FPA, FPAX, FPAR
New-Type Transmitter
AC Transmitter
Single
Two-wire Transmitter
0.2G
ISO
Customized
Haiyan Jinhan Electronic Technology Co., Ltd
1 Piece
Integration
Iron-Shell
75*50*113(Mm)
Screws
About 0.5kg
by Air
Global
Depend on Quantity
Jinhan
Independent Carton Package
SGS
China
9030390000
Product Description
Measuring and conversion IEC 688 / 1992 - 04
Dielectrical strength IEC 688 2KVac / 1 min.
Surge and Impulse test ANSI C37.90 / 1989
IEC 255-3 (1989) 4KV 1.2 x 50 us
FPA 1 unit of avg. to rms conversion
FPAX 3 unit of avg. to rms conversion
FPAR Ture rms conversion


Py : DC24 / 48 / 125 V ± 20% or other range under specified
Note:
External power mode suitably for all output types
Internal power mode, only suitably for 0-1mA / 0-20mA / 0-1V / 0-5V / 0-10V output
Accuracy ( 23±3°C ) 0.2% RO .......... FPA, FPAX, FPV, FPVX
0.2% RO .......... FPAR, FPVR
Maximum output load DC current mode : maximum 10V drop
DC voltage mode : maximum 5mA drive
Dielectric strength AC 2KV 1 minute between terminals; AC 2.6KV 1 minute / terminals to case
Surge and impulse test ANSI C37.90 / 1989, IEC 255-3 (1989) 4 KV 1.2 x 50 us
Maximum input over Current related input Voltage related input
1A / 5A 10A
4 x rated / continuous 2 x rated / continuous 1.5 x rated / continuous
10 x rated / 10 seconds 25 x rated / 1 second 2 x rated / 10 seconds
50 x rated / 1 second 50 x rated / 0.5 second
80 x rated / 0.5 second
Input burden Current less 0.2 VA; voltage less 0.1 VA
Response time & ripple Ø400 ms for step change 0-99% ripple less 0.5% ro peak to peak
Frequency 45 ~ 400 Hz
Stability Temperature range ( 20 to 30°C ) long term stability / year
Maximum 60 ppm / °C less 0.2% draft / year typically
Storage condition Temperature range -25 to 70°C, RH 20 to 95% non condensed
Operating condition Temperature range -20 to 65°C, RH 0 to 99% non condensed
Magnetic field effect < 0.01% under 100 ampere turns at 1M center
Power dissipation Maximum 3.5 VA for FPA / FPAR / FPV / FPVR; 8 VA for FPAX / FPVX
6.Terminal Connection

Model and Ordering
FPA-An-Fn-Pn-On
Example:
1. FPA-A2-F1-P2-03
Input:5A
Auxiliary Frequency:50Hz
Power:AC 220V
Output:4-20mA
If you have any questions about this,welcome to contact us.
We are all at service.

