• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
High Voltage Current Limiting Porcelain/Ceramics Fuse Cutout, Drop out Fuse with Cutout Holder 15kv 100A图1High Voltage Current Limiting Porcelain/Ceramics Fuse Cutout, Drop out Fuse with Cutout Holder 15kv 100A图2High Voltage Current Limiting Porcelain/Ceramics Fuse Cutout, Drop out Fuse with Cutout Holder 15kv 100A图3High Voltage Current Limiting Porcelain/Ceramics Fuse Cutout, Drop out Fuse with Cutout Holder 15kv 100A图4High Voltage Current Limiting Porcelain/Ceramics Fuse Cutout, Drop out Fuse with Cutout Holder 15kv 100A图5High Voltage Current Limiting Porcelain/Ceramics Fuse Cutout, Drop out Fuse with Cutout Holder 15kv 100A图6

High Voltage Current Limiting Porcelain/Ceramics Fuse Cutout, Drop out Fuse with Cutout Holder 15kv 100A

Price $22.00
Min Order 2 Pieces  
Shipping from Zhejiang, China
Quantity
-+
Product details
DG1
High
Expulsion Drop-out
High Voltage
FF
Fuse Holder
IEC/ANSI/IEEE
10-38kv
100/200/300
8,000/10,000
250-700
DGG
Export Carton
China
Product Description
Our factory

We are professional manufacturer of current transformer ,voltage transformer, Vacuum Circuit Breakers/Recloser,Isolation switches,Dropout Fuse Cut-out,Lightning Arresters,High and Low Voltage Cabinets,Metering Devices,Power Distribution Transformers  etc.
We are a 25 years professional manufacturer in fuse cutout. And we are a qualified supplier for the Chinese government.

Application

The primary purpose of any cutout is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks.Our cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupt capacity.

In addition, this type of cutouts can also be used as a sectionalizing device. With the use of a portable load break tool, type C cutouts can function much like an overhead disconnect switch. A 300amp disconnect blade is also available for this purpose.

Interruption tests have been performed at full system line-to-line voltage. In each voltage class, there are continuous current ratings of 100 amps,200 amps, and 300 amps.



Technical Reference (All details can be customized)
 
TypeRated Voltage (kV)Rated Current (A)Breaking Current (A)Impulse Voltage (BIL)Power frequency withstand voltage (kV)Creepage distance (mm)Weight (kg)Dimension (cm)
DG1-1210-15100/200/3008,000/10,00011040250641*36*10
DG1-1515-24100/200/3008,000/10,00012545330750*36*11
DG1-2424-27100/200/3008,000/10,00015065540950*39*14
DG1-3030-38100/200/3008,000/10,000170707001159*36*14

Our Customer

Our customers are located all over the world.

Test Reports
We have test reports for drop type fuse products that have been validated by KEMA Laboratory:Photos of Product