Landworld Bidirectional High Power 6.6kw Obc on-Board Power Supply for Electric Passsenger Car图1Landworld Bidirectional High Power 6.6kw Obc on-Board Power Supply for Electric Passsenger Car图2Landworld Bidirectional High Power 6.6kw Obc on-Board Power Supply for Electric Passsenger Car图3Landworld Bidirectional High Power 6.6kw Obc on-Board Power Supply for Electric Passsenger Car图4Landworld Bidirectional High Power 6.6kw Obc on-Board Power Supply for Electric Passsenger Car图5Landworld Bidirectional High Power 6.6kw Obc on-Board Power Supply for Electric Passsenger Car图6

Landworld Bidirectional High Power 6.6kw Obc on-Board Power Supply for Electric Passsenger Car

Price $2500.00
Min Order 5 Pieces  
Shipping from Guangdong, China
Quantity
-+
Product details
LWC6K6B-220S380-W
No
ISO
EV Onboard Charger
LANDWORLD
364x224x100mm
China
Product Description

Product Features:
  1. Product dimension: 364x224x100mm
  2. Product weight: ≤8.5KG
  3. Cooling method: liquid cooled, flow≥6L/min
  4. IP rating: IP67
  5. Support on-line upgrade and fault diagnosis
  6. High power density, modular design, easy for modular integration
  7. Full digital SW design, redundant protection function design
  8. Multi 6.6KW OBC can be paralleled; (2*6.6Kw , 3*6.6KW, 4*6.6KW OBC)


Main Technical Parameters
 
ItemsTechnical SpecificationRemarks
OBC Electrical Features
Nominal output power6.6KW 
Input Voltage85-265VAC 
Input current32A Max 
Power factor≥0.99(220Vac @ full load) 
Output voltage range250-450VDCCan be adjusted according to battery voltage
Max output current20A 
Efficiency≥94%Nominal voltage
Voltage accuracy±1% 
Current accuracy±1% 
Inverter features
Input voltage range250-450VDC 
Output voltage220Vac(±5%)/50Hz 
Power6.6kVA 
Efficiency≥94% 
Output harmonics(THDv)<3%(Linear load) 
Dynamic response60ms(Linear load) 
Leakage current protection threshold≤30mA 
Other Electrical Features
Operating temp.-40-85ºCCoolant inlet temperature
Low voltage wake-up12Vdc&200mAmax(WAKE_UP signal)Wake up BMS/VCU
Wake-up modeCAN,AC,CC/CPSupport reserve charging
CAN communicationCAN-BUS 
Static current≤1mASleep mode/ consume battery current at stop status
ProtectionInput OVP, UVP, output OVP, UVP, OTP, OCP, output short circuit protection, communication fault protection
EMCGB/T18387-2008,EN 55022