G630
                        Industrial Machine Motors
                        Triple
                        Vector Control Transducer
                        PWM Control
                        Voltage
                        Low Voltage Variable-Frequency Drive
                        AC-DC-AC Variable-Frequency Drive
                        Voltage Variable-Frequency Drive
                        Elevator Special, Textile Special, Constant Torque Universal Type
                        Vekont
                        (Heavy/Normal -Duty) Models
                        Digital Dual Display Keypads
                        1:200 (Open-Loop Vector Control)
                        G-Model: 0.5Hz/180% (Open-Loop Vector Control)
                        Less Than 40ms (Open Loop Vector Control)
                        Open-Loop Vector Control (SVC), V/F Control
                        0.00Hz~50.00Hz
                        0.0s~3000.0s
                        0.0~36.0 Seconds
                        IEC 61800-3:2005
                        IEC 61800-5-1:2007
                        Less Than 5.9 M/S2 (0.6 G)
                        0.0%~100.0%
                        Less Than 95% Rh, No Water Droplet Condensation
                        Below 1000 Meters, Above 1000 Meters
                        Vekont
                        Standard Export Packing
                        Based on different power
                        Hunan
                        8504409999
                        
                        Product Description
                    
                                
                                    G630 CE Approved 220V 380V 440V 480V 10hp 20hp 50hz 60hz Frequency Inverter
 
1.Product Advantage:
High performance
Easy operation
Compact Structure
GP (heavy/normal -duty) models
Digital dual display keypads
Widely used in industrial application
Suitable for permanent magnet synchronous motors
2.Capacity range:
Single phase 220V(2S): 0.4kw-5.5kw
Three phase 220V(2T): 0.4kw-220kw
Three phase 380V(4T): 0.75kw-1000kw
3.International standards:
IEC/EN 61800-5-1:2007
IEC/EN 61800-3: 2004
4.Example of connecting to a peripheral machine:

5.Naming Rule:

6.Nameplate:

7.Models and Technical Data
8.Technical specification:
 
9.Wiring method:

10.Product Show:




                    
                1.Product Advantage:
High performance
Easy operation
Compact Structure
GP (heavy/normal -duty) models
Digital dual display keypads
Widely used in industrial application
Suitable for permanent magnet synchronous motors
2.Capacity range:
Single phase 220V(2S): 0.4kw-5.5kw
Three phase 220V(2T): 0.4kw-220kw
Three phase 380V(4T): 0.75kw-1000kw
3.International standards:
IEC/EN 61800-5-1:2007
IEC/EN 61800-3: 2004
4.Example of connecting to a peripheral machine:

5.Naming Rule:

6.Nameplate:

