CHW-MT7B
Skin Graft Mesher
Burns Surgical
Steel
ISO13485
Burn Patients
Skin Graft Mesher
8.5kg
9.5kg
39*31*31cm
ICLEAR
Carton
China
Product Description
Multi-Use Dermatome Skin Grafting Machine Burns Surgical Portable Skin Graft Mesher
CHW-MT7B


Features:
The design of this machine is the technology that makes various ratio reticular skin grafts perfectly by one machine. There is no need to change the expansion roller and different ratio skin graft carrier. The width of the treated skin graft can be much larger than traditional skin graft meshes, and the length is unlimited.
1. We suggest autoclave sterilization or low-temperature plasma sterilization.
2. The warranty period is one year. After a year, a certain amount of maintenance fees will be paid each year for a continuous warranty.
Components & Basic parameters:
Standard components:
1 mainframe
1 continuous feed roller
1 expansion roller
1 ratchet handle
2 boxes of skin graft carriers
Technical Parameters
1.Product Name: Skin Graft Mesher
2.Machine Model: CHW-ET7B
3.Machine Function: Make reticular skin graft.
4.Function Specifications: ratio of reticular skin graft from 1:1 to 1:5.5, even larger.
5.Distance between the two hole:2mm.
6. Function Realization Method: adjust and make different expansion ratio reticular skin by the adjustable expansion roller without changing different expansion rollers or selecting different ratio pattern carriers, simple operation.
7.Specification of skin graft can be processed:
Width: ≥130mm Length: Unlimited Thickness: Unlimited
8.Operation Method of Machine: Manual
9.Sterilization Method: pre-vacuum and gravity displacement steam sterilization or low-temperature plasma sterilization, etc.
10.Comsumables: we suggest a skin graft carrier for single use.
11. The whole device and rollers are anti-corrosive, the rollers are sharp and will not be rusty.
12.Non-die roller design, longer lifetime, a single blade can be replaced, lower maintenance cost.
Precautions and safety warnings:
1.This device can only be used by a trained or professional surgeon.
2.In order to ensure the accuracy of the expansion roller, please replace it every 1000 times.
3.The blades are very sharp, avoid contact with hands directly.
4. Please just use our company's carriers, otherwise, it will damage the expansion roller.
Safety precautions:
1.Please select the appropriate skin graft carrier according to the clinical demand.
2.After using the machine, the expansion roller should be removed incorrect way.
3.Dispose the carrier according to disposable medical product regulations.
4.The machine must not be soaked in saline solution.
Warnings:
1.The machine should be placed in a relatively dry environment at room temperature.
2.Handle gently and do not collide.
Clean steps:
After using the machine, it should be cleaned immediately. The machine should not be soaked in liquid for a long period of time. It should be scrubbed with a cleanser dampened with gauze or a soft cloth, or it can be scrubbed with a small brush. After cleaning, store all parts in a dry and ventilated environment. Do not place the machine with liquid.
Sterilization methods:
Various sterilization methods are applicable, such as pre-vacuum and gravity displacement steam sterilization or low-temperature plasma sterilization, etc.




Related Recommends

Company Information

CHW-MT7B



The design of this machine is the technology that makes various ratio reticular skin grafts perfectly by one machine. There is no need to change the expansion roller and different ratio skin graft carrier. The width of the treated skin graft can be much larger than traditional skin graft meshes, and the length is unlimited.
1. We suggest autoclave sterilization or low-temperature plasma sterilization.
2. The warranty period is one year. After a year, a certain amount of maintenance fees will be paid each year for a continuous warranty.
Components & Basic parameters:
Standard components:
1 mainframe
1 continuous feed roller
1 expansion roller
1 ratchet handle
2 boxes of skin graft carriers
Technical Parameters
1.Product Name: Skin Graft Mesher
2.Machine Model: CHW-ET7B
3.Machine Function: Make reticular skin graft.
4.Function Specifications: ratio of reticular skin graft from 1:1 to 1:5.5, even larger.
5.Distance between the two hole:2mm.
6. Function Realization Method: adjust and make different expansion ratio reticular skin by the adjustable expansion roller without changing different expansion rollers or selecting different ratio pattern carriers, simple operation.
7.Specification of skin graft can be processed:
Width: ≥130mm Length: Unlimited Thickness: Unlimited
8.Operation Method of Machine: Manual
9.Sterilization Method: pre-vacuum and gravity displacement steam sterilization or low-temperature plasma sterilization, etc.
10.Comsumables: we suggest a skin graft carrier for single use.
11. The whole device and rollers are anti-corrosive, the rollers are sharp and will not be rusty.
12.Non-die roller design, longer lifetime, a single blade can be replaced, lower maintenance cost.
Precautions and safety warnings:
1.This device can only be used by a trained or professional surgeon.
2.In order to ensure the accuracy of the expansion roller, please replace it every 1000 times.
3.The blades are very sharp, avoid contact with hands directly.
4. Please just use our company's carriers, otherwise, it will damage the expansion roller.
Safety precautions:
1.Please select the appropriate skin graft carrier according to the clinical demand.
2.After using the machine, the expansion roller should be removed incorrect way.
3.Dispose the carrier according to disposable medical product regulations.
4.The machine must not be soaked in saline solution.
Warnings:
1.The machine should be placed in a relatively dry environment at room temperature.
2.Handle gently and do not collide.
Clean steps:
After using the machine, it should be cleaned immediately. The machine should not be soaked in liquid for a long period of time. It should be scrubbed with a cleanser dampened with gauze or a soft cloth, or it can be scrubbed with a small brush. After cleaning, store all parts in a dry and ventilated environment. Do not place the machine with liquid.
Sterilization methods:
Various sterilization methods are applicable, such as pre-vacuum and gravity displacement steam sterilization or low-temperature plasma sterilization, etc.




Related Recommends

Company Information

FAQ
> if the machine broke after a period of use, can I return it back and get a refund? iClear HealthCare has a secure procedure to do the product return and repair, please check our service policy for more information. |
> I have NO experience buying medical stuff in China. Is the quality good? There are multiple options in China for medical equipment, iClear HealthCare aims to provide high-quality products at a competitive price. |
> How long will it take to reach me after the payment? By Express, it takes 5-7 working days to arrive; By Air, 3-4 days to the international airport; By Sea, around 25-55 days to the seaport. |
>> Can you help set up a clinic or provide complete equipment for hospital projects? We have a series of complete solutions for clinics and hospital equipment setup. iClear HealthCare has helped set up several clinics and 2 hospitals in East Asia, African, and Saudi and supply all the medical equipment. These projects have saved a lot of time, money, and energy for our customers. |