Inscinstech Laboratory Instrument Pilot Scale Fplc Chromatography System Protein Purification System (Unique AutoPure Pilot600)图1Inscinstech Laboratory Instrument Pilot Scale Fplc Chromatography System Protein Purification System (Unique AutoPure Pilot600)图2Inscinstech Laboratory Instrument Pilot Scale Fplc Chromatography System Protein Purification System (Unique AutoPure Pilot600)图3Inscinstech Laboratory Instrument Pilot Scale Fplc Chromatography System Protein Purification System (Unique AutoPure Pilot600)图4Inscinstech Laboratory Instrument Pilot Scale Fplc Chromatography System Protein Purification System (Unique AutoPure Pilot600)图5Inscinstech Laboratory Instrument Pilot Scale Fplc Chromatography System Protein Purification System (Unique AutoPure Pilot600)图6

Inscinstech Laboratory Instrument Pilot Scale Fplc Chromatography System Protein Purification System (Unique AutoPure Pilot600)

Price $0.00
Min Order 1 Piece  
Shipping from Jiangsu, China
Quantity
-+
Product details
Unique AutoPure pilot600
1 Year
1 Year
Biochemistry
CE, ISO
Liquid
Liquid Chromatography
Preparative Column
Unique Cdsystem
4-600ml/Min
60kg
Inscinstech
Flight Case
600X500X850mm
Product Description

System performance parameters AutoPure Pilot600 m performance parameter

Main system size L*W*H 600x500x850mm
Main system weight 65kg
Control system Unique CDSystem
Enclosure rating IP54
Electricity supply 100~ 240 V, 50 ~ 60 Hz
Working environment Temperature: 4ºC~35ºC,
Relative Humidity: 20%~95%, no condensation
System pump
(Dual pump system)
A/B pump
Flow rate range: 4~600ml/min
(2- pump packing mode: 1~ 1200ml/min)
Eligibility range: 5%~95%
Pressure range: 0~ 2MPa (20bar, 290 psi)
Viscosity: 0.7~10 cp











UV detector
280nm fixed wavelength detector
LED light source, lifespan>8000h
Detection range: - 6~ +6AU
Linearity: between±2%@0 ~ 2AU
Wavelength Accuracy: ±1nm
Wavelength Repeatability: ±0.1nm
Noise:±2*10 - 5AU
DAD full spectrum direct
reading detector,
200~400nm variable dual wavelength.
Wavelength Accuracy: ±1nm
Wavelength Repeatability: ±1 nm
Noise: ±4*10 - 5AU
(@254nm,1S)

 
Optical fiber conduction, external flow cell, avoid light source temperature
affecting the activity of protein samples, double beam design with high
stability.
Standard flow cell: 2mm optical diameter, 50μl flow cell volume,
maximum pressure resistance 2Mpa
Conductivity detectorDetection range: 0.1mS/cm ~ 999.9mS/cm
Detection cell volume: 20μl
Accuracy: ±3% or 0.2mS/cm
built-in temperature sensor, automatic compensation calibration
Temperature detectorTemperature range: 0 ~99ºC;
Temperature Accuracy:± 2ºC 2ºC ~50ºC
pH detectorDetection range:2~ 12;Accuracy: ±0.15
Inlet options 4 inlets for single pump
A total of 8 inlets of double pumps
Expandable to 12 inlets
Outlets options Maximum 8 outlets
Column valve Single column
Bubble trapEffectively remove air bubbles in flowpath, optional online or offline
MixerMixing chamber volume: 12ml
Bubble sensorSupport up to 3
Pressure sensorOne after each pump(A,B), one before the column, one after the column,
a total of four, detection range is 0- 2MPa