Hospital First Aid Portable Biphasic External Aed Defibrillator with Monitor图1Hospital First Aid Portable Biphasic External Aed Defibrillator with Monitor图2Hospital First Aid Portable Biphasic External Aed Defibrillator with Monitor图3Hospital First Aid Portable Biphasic External Aed Defibrillator with Monitor图4Hospital First Aid Portable Biphasic External Aed Defibrillator with Monitor图5Hospital First Aid Portable Biphasic External Aed Defibrillator with Monitor图6

Hospital First Aid Portable Biphasic External Aed Defibrillator with Monitor

Price $2800.00
Min Order 1 Piece  
Shipping from Jiangsu, China
Quantity
-+
Product details
DM7000
Defibrillator
ICU,Nicu First Aid,Ambulance, Hospital Use
CE, ISO13485
Adult
Without LCD Display
4-16 Sec
25mm/Sec
7 Inch High Resolution LCD Display
4sec. To150j 8 Sec. to 200 J
Unit Operates on Internal Battery Only
Automatic External Defibrillator
Rechargeable, Ni-MH Battery, 12V
Poweam
1 PCS/Carton
ISO. CE
Nanjing
90181930
Product Description
AED biophasic defibrillator with monitor function can meet all of your clinical request from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS).

Technical Specifications

Display
Display Type: 7 inch high resolution LCD display
Sweep Speed: 25mm/sec
Information: HR, Lead/Pads, On/Off Alarm , SpO2, AED Functions and Prompts, Alarm Selection
and Limits, Delivered Energy.

Below is feature:
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.

ECG Monitoring
Patient Connection: 5-lead ECG cable, or 3-lead ECG cable, paddles.
Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor, user-selectable.
Smart Alarms: Beeper/voice prompts indicate shockable rhythm.


SpO2 Module
Measurement Range: 30~100%, ± 2% between 80%~90%, others ± 5%
Alarm Accuracy: ± 10% within setting values.
Alarm Range: User set high limit and low limit.
Alarm time Accuracy: Less than 12 sec.

Recorder
Paper: 50mm thermal.
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution, thermal print head.
Print-out Modes: Manual or automatic, user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.

Battary
Type: Rechargeable, Ni-MH battery, 12V.
Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.

AED Mode
AED Function: Auto analyze and charge X3 with programmable auto energy level selection, screen prompts, and voice prompts.
Shockable Rhythms: Ventricular fibrillation with amplitude >=200UV, ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms.
Charge Control: Control on device front panel, press key on paddle.
Prompts: Voice and visual prompts.

Manual Mode
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.
Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor
 
ModelDM7000
Brief Introductionbiophasic AED defibrillator,7" LCD
Patient Monitor
ECG,HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts,
Alarm Selection and Limits, Delivered Energy.