Med Solas 60min Compressed Air Breathing Apparatus for Ship图1Med Solas 60min Compressed Air Breathing Apparatus for Ship图2Med Solas 60min Compressed Air Breathing Apparatus for Ship图3Med Solas 60min Compressed Air Breathing Apparatus for Ship图4Med Solas 60min Compressed Air Breathing Apparatus for Ship图5Med Solas 60min Compressed Air Breathing Apparatus for Ship图6

Med Solas 60min Compressed Air Breathing Apparatus for Ship

Price $400.00
Min Order 1 Set  
Shipping from Chongqing, China
Quantity
-+
Product details
RHZK
CCS, Ec(Dnv-Gl)
Solas
5L, 6L, 6.8L
Carbon Steel, Carbon Fiber
30MPa
More Than 10 Years
GH
Carton
China
Product Description
This MED SOLAS 60Min Compressed Air Breathing Apparatus For Ship are self-contained open breathing apparatuses. This series of products, which are ideal personal breathing protectors for the fireman and emergency rescuer, are widely used in such sectors as fire fighting, chemical industry, shipping, petroleum, smelting, electricity, warehouse, lab, mine, for the firemen and emergency rescuers to perform effectually rescue and relief work under the conditions of heavy smoke, poison gas, steam and hypoxia, etc.
Instruction

Self-contained Breathing Apparatus (SCBA) Type: RHZK6.8/30

The SCBA is designed for protecting:
  1. Toxic particles and aerial fog
  2. Toxic gases
  3. The oxygen concentration is less than 17%
  4. The smog caused by fire disaster
 
  1. Production diagram and technical parameters
    1. Product diagram
 
NO.ItemNo.Item
1Gas cylinder6Pressure regulator
2Strip7Quack filling connector
3High-pressure pipelines8Full face mask
4Pressure gauge with whistle9Air supply valve
5Harness10Cylinder valve
 
    1. Technical parameters
 
1Gas cylinderCapacity6.8L,carbon fiber composite material
Working pressure30MPa
2Pressure regulatorAir supply>310L/min
Output pressure0.6~0.9MPa
3Safety valve opening pressureOpen in 1~1.6MPa
4Pressure with alarm whistleAlarm pressure5.5±0.5MPa
Sound level90db
5Respiratory resistance<980Pa
6Service time60min
7Package size75*30*47cm
8Weight (net)10.00kg
Weight (with plastic case and packing carton)16.00kg
  1. Harness and belt 

Completely in accordance with human body engineering design,shape the back curve of joint human body completely,contact area bigger,wear comfortable.By straps can easily adjust the back contact height and position of joint human body back.Back frame made of lightweight polypropylene materials,impact resistance and corrosion.Overall injection,disinfection, convenient cleaning.The lateral parts without actuate angle,will not cause harm to human anti-slip fabrics and woven belt,wearing more comfortable.Belts buckles made of durable nylon materials, convenient adjustment.Braces fabric for flame retardant material.
 
  1. Pressure gauge with alarming whistle 

Main performance

Pressure gauge reading: 0-40MPa, with safety opening.
With fluorescence function, the area of 0-5MPa marked in red. Working pressure: 30MPa

The thimble in the alarm whistle is fixed in the spring by the high pressure air, which is transported by pressure regulator and high-pressure pipelines, when opening the valve of gas cylinder. The thimble is for sealing, it can prevent the medium-pressure air into the alarm whistle and hence, the whistle won't alarm.
When the pressure in the gas cylinder is below 5.5±0.5MPa,the thimble detach the sealing position under the action of the string, the medium-pressure air enter into the alarm whistle at the speed of 5 L per minute. And then, the whistle alarms.

 

Work function

Work pressure of the alarm whistle: 5.5±0.5MPa The whistle will alarm until the air exhaust.
Air consumption: 5 L/ minute Sound level: 90db
Frequency: 3800HZ
 
  1. Air supply valve
The air supply valve weights light, has compact structure and is made of the fire impact-resistant material. It can fast connect with the face mask through the string button and fast interface. The air supply valve connects with the pressure gauge through the medium-pressure pipeline. When it occurs the disordered breathing on the user, press the red "ON" button and the air supply valve will increase the amount of gas automatically to 450L per minute (the air supply valve will reach this gas amount within tenths of a second)
The maximum amount of gas : 450L/minute

 
  1. Pressure regulator 
Whatever the change of air pressure in the gas cylinder and the user's breathing frequency, the pressure regulator can provide a stable output pressure. The black sealed cap guarantees the authorized maintenance of pressure regulator, it can't be removed privately, otherwise, the person who removes the cap should suffer the consequence.

Mainly parts connected with the pressure regulator:
  1. One or two gas cylinder
  2. Medium-pressure pipeline, transporting the air to the air supply valve
  3. High-pressure pipeline, connecting with the pressure gauge
  4. Technical specification
The maximum input pressure: 30MPa Output pressure: 0.7±0.05MPa
Opening pressure of the safety valve: 1.1±0.2MPa
Working temperature: -30ºC-+60ºC (According to the standard of EN137) Type: Dynamic balance

Warning: The pressure regulator only can be maintained by designated person, they are our company's specialist and the maintenance personnel, or the person who has the professional training and get the authorized by our company.


6. Full face mask
        
 Adjustable, comfortable to wear
Wide view
Connected with the air supply valve through the fast interface
Novel one-way exhalation valve to reduce the breathing resistance
There is tightening belt and quick clip, so the headband is easy to be adjusted
With mouth and nose mask, to reduce the carbon dioxide content

The mask is anti-fog


7. Gas cylinder

It is composed of high-strength aluminum alloy liner and fully wrapped carbon fiber composite material, which is high strength, light weight.
Service time: It depends on the amount of compressed air and the air consumption of the user and the air consumption depends on the user's work nature.
Work nature Air consumption (L/Min)
Rest 10-15
Mild activity 15-20
Light work 20-30
Intensity work 30-40
High-intensity work 45-55
Work for a long time 50-80
Vigorous activity (few minutes) 100

The amount of breathable air in the gas cylinder
The user can get the value by calculating the product of the volume of gas cylinder and working pressure.
For example: the working pressure of a 6.8L gas cylinder at 30MPa, the air volume is 6.8*30*10=2040L
When the user is in intensity work, the theory time of this gas cylinder is:
The volume of breathable air (L) 2040 (=68mins)
The volume of air consumption (L/Min) 30

This calculation method doesn't consider the purity of air, so it needs add a 0.9 coefficient to correct. The actual air volume in the gas cylinder is: 2040*0.9=1836L. According to this calculation method, the actual use of time is 61.2 minutes. The user can roughly calculate the working time before or in the progress of using the gas cylinder.



8. Cylinder valve

Working pressure: 30Mpa
Outlet Connection: DIN G5'/8
Internal thread Inlet Connection: M18*1.5
With safety control blasting
Excess flow valve inside

Specification

Volume of the gas cylinder6.8L
Cylinder materialCarbon fiber composites
Service time≥60mins at 30L/min
Working pressure30MPa
Hydrostatic pressure45MPa
Overall weight9kg(air not included)
GasCompressed air
StandardCE: EN137
 