Technical Specification
| Reference Standard | GB/T 13850-1998(IEC688-1992) |
| Accuracy | |
| Long Term stability | ≤±0.2%/year.No accumulation error |
| Temperature influence | ≤ 100ppm/oC |
| Response Time | <400ms |
| Output Ripple | <0.4%(peak-peak value) |
| Input burden | Current less 0.2VA;voltage less 0.1VA |
| Frequency | Nominal frequency ±10% |
| Maximum output load | Current output Max10V pressure drop |
| Auxiliary power | Ratedvoltage80%-120%,rated current 90%-110% |
| Auxiliary load effect | <± 0.1% |
| Allow excessive input | Current 3rate continuous 10rate 30 secs voltageMax 2ratecontinuous |
| Dielectric strength | Input /output /power/between the crust 2KV AC 1 minIEC866 |
| Impact test | ANSIC37.90a/1973,IEC255-4 (5kV1.2/50us PulsedVoltage) |
| Calibration amplitude | Full scale least±3%,zero least±1% |
| Magnetic field effect | 0.4KA/m magnetic field strength change <0.05% |
| Operating condition | Temperature -10~55oC relative humidity≤95%RHnoncondensing |
| Storage condition | Temperature -40~70oC relative humidity ≤95% RHnoncondensing |
Haiyan Jinhan Electronic Technology CO.,LTD
FP Series Electric Quantity Transmitter
| FPA | FPAR | FPAT | FPAX | ||
| FPV | FPVR | FPVT | FPVX | ||
| FPW | FPW201 | FPW301 | FPWT | FPWT201 | |
| FPK | FPK201 | FPK301 | FPKT | FPKT201 | |
| FPWK | FPWK201 | FPWK301 | FPWKA | FPWKA201 | FPWKA301 |
| FPWH | FPWH201 | FPWH301 | FPKH | FPKH201 | FPKH301 |
| FPWWH | FPWWH201 | FPWWH301 | FPKKH | FPKKH201 | FPKKH301 |
| FPF | FPFT | FPPF | FPPFT | FPH | FPS |
| FPD-1 | FPD-2 | FPDH-1 | FPDH-2 | FPT-1 | FPT-2 |
We can provide the product model and specifications:
| Product | Model No. |
| AC current transducer | JD194-BS4I-N |
| AC voltage transducer | JD194-BS4U-N |
| AC current transducer | JD194-BS4I |
| DC current transducer | JD194-BS5I |
| AC voltage transducer | JD194-BS4U |
| DC voltage transducer | JD194-BS5U |
| Power transmitter | JD194-BS4P |
| Power transmitter | JD194-BS4Q |
| Power factor transducer | JD194-BS4H7 |
| Frequency transmitter | JD194-BS4F7 |
| Integrated transmitter | JD194-BS4Z6 |
| Integrated transmitter | JD194-BS4Z8 |
| Integrated transmitter | JD194-BS4Z-S |
| Temperature transmitter | BS6T |
| Resistance transducer | BS6R |
| Intelligent signal conditioner | BS6M |
| AC current transducer | RPA |
| AC voltage transducer | RPV |
| AC current transducer | RPAT |
| AC voltage transducer | RPVT |
| AC current transducer | RPAX |
| AC voltage transducer | RPVX |
| Power transmitter | RPW |
| Power transmitter | RPK |
| Power transmitter | RPWK |
| Power factor transducer | RPPF |
| Frequency transmitter | RPF |
| Frequency transmitter | RPFT |
| AC current transducer | CPA |
| AC voltage transducer | CPV |
| AC current transducer | CPAT |
| AC voltage transducer | CPVT |
| AC current transducer | CPAX |
| AC voltage transducer | CPVX |
| Power transmitter | CPW |
| Power transmitter | CPK |
| Power transmitter | CPWK |
| Power factor transducer | CPPF |
| Frequency transmitter | CPF |
| Frequency transmitter | CPFT |
| Power transmitter | FPW |
| Power transmitter | FPK |
| Power transmitter | FPWT |
| Power transmitter | FPKT |
| Power transmitter | FPWK |
| DC transducer | FPD-1H |
| DC transducer | FPD-2H |
| DC transducer | FPDH-1H |
| DC transducer | FPDH-2H |
| AC current transducer | FPA |
| AC voltage transducer | FPV |
| AC current transducer | FPA2 |
| AC voltage transducer | FPV2 |
| AC current transducer | FPAR |
| AC voltage transducer | FPVR |
| AC current transducer | FPAT |
| AC voltage transducer | FPVT |
| AC current transducer | FPAX |
| AC voltage transducer | FPVX |
| AC current transducer | FPAX2 |
| AC voltage transducer | FPVX2 |
| AC current transducer | GPA |
| AC voltage transducer | GPV |
| AC current transducer | GPA2 |
| AC voltage transducer | GPV2 |
| AC current transducer | EPA |
| AC voltage transducer | EPV |
| AC current transducer | GPAT |
| AC voltage transducer | GPVT |
| AC current transducer | GPAX |
| AC voltage transducer | GPVX |
| AC current transducer | GPAX2 |
| AC voltage transducer | GPVX2 |
| AC current transducer | GPAS |
| AC voltage transducer | GPVS |
| Generator negative sequence current meter | FPFX-100 |
| Temperature transmitter | FT3 |
| Temperature transmitter | FT2 |
| Temperature transmitter | FT2-C |
| Temperature transmitter | GPT |
| Temperature transmitter | EPT |
| Shift transmitter | FPB |
Share This Story, Choose Your Platform!