HVHIPOT high voltage test equipment manufacturers 300kV/30kJ Impulse Voltage Test图1HVHIPOT high voltage test equipment manufacturers 300kV/30kJ Impulse Voltage Test图2HVHIPOT high voltage test equipment manufacturers 300kV/30kJ Impulse Voltage Test图3HVHIPOT high voltage test equipment manufacturers 300kV/30kJ Impulse Voltage Test图4HVHIPOT high voltage test equipment manufacturers 300kV/30kJ Impulse Voltage Test图5HVHIPOT high voltage test equipment manufacturers 300kV/30kJ Impulse Voltage Test图6

HVHIPOT high voltage test equipment manufacturers 300kV/30kJ Impulse Voltage Test

Price $49300.00
Min Order 1 Set  
Shipping from Hubei, China
Quantity
-+
Product details
GDCY-300kV/30kJ
yes
1 year
Impulse Voltage Test
300kV
0.666µF
30kJ(5kJ/stage)
±100kV
3
2µF
HVHIPOT
Wooden Case
SGS, ISO
Wuhan, China
9030339000
Product Description
General Information

This impulse test system is used for carrying out full wave lightning impulse voltage tests on HV apparatus such as clearance, bushings, capacitors, switches, power transformers (capacity below 5000kVA), CT/PT at 35kV or below.


Specifications
 
  1. Nominal voltage: ±300kV
  2. Rated energy: 30kJ(5kJ/stage)
  3. Impulse capacitance: 0.666µF
  4. Number of Stage: 3
  5. Charging voltage per stage: ±100kV
  6. Rated level capacitance: 2µF (each impulse capacitor 2µF at 100kV, total 3pcs)
  7. Output voltage waveform: (Load capacitance is 300-3000pF) T1= 1.2µs±30%, T2=50µs±20%, peak voltage error≤3% standard lightning impulse voltage full wave.
  8. Impulse voltage waveform parameters and error are accorded with national requirements of GB311.1and GB16927.1 standard and IEC standard.
  9. Output Voltage Efficiency: Standard lightning wave ≥90% when load capacitance is below 1000pF, standard lightning wave ≥85% when load capacitance is below 2000pF.
  10. Locking range: level voltage is within the range of 20%-100% of rated voltage, positive and negative locking range no less than 25%.
  11. Out-of-control rate of synchronous discharge: <5%
  12. Min. output voltage: ≥±10% of rated voltage.
  13. Instability of charging voltage: <±1.0%
  14. Continuous time: Above 2/3 of rated voltage, continuous working when charge anddischarge once every 120s. Below 2/3 of rated voltage, continuous working when charge and discharge once every 60s.