wastewater图1Online Monitor for Cadmium Content in Wastewater图2Online Monitor for Cadmium Content in Wastewater图3Online Monitor for Cadmium Content in Wastewater图4Online Monitor for Cadmium Content in Wastewater图5Online Monitor for Cadmium Content in Wastewater图6

Online Monitor for Cadmium Content in Wastewater

Price $7000.00
Min Order 1 Set  
Shipping from Jiangsu, China
Quantity
-+
Product details
AG-TCd07
1 Year
1 Year
Digital
Water Quality Monitor
Non Portable
CE
Cadmium
0-5mg/L OEM
5%
Less Than 5%
30min
RS-232, 4-20mA, RS-485
JUGE or OEM
Carton
1500*500*450mm
Nanjing, China
Product Description
Product Description
Online Monitor for Cadmium Content in Wastewater

>>Application

This method is applicable to wastewater with cadmium concentrations within the range of 0-5 mg/L.


>>Technical parameters

1. Measurement Method: Dithizone spectrophotometric method
2. Measurement Range: 0-2 mg/L, OEM 0-5mg/L
3. Accuracy: ≤±10%
4. Repeatability: ≤±5%
5. Measurement Cycle: Minimum cycle is 30 minutes; color development time can be adjusted flexibly between 5-30 min based on environmental conditions.
6. Sampling Cycle: Adjustable time interval (10-9999 min) or on-the-hour measurement mode.
7. Calibration Cycle: Adjustable at any interval from 1-99 days.
8. Maintenance Cycle: ≥168 hours, with each maintenance lasting ~1 hour.
9. Reagent Consumption: <0.50 CNY per sample.
10. Outputs: RS-232, 4mA-20mA, RS-485.
11. Environmental Requirements: Temperature-controlled indoor environment (recommended: 5-40°C); humidity 45%-85%.
12. Power Supply: AC 220±10% V, 50±1% Hz, 5A.
13. Dimensions: Height 1500 × Width 500 × Depth 450 mm.
14. Additional Features:

  • Data retention during abnormal alarms or power outages.
  • Touchscreen display and command input.
  • Automatic discharge of residual reactants and resumption of operation after power restoration or system reset.

>>Feature

Unique Design: This product features a distinctive design that ensures lower failure rates, reduced maintenance requirements, minimal reagent consumption, and higher cost-effectiveness compared to similar products.

  1. Selector Valve Assembly:

    • Enables flexible reagent sampling timing and diverse channel configurations.
    • Minimizes dead volume for easy maintenance and extended service life.
  2. Micro-Dosing Unit:

    • Utilizes a visual photoelectric system for precise reagent measurement, eliminating quantitative errors caused by peristaltic pump tube wear.
    • Achieves accurate micro-dosing with 0.7 mL per dose, significantly reducing reagent usage.
  3. Sample Introduction Unit:

    • Employs a peristaltic pump with negative pressure suction, creating an air buffer zone between reagents and the pump tube to prevent corrosion.
    • Simplifies and enhances flexibility in reagent mixing.
  4. Sealed Digestion Unit:

    • Operates under high-temperature and high-pressure conditions to accelerate reactions.
    • Eliminates corrosion risks from volatile gases in open systems.
  5. Reagent Tubing:

    • Uses imported modified PTFE (polytetrafluoroethylene) transparent tubing with an inner diameter >1.5 mm to minimize clogging by particulate matter in water samples.

>>Analytical Principle

The aqueous sample undergoes hot-block digestion (150°C ±5°C) with concentrated HNO<sub>3</sub> (1:1 v/v) followed by pH adjustment using ammonium citrate buffer. In alkaline medium (pH 10.0 ±0.1 maintained by NH<sub>4</sub>OH/NH<sub>4</sub>Cl buffer) with dithizone as the chromogenic agent, cadmium ions form a crimson-red Cd-dithizonate complex exhibiting maximum absorbance at 518 nm (ε = 8.5×10<sup>4</sup> L·mol<sup>-1</sup>·cm<sup>-1</sup>). A microprocessor-controlled portable photometer (e.g., Hach DR1900) quantifies cadmium concentration through dual-wavelength measurement (518 nm sample vs 650 nm reference), with calibration curves validated per EPA Method 200.7 requirements (linear range: 5-200 μg/L, LOD 1.5 μg/L).

 
Company Profile


>>OEM Solutions & Service Advantages
We provide OEM customization services. Contact us to discuss tailored product solutions. 

1) 12-hour response guarantee for all inquiries;
2) Premium quality with industry-competitive pricing;
3) Dedicated post-purchase support system;
4) OEM/ODM compatibility;
5) Certified safety equipment specialists with expert engineering team.

 

>>FAQ
Q: Can I request a single sample unit for quality assessment?
A: Absolutely. We strongly advise sample evaluation before mass ordering.

 

Q: Could I obtain your product catalog and MOQ pricing details?
A: Our complete product portfolio is available digitally. Please browse our website for model specifications or email specific requests.

 

Q: What pricing advantages apply for large quantity orders?
A: Submit your complete requirements (product model, quantities, quality standards, branding specifications, payment terms, and logistics details) for optimized bulk pricing.

 

>>Certifications
>>Shipping

Buyer review
Loading review details...
Contact

Nanjing Juge Environmental Technology Co., Ltd.

Audited Supplier1 Year
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

You May Like
Home > Products > Instruments & Meters > Analysis Instrument > Liquid Analyzer