1. GENERATOR DATA
Voltage Available:
50Hz: 380-400-415V/220-230-240V;
60Hz: 220-380-416-440-480V/110-208-220-240V
Any special voltage is also available as client's request
Prime Power:
Comply with GB/T2820-97(eqv.ISO8528).
Genset can run unlimitedly under certain power range.
One hour 10% over load in every 12 running hours is allowed;
Standby Power:
standby power is the limit value of maximum output for emergency use.
It is off-oil power,overloading is prohibited
2. MAIN SPECIFICATION
| Axial Gas Turbine Specifications: | |
| Compressor | |
| Type: | Axial |
| Number of Stages: | 14 |
| Compression Ratio: | 17.2:1 |
| Combustion Chamber | |
| Type: | Annular; SoLoNOx |
| Ignition: | Torch |
| Number of Fuel Injectors: | 21 |
| Turbine | |
| Type: | Reaction, Axial Flow |
| Number of Stages: | 3 |
| Gas Turbine Performance and Emissions | |
| The following performance is expected at the given site specifications: | |
| Site Performance Details | |
| KW Gross Output @ ISO Conditions: | 34,040 kW |
| Site Ambient Temperature for Performance Analysis: | 15 °C |
| Site Elevation for Performance Analysis: | 0 metre |
| Site Ambient Relative Humidity for Performance Analysis: | 60% |
| Turbine Inlet Pressure Loss: | 101.6 mmH2O |
| Turbine Outlet Pressure Loss: | 254.0 mmH2O |
| Turbine Fuel Consumption @ specified site conditions (LHV): | 9395.7 Nm3/hr |
| KW Gross Output @ specified site conditions: | 31,917 kW |
| Gas Compressor Power Consumption: | 540 kW |
| Turbine Auxiliary Power Consumption: | 102 kW |
| Total Auxiliary Power Consumption: | 854 kW |
| Net Turbine Power Production: | 31,063 kW |
| Boilers: Condensate | |
| Return: Condensate | 90% |
| Temperature: Makeup | 100 °C |
| Water Temperature: Process | 21 °C |
| Steam Pressure: | 39.0 Bar |
| Process Steam Temperature: | 450 °C |
| Steam Contributed by Gas Turbines: | 43,943 kg/hr |
| Steam Contributed by Ductburners: | 43,188 kg/hr |
| Ductburner Fuel Consumption (LHV): | 3283.1 Nm3/hr |
| Deaerator Steam Consumption: | 2,134 kg/hr |
| Boiler Steam Flow (HRSG design uses 15.0°C pinch, 10.0°C approach): | 87,134 kg/hr |
| Steam Flow to Process: | 0 kg/hr |
| Steam Turbines: | |
| Steam Flow to Turbines: | 85,000 kg/hr |
| Steam Turbine KW Production: | 16,000 KW |
| Cycle Performance (lower heating value basis): | |
| Net Turbine Electrical Heat Rate: | 6,510 kJ/kWHR |
| Combined Gas Turbine and Steam Turbine Gross KW Production: | 50,040 KW |
| Gross Plant Heat Rate (Process steam or Tons converted to equivalent KW): | 8,830 kJ/kWHR |
| Overall Cycle Efficiency (LHV): | 40.80% |
3. PRODUCT FEATURES
(1).Full control panel with power indicator light and oil light.
(2).Emergency shutdown for low oil pressure and high water temperature.
(3).Large fuel tank ensure continuous running.
(4).Low noise & vibration.
(5).Compact structure.
(6).Reliable performance.
(7).Easy for installation and maintenance.
(8).50Hz and 60Hz both are available for choice