• Overview
  • Details
  • More
Share Products Categories Channel Cart
1/5
Electronic Generator Over and Under Current Protective Relay图1Electronic Generator Over and Under Current Protective Relay图2Electronic Generator Over and Under Current Protective Relay图3Electronic Generator Over and Under Current Protective Relay图4

Electronic Generator Over and Under Current Protective Relay

Price $19.52
Min Order 50 Pieces  
Shipping from Zhejiang, China
Quantity
-+
Product details
HTHY-SSD
Electronic Motor Protective Relay
Current Relay
3
Ac
Enclosed Relay
Miniature
AC220V
0.5-6A
3-30A
10-60A
AKMAN
Carton Packing
77.2*63*51mm
Zhejiang China
85364900
Product Description
HTHY-SSD Digital Type Standard Over-current Relay with Ammeter




Specification
SettingOver-current051~5A
303~30A
6010~60A
Delay TimeD-Time1~30sec
Operating TimeO-Time0.5, 1~10sec
ResetManual(Instantaneous) Reset / Electrical Reset
Operation CharacteristicOver-currentDefinite Time Type
ToleranceCurrentI < 1A : ±0.05A , I > 1A : ±5%
TimeT ≤ 3s : ±0.2s , t > 3s : ±5%
Ambient
Temperature
Operation-20°C~60°C
Storage-30°C~80°C
Ambient Humidity30~85% RH without condensation
Control Voltage▪ 110 : 110VAC ±15%, 50/60Hz
▪ 220 : 220VAC±15%, 50/60Hz
▪ 24 : 24VAC/DC
Output Contacts2-SPST(1a1b)3A / 250VAC , Resistive
InsulationBetween Casing & Circuits500VDC Megger 10MΩ
Dielectric StrengthBetween Casing & Circuits2.0kV 60Hz , 1min
Between Contacts1.0kV 60Hz , 1min
Between Circuits2.0kV 60Hz , 1min
Mounting35mm Din Rail or Panel
Power ConsumptionLess than 2VA
Electrostatic DischargeIEC6100-4-2Level 3 : Air Discharge : ±8kV ,
Contact Discharge : ±6kV
Radiated Electromagnetic
Field Disturbance
IEC61000-4-3Level 3 : 10V/m ,80-1000MHz
 
EFT / BurstIEC61000-4-4Level 3 : ±2kV , 1min
SurgeIEC61000-4-5Level3 : 1.2X50μs, ±2kV (0° , 90° , 180° , 270°)
Conducted disturbanceIEC61000-4-6Level3 : 10V , 0.15 -80MHz
1MHz Burst disturbanceIEC61000-4-12Level3 : 2.5kV , 1MHz
EmissionIEC60255-25Radiated & Conducted Emission

How to setup:
1)Over-current : Set the rated motor current of its name plate. For protection of connected machinery with motor, it is recommended to set the 110~115% of real running current after motor current is stabilized.
2) Starting Delay Time : Set the expected run - up time of motor by D-Time knob.
3) Operating Time : Set trip delay time(O-Time knob) to desired trip time.