• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
High Quality 12V 28ah Gel Lead Acid Battery图1High Quality 12V 28ah Gel Lead Acid Battery图2High Quality 12V 28ah Gel Lead Acid Battery图3High Quality 12V 28ah Gel Lead Acid Battery图4High Quality 12V 28ah Gel Lead Acid Battery图5High Quality 12V 28ah Gel Lead Acid Battery图6

High Quality 12V 28ah Gel Lead Acid Battery

Price $35.00
Min Order 100 Pieces  
Shipping from Guangdong, China
Quantity
-+
Product details
MLG12-28
Lead-Acid Batteries
UPS, Electric Power, Lighting, Boat
12V
Low Discharge Rate
Square Battery
Acid
Fixed
Chargeable
28ah
8.6kg
T5 or F7
Sealed
Initinal Charging Current Less Than 60A
13.5~13.8V
Stored for up to 6 Months
Sunstone Power
Factory Carton+Pallet
175*166*125mm
China
85072000
Product Description

Introduction for MLG series
Sunstone MLG series battery is designed specially to meet requirement of frequent cyclic and high temperature application such as board had, PVs etc. We use high quality separator and silica from Europe. And we use special technology to fill acid firstly then after about 20 hours charge and discharge, fill out all acid then fill in silica separately to make sure each cell can get enough silica and complete penetration of electrolyte through separators and plates pastes from top to bottom.

 
Product Description
Nominal  Voltage12V  (6 cells)Operating Temp.RangeDischarge:  -15-50°C (5-122°F)
Nominal  Capacity29.2AH (20hr, 1.80V/cell, 25°C/77°F)Charge:0-40°C (32-104°F)
28AH (10hr, 1.80V/cell, 25°C/77°F)Storage: -15-40°C (5-104°F)
26.2AH (5hr, 1.75V/cell, 25°C/77Nominal Operating Temp.Range25 ± 3°C ( 77 ± 5°F)
16.8AH (1hr, 1.60V/cell, 25°C/77°F)Cycle Use14.4~14.8V (25°C/77°F)  Temp.Coefficient -30mV/°C
DimensionLength                                 175± 2mmInitial Charging Current Less than 8.4A
Width                                  166± 2mmStandby Use13.5~13.8V (25°C/77°F)  Temp.Coefficient -20mV/°C
Container Height                   125 ± 2mmNo limit on Initial Charging Current 
Total Height(with Terminal)    125 ± 2mmCapacity affected by
Temperature
40°C (104°F)             103%
Approx WeightApprox 8.6Kg25°C (77°F)               100%
TerminalT1 or F30°C (32°F)                 86%
Container MaterialABSSelf DischargeMLG series batteries may be stored for up to 6 months max
Max. Discharge Current350A (5S)At 25°C (77°F) and then a freshening charge is required.
Internal ResistanceApprox 12mΩFor higher temperatures the time interval will be shorter.
Features
Maintenance-free operation
Compact design
ABS case, Flame Retardant V0 is available
Stable quality and high reliability
10 years design life (at 25°C)
Detailed Photos



 

Application

Company Profile

Sunstone Power Co. was established in 2003 in manufacturing, marketing, and brand name building of lead-acid batteries/battery plates.

Our factories (both plates factory & assembling factory) locate in Kunming City, Yunnan P.R. China. Since Yunnan P.R. is one of the main lead supply

areas, we have good advantages in quality control, delivery control, and cost control. So far we are the only factory that gets pollution control

permission from the government in Yunnan P.R.

Besides this, we set up our German company in Frankfurt in 2017 and an Indonesian company in Jakarta at the end of 2018.

We have our warehouse in both these two countries. It gives fast delivery and stock support to European and Southeast Asian markets.



Partners :

Certifications

Sunstone Power has been ISO9001 ,ISO14001 approved and soon on ,many of our products obtained CE,IEC,VDS,RISTI(BY PT. TELKOM INDONESIA) certificates .
FAQ

Payment
1. Pay through T/T, western union, PayPal…
2. Price term: FOB Shenzhen port, CFR, CIF.
3. The customer is responsible for any tax or bank charges by their countries.

Packaging & Shipping
1. By sea, by air shipping, by car or train, other good shipping ways also welcomed.
2. We will send products in 30- 35 days after the bank receipt.
3. A tracking number and photos of products will send by email after arrange shipped.

Notice
1. Don't near the hot source and don't under the sunshine.
2. Don't charge in the sealed container.
3. No short circuit. It should be the additional charge if you don't use, and a single charge per three months, to avoid
irreversible sulfating. The battery should be changed when the battery jar is broken or the electrolyte omitted, to avoid acid
corrosion.
4. Don't store in the space of acid gas.
5. You should be careful and regular check when using the battery. To avoid the battery don't work. You should change the battery
if the capacity is not full or has been damaged, especially after one year using.
6. Don't put the battery in the fire, or it will explode.
7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the
electrolyte.
8. Don't clean the battery by using the organic solution. (e.g. petrol) 

Buyer review
Loading review details...
Contact

Shenzhen Sunstone Power Technology Co., Ltd

Audited Supplier2 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

Recommended for you