Micro Inverter Solar Off grid System

This SPF 5000 ES inverter is an off-grid PV inverter with a 230VAC output voltage for backup power and self-consumption applications with a maximum PV input voltage of up to 450VDC. It can also work without batteries, saving system investment costs.
This is a multifunctional off-grid solar inverter that integrates MPPT solar charge controller, high frequency pure sine wave inverter and UPS function module, ideal for off-grid backup power and self-consumption applications. This inverter can work with or without batteries.
| BATTERY | Battery Voltage | 48VDC |
Battery Type | Lithium/Lead-acid | |
INVERTER OUTPUT | Rated Power | 5000VA/ 5000W |
| Parallel Capability | Yes, 6 units maximum | |
AC Voltage Regulation (Battery Mode) | 230VAC ± 5% @ 50/60Hz | |
| Surge Power | 10000VA | |
| Efficiency (Peak) | 93% | |
Waveform | Pure sine wave | |
Transfer Time | 10ms typical, 20ms Max | |
SOLAR CHARGER | Maximum PV Array Power | 6000W |
| MPPT Range @ Operating Voltage | 120VDC ~ 430VDC | |
Number of Independent MPP Trackers/Strings Per MPP Tracker | 1/1 | |
| Maximum PV Array Open Circuit Voltage | 450VDC | |
Maximum Solar Charge Current | 100A | |
AC CHARGER | Charge Current | 80A |
| AC Input Voltage | 230 VAC | |
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) ; 90-280 VAC (For Home Appliances) | |
Frequency Range | 50Hz/60Hz (Auto sensing) | |
PHYSICAL | Protection Degree | IP20 |
Dimension (W/H/D) | 330/485/135mm | |
Net Weight | 12kgs | |
OPERATING ENVIRONMENT | Humidity | 5% to 95% Relative Humidity(Non-condensing) |
Altitude | <2000m | |
Operating Temperature | 0°C - 55°C | |
Storage Temperature | -15°C - 60°C |
- Integrated MPPT charge controller
- Equalization charging function.
- Work with battery or without battery.
- Maximum PV input voltage up to 450VDC.
- Configurable grid or solar input priority.
- Optional WIFI/ GPRS remote monitoring.
- Support parallel operation for capacity expansion up to 30kW.
- PV and Grid power the load jointly if PV energy unsufficient.
- Flexibly schedule the Inverter charging and discharging time.
Do not mount the inverter on flammable construction materials.Mount on a solid surface.
The recommended installation position is to be adhered to the wall vertically.
Make sure to keep a certain distance from other objects and surfaces to ensure adequate heat dissipation and enough room to remove wires.



| Number | Product Name |
| 1 | LCD display |
| 2 | Status indicator |
| 3 | Charging indicator |
| 4 | Fault indicator |
| 5 | Function buttons |
| 6 | AC input |
| 7 | WiFi/GPRS communication port |
| 8 | USB communication port |
| 9 | BMS communication port (support CAN/RS485 protocol) |
| 10 | RS485 communication port (for expansion) |
| 11 | Dry contact |
| 12 | PV input |
| 13 | Power on/off switch |
| 14 | Battery input |
| 15 | Parallel communication ports |
| 16 | Current sharing ports |
| 17 | AC output |
| 18 | Circuit breaker |
Xiamen Wintop New Energy Tech. Co. Ltd was established in 2016, it is a high-tech enterprise that integrates R&D, production and marketing of Solar Mounting System for residential, commercial and utility scale customers.