• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
LED Backup Light, LED Emergency Recessed Downlight图1LED Backup Light, LED Emergency Recessed Downlight图2LED Backup Light, LED Emergency Recessed Downlight图3LED Backup Light, LED Emergency Recessed Downlight图4LED Backup Light, LED Emergency Recessed Downlight图5LED Backup Light, LED Emergency Recessed Downlight图6

LED Backup Light, LED Emergency Recessed Downlight

Price $12.00
Min Order 500 Pieces  
Shipping from Zhejiang, China
Quantity
-+
Product details
LEK02-3NC
Emergency Light
3-4h
Recessed
Cool White
IP20
Non-maintained
Ni-Cd Battery
Cool White
Plastic
CE, RoHS, CB
4 Years
150lm
90-95%
24 Hours
flolite
Color Box
40mm Cutout hole
China
8504401400
Product Description
CB Approved 3W LED Emergency light with Ni-Cd batteries 3Hours Backup 



Relevant Standard

EN 60598-1

EN 61000-3-2

IEC 60598-1

IEC61000-3-2

EN 60598-2-22

EN 61000-3-3

IEC 60598-2-22

IEC 61000-3-3

EN 61347-1

EN 62471

IEC 61347-1

IEC 62471

EN 61347-2-13

EN 62493

IEC 61347-2-13

IEC 62493

EN 61347-2-7

EN 55015

IEC 61347-2-7

IEC 55015

EN 62778

EN62031

IEC 62778

IEC62031

 

Product Parameter

Model No.:

LEK02-3NC

Battery:

Ni-Cd, 3.6V 2000mAh

LED Chips:

CREE XT-E

Luminous Flux:

150lm

Power Consumption:

3W

Input Voltage:

AC220-240V~50/60Hz

Charge time:

24Hours

Emergency duration:

3Hours

ta:

0~35ºC

Max. Case Temp.:

70ºC

Protection Class:

II

IP Rating:

IP20

Operation:

Non-maintained

Function:

AUTO test

 

Dimension



Installation Diagram

                                   Wire preparation:

                                  0.5~1.5mm²



AUTO Test

∷ Commissioning test-

Connection of the mains supply will initiate commissioning where the battery will remain on charge for an uninterrupted 24 hours; An interruption of the mains supply will reset the counter to zero.

After 24hours, the luminaire will be put into a duration test for the rated period, immediately followed by another 24hr charge period.

 

∷ Function test-

A 5 second functional test is carried out at 1 week interval.

 

∷ Duration test-

A full rated duration test is carried out at 13 weeks intervals.

System status is indicated by a bi-color LED.

 

LED indication

Status

Commentary

Permanent green

Everything works correctly

 

One flashed 4 seconds pause

Battery failure

Battery is not connected

Two flashed 4 seconds pause

Battery failure

Battery short or low battery   Voltage

Three flashed 4 seconds pause

Load failure

LED failure

Green and Red off

DC mode

Battery operation (Emergency   mode)

 

Special Notes

∷ This product should be installed by a registered electrician in accordance with local standards and electrical regulations;

Take care to ensure the mains supply is isolated before installation;

The light source of this luminaire is not replaceable; when the light source reaches its end of life, the whole luminaire shall be replaced;

The whole luminaire should be replaced when they no longer meet their rated duration of operation after the corresponding recharge period.