Type K
Bare
Solid
Heating
Chromel Alumel
PVC
Round Wire
Temperature Measurement
ISO9001, CE, RoHS
Huona
0.3/0.5/0.8/1.0/1.2/1.6/2.0/2.5/3.2mmm
Bright/ Oxidized Thermocouple Wire
I/II/III
≥390
Chromel Alumel Thermocouple Wire
Chromel
Alumel
Round/Flat
Tc Wire / K14 Thermocouple Wire
Type K
Small Order Accepted
Yes
Syen
HUONA
Wooden Cases or Cartons
Diameter 0.03mm-4mm
Shanghai
9025900090
Product Description
2x0.711mm High Temperature Type K With Silica Fiberglass Insulated Thermocouple Cable
Thermocouple wire allows temperatures to be measured electronically. A typical thermocouple construction consists of a pair of dissimilar metals that are electrically joined together at the sensing point and connected to a voltage measuring instrument at the other end. When one junction is hotter than the other, a thermal "electromotive" force (in millivolts) is produced that is roughly proportional to the difference in temperature between the hot and cold junctions.
NiCr-NickelSi (Type K) thermocouple wire finds the widest use in all basemetal thermocouple, at temperature above 500 °C.
Type K thermocouple wire has strong resistance to oxidation than other base metal thermocouples. It has high EMF against Platinum 67, excellent temperature accuracy, sensitivity and stability, with a low cost. It is recommended for oxidizing or inert atmospheres, but cannot be used directly in the following cases:
(1) Alternatively oxidizing and reducing atmosphere.
(2) Atmosphere with sulphur gases.
(3) Long time in vacuum.
(4) Low oxidizing atmosphere such as hydrogen and carbon monoxide atmosphere.
Detailed Parameter
Application of thermocouple wire:
1. Heating - Gas burners for ovens
2. Cooling - Freezers
3. Engine protection - Temperatures and surface temperatures
4. High temperature control - Iron casting

Thermocouple wire allows temperatures to be measured electronically. A typical thermocouple construction consists of a pair of dissimilar metals that are electrically joined together at the sensing point and connected to a voltage measuring instrument at the other end. When one junction is hotter than the other, a thermal "electromotive" force (in millivolts) is produced that is roughly proportional to the difference in temperature between the hot and cold junctions.
NiCr-NickelSi (Type K) thermocouple wire finds the widest use in all basemetal thermocouple, at temperature above 500 °C.
Type K thermocouple wire has strong resistance to oxidation than other base metal thermocouples. It has high EMF against Platinum 67, excellent temperature accuracy, sensitivity and stability, with a low cost. It is recommended for oxidizing or inert atmospheres, but cannot be used directly in the following cases:
(1) Alternatively oxidizing and reducing atmosphere.
(2) Atmosphere with sulphur gases.
(3) Long time in vacuum.
(4) Low oxidizing atmosphere such as hydrogen and carbon monoxide atmosphere.
Detailed Parameter
Chemical Composition for thermocouple wire | |||||
Conductor Name | Polarity | Code | Nominal Chemical Composition /% | ||
Ni | Cr | Si | |||
Ni-Cr | Positive | KP | 90 | 10 | -- |
Ni- Si | Negative | KN | 97 | -- | 3 |
Working Temperature of thermocouple wire | ||
Diameter/mm | Long time Working temperature /ºC | Short period Working temperature /ºC |
0.3 | 700 | 800 |
0.5 | 800 | 900 |
0.8,1.0 | 900 | 1000 |
1.2,1.6 | 1000 | 1100 |
2.0,2.5 | 1100 | 1200 |
3.2 | 1200 | 1300 |
Application of thermocouple wire:
1. Heating - Gas burners for ovens
2. Cooling - Freezers
3. Engine protection - Temperatures and surface temperatures
4. High temperature control - Iron casting