Unlock the full potential of your power distribution system with MOREDAY's Oil Immersed Power Distribution Transformers. Designed for high performance and reliability, our transformers ensure seamless power delivery and superior efficiency for various industrial and commercial applications.
Key Features:
- High Efficiency: Our oil immersed transformers are engineered to minimize energy losses, providing exceptional efficiency and reducing operational costs.
- Enhanced Cooling: Utilizing mineral oil or synthetic oils, these transformers offer excellent cooling properties, ensuring optimal operating temperatures and prolonged lifespan.
- Robust Construction: Built with high-quality materials and advanced manufacturing techniques, MOREDAY transformers guarantee durability and long-term performance in demanding environments.
- Superior Insulation: Equipped with high-grade insulation materials, our transformers deliver excellent electrical and mechanical strength, enhancing safety and reliability.
- Low Noise Operation: Designed to operate quietly, our transformers are suitable for installation in noise-sensitive areas, ensuring a peaceful working environment.
- Safety and Compliance: Adhering to international safety standards, MOREDAY transformers incorporate advanced protection mechanisms to safeguard against electrical faults and hazards.
Technical Parameter for S11 Series 6kv-llkvNo-load Voltage Regulation Trans formers | ||||||||||||
Rated Capacit Y(KVA | Voltage Combination | Connection Group Symbol | No- load Loss (W) | Toad Loss (W) | Impedance Voltage(%) | No-load Current (%) | L*W*H(mm | Gauge Horizonta 1*Vertica (mm) | Active parts Weight (kg *Oil Weight (kg) | Tota Weigh (kg) | ||
High Voltag e (KV | Tapping Range of High Voltage | Low Voltag e (KV) | ||||||||||
30 | 6 6.3 10 10.5 11 | ±5% ±2x2.5% | 0.4 | Dyn11 Yzn11 Yyn0 | 100 | 630/600 | 4 | 2.8 | 980*735*1145 | 400*400 | 178*78 | 355 |
50 | 130 | 910/870 | 2.5 | 1017*758*1205 | 450*400 | 240*92 | 415 | |||||
63 | 150 | 1090/1040 | 2.4 | 1035*785*1285 | 450*400 | 285*105 | 505 | |||||
80 | 180 | 1310/1250 | 2.2 | 1065*800*1290 | 450*400 | 330*110 | 540 | |||||
100 | 200 | 1580/1500 | 2.1 | 1072*820*1305 | 450*400 | 345*116 | 590 | |||||
125 | 240 | 1890/1800 | 2 | 1155*1105*131 | 450*400 | 415*135 | 705 | |||||
160 | 280 | 2310/2200 | 1.9 | 1235*850*1535 | 550*550 | 485*135 | 835 | |||||
200 | 340 | 2730/2600 | 1.8 | 1282*860*1557 | 550*550 | 582*168 | 965 | |||||
250 | 400 | 3200/3050 | 1.7 | 1310*940*1605 | 550*550 | 695*210 | 1135 | |||||
315 | 480 | 3830/3650 | 1.6 | 1465*1120*191 | 660*650 | 855*255 | 1520 | |||||
400 | 570 | 4520/4300 | 1.5 | 1440*1165*172 | 660*650 | 950*295 | 1590 | |||||
500 | 680 | 5410/5150 | 1.4 | 1510*1250*184 | 660*650 | 1150*320 | 1905 | |||||
630 | 810 | 6200 | 4.5 | 1.3 | 1650*1140*192 | 660*650 | 1500*435 | 2015 | ||||
800 | 980 | 7500 | 1.2 | 2125*1175*231 | 820*820 | 1910*760 | 3510 | |||||
1000 | 1150 | 10300 | 1.1 | 2150*1380*257 | 820*820 | 2125*880 | 3850 | |||||
1250 | 1360 | 12000 | 1 | 2355*1485*257 | 820*820 | 2605*960 | 4610 | |||||
1600 | 1640 | 14500 | 0.9 | 2335*1750*263 | 820*820 | 3125*1150 | 5420 | |||||
2000 | 1940 | 18300 | 5 | 0.4 | 1940*1400*170 | 820*820 | 2420*780 | 4200 | ||||
2500 | 2290 | 21200 | 0.4 | 2050*1480*180 | 820*820 | 2560*780 | 4680 |
1. What is an oil immersed transformer?
An oil immersed transformer uses oil for cooling and insulation. The oil circulates within the transformer, dissipating heat and maintaining optimal operating temperatures.
2. What are the benefits of using MOREDAY oil immersed transformers?
MOREDAY oil immersed transformers offer high efficiency, excellent cooling, robust construction, superior insulation, low noise operation, and adherence to international safety standards, ensuring reliable and durable performance.
3. Where can MOREDAY oil immersed transformers be used?
Our oil immersed transformers are ideal for industrial facilities, commercial buildings, renewable energy projects, and utility networks, providing reliable power distribution in a variety of settings.
4. How do I choose the right oil immersed transformer for my needs?
Selecting the right transformer depends on factors such as power capacity, voltage levels, and specific application requirements. Our sales team can assist you in choosing the best solution tailored to your needs.
5. What maintenance is required for oil immersed transformers?
Regular maintenance includes checking oil levels, inspecting for leaks, performing oil tests, and cleaning cooling components. These steps help ensure the transformer operates efficiently and has a long lifespan.
6. Are MOREDAY oil immersed transformers energy efficient?
Yes, MOREDAY oil immersed transformers are designed to minimize energy losses, providing high efficiency and reducing operational costs.
7. What safety features are included in MOREDAY oil immersed transformers?
Our transformers are built with high-grade insulation materials, robust construction, and advanced protection mechanisms to prevent electrical faults and hazards, ensuring safe operation.
8. Do MOREDAY oil immersed transformers come with a warranty?
Yes, our transformers come with a comprehensive warranty to ensure peace of mind and reliable performance. Please contact our sales team for specific warranty details.
9. How can I get a quote for a MOREDAY oil immersed transformer?
You can request a quote by visiting our website or contacting our sales team directly. Provide your specific requirements, and we will offer a tailored solution to meet your needs.
10. What certifications do MOREDAY oil immersed transformers have?
Our transformers are certified to meet international standards, including TUV, CE, and CB certifications, ensuring top-quality performance and safety.