7.Models and Technical Data
| Inverter Model | Input Voltage | Input Current (A) | Output Current (A) | Adapted motor (kW) | 
| G630/G630S-3SR4G | Single-phase 220V Scope: -15%~20% | 5.4 | 2.3 | 0.4 | 
| G630/G630S-3SR75G | 8.2 | 4.0 | 0.75 | |
| G630/G630S-3S1R5G | 14.0 | 7.0 | 1.5 | |
| G630/G630S-3S2R2G | 23.0 | 9.6 | 2.2 | |
| G630/G630S-4TR75GB | Three-phase 380V Scope: -20% to 20% | 3.4 | 2.1 | 0.75 | 
| G630/G630S-4T1R5GB/2R2PB | 5.0/5.8 | 3.8/5.5 | 1.5/2.2 | |
| G630/G630S-4T2R2GB/4R0PB | 5.8/10.5 | 5.5/9.0 | 2.2/4.0 | |
| G630/G630S-4T4R0GB/5R5PB | 10.5/14.6 | 9.0/13.0 | 4.0/5.5 | |
| G630/G630S-4T5R5GB/7R5PB | 14.6/20.5 | 13.0/17.0 | 5.5/7.5 | |
| G630/G630S-4T7R5GB/011PB | 20.5/26.0 | 17.0/25.0 | 7.5/11.0 | |
| G630/G630S-4T011GB/015PB | 26.0/35.0 | 25.0/32.0 | 11.0/15.0 | |
| G630/G630S-4T015GB/018PB | 35.0/38.5 | 32.0/37.0 | 15.0/18.5 | |
| G630/G630S/-4T018GB/022PB | 38.5/46.5 | 37.0/45.0 | 18.5/22.0 | |
| G630/G630S-4T022GB/030PB | 46.5/62.0 | 45.0/60.0 | 22.0/30.0 | |
| G630/G630S-4T030G(B)/037P(B) | 62.0/76.0 | 60.0/75.0 | 30.0/37.0 | |
| G630/G630S-4T037G(B)/045P(B) | 76.0/92.0 | 75.0/90.0 | 37.0/45.0 | |
| G630/G630S-4T045G(B)/055P(B) | 92.0/113.0 | 90.0/110.0 | 45.0/55.0 | |
| G630/G630S-4T055G(B)/075P(B) | 113.0/157.0 | 110.0/152.0 | 55.0/75.0 | |
| G630/G630S-4T075G(B)/093P(B) | 157.0/180.0 | 152.0/176.0 | 75.0/93.0 | |
| G630/G630S-4T093G(B)/110P(B) | 180.0/214.0 | 176.0/210.0 | 93.0/110.0 | |
| G630/G630S-4T110G/132P | 214.0/256.0 | 210.0/253.0 | 110.0/132.0 | 
8.Technical specification:
| Event | Specifications | |
| P r i m a r y C o n t r o l | Maximum frequency | Vector control: 0~600Hz VF control: 0~1200Hz | 
| Carrier frequency | 1k~15kHz: The carrier frequency can be adjusted automatically according to the load characteristics. | |
| Input frequency resolution | Digital setting: 0.01Hz Analog setting: Maximum frequency × 0.1% | |
| Control method | Open-loop vector control (SVC), V/F control | |
| Starting torque | G-model: 0.5Hz/180% (open-loop vector control) P-model: 0.5Hz/120% (open-loop vector control) | |
| Speed range | 1:200 (open-loop vector control) | |
| Speed stabilization accuracy (Speed control accuracy) | Open-loop vector control: ≤±0.5% (rated synchronous speed) | |
| Speed control stability | Open-loop vector control: ≤±0.3% (rated synchronous speed) | |
| Torque response | ≤40ms (open loop vector control) | |
| Overload capacity | Model G: 150% of rated current for 60 seconds; 180% of rated current for 5 seconds Model P: 120% of rated current for 60 seconds; 150% of rated current for 5 seconds | |
| Torque Increase | Torque increase automatically Torque increase 0.1% to 30.0% manually | |
| V/F curve | Three types: linear; multi-point; squared V/F curve | |
| Acceleration/Deceleration curves | Linear or S-curve acceleration and deceleration mode; Four kinds of acceleration and deceleration time; Acceleration and deceleration time range 0.0s~3000.0s | |
| DC Brake | DC braking frequency: 0.0Hz~maximum frequency Braking time: 0.0~36.0 seconds Braking action current value: 0.0%~100.0% | |
| Jog control | Point-to-point frequency range: 0.00Hz~50.00Hz; Jog acceleration and deceleration time 0.0s~3000.0s | |
| Simple PLC Multispeed operation | Up to 16 speeds via built-in PLC or control terminals | |
| Built-in PID | Process control closed-loop control system can be realized easily | |
| Automatic Voltage Regulation (AVR) | Keep the output voltage constant when the grid voltage changes automatically | |
| Torque limiting and control | "Digger" feature: torque limiting during operation to prevent frequent overcurrent trips automatically; Closed-loop vector mode for torque control | |
| C u s t o m i z e d | Power-up peripherals safety self-test | Power-on safety detection of peripheral devices such as grounding, short-circuiting, etc. can be realized | 
| Common DC bus function | Realize the function of DC bus shared by multiple inverters | |
| JOG key | Programmable key: Forward and reverse operation/spot operation function selection | |
| Textile swing control | Various triangle wave frequency control functions | |
| Fast current limit function | Built-in fast current limiting algorithm Reduces the probability of overcurrent reported Improves the anti-interference ability | |
| Timing control | Function: Setting time range 0h~65535h | |
| Standardization of keyboard extension cables | Customers may extend the keyboard by using a standard network cable | |
| Run | Run command channel | Three types of channels: operator panel given, control terminal given, and serial communication port given. Switchable in various ways | 
| Frequency source | 10 types of frequency sources: digital, analog voltage, analog current, pulse, and serial port give and take. Switchable in various ways | |
| Auxiliary frequency sources | 10 kinds of auxiliary frequency sources. Realization of auxiliary frequency trimming and frequency synthesis flexible. | |
| Input terminal | Standard seven digital input terminals, up to nine digital input terminals (AI1, AI2 can be used as X (DI) terminals), compatible with active PNP or NPN input. Two analog input terminals, of which AI1 can only be used as a voltage input and AI2 can be used as a voltage or current input. | |
| Output terminal | One digital output terminal (bipolar output) Two relay output terminals Two analog output terminals, can be selected from 0/4mA to 20mA or 0/2V to 10V respectively, which can realize the output of physical quantities such as set frequency, output frequency and rotational speed. | |
| Display and keyboard operation | LED display | Display parameters | 
| LCD display | Optional, Chinese/English prompts for operation content | |
| LCD parameter copy | Quick copying of parameters using the LCD | |
| Key lock and function selection | Partial or full locking of keys, defining the scope of action of some keys to prevent misoperation. | |
| Protection and Options | Protective function | Power-on motor short-circuit detection, input and output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, over-heating protection, overload protection, etc. | 
| Optional accessories | LCD operation panel, brake unit, etc. | |
| E N V I R O N M E N T | Location | Indoors, out of direct sunlight, free of dust, corrosive gases, flammable gases, oil mist, water vapor, dripping water or salt, etc. | 
| Altitude | Please use at a reduced rate (below 1000 meters, above 1000 meters) | |
| Environmental temperature | -10ºC~+50ºC (please use at a reduced rating 40ºC~50ºC) | |
| Humidity level | Less than 95% RH, no water droplet condensation | |
| Vibratory | Less than 5.9 m/s2 (0.6 g) | |
| Storage temperature | -20ºC~+60ºC | |
| Contamination level | 2 | |
| Product standard | Product implementation of safety standards | IEC 61800-5-1:2007 | 
| Product implementation of EMC standards | IEC 61800-3:2005 | |

10.Product Show: