Electric Ball Valve Actuator 10nm Energy Saving for Floor Heating System

Price $0.00
Min Order 500 Pieces  
Shipping from Jiangsu, China
Quantity
-+
Product details
ZBA
ISO, CE
AC220V
Electric Power
Ordinary Temperature
Thread
Plastic
OEM
Cartons
Valves and actuators
China
Product Description

Product Description

10Nm Ball Valve Actuator with LCD Screen IP54 ZBA230DM works by Rs485 communication mode, and is suitable for proportional adjustment of water system valves in floor heating and central air condtioning. It can be used on two-way valves and three-way valves.

New Design Ball Valve Actuator 
Rotate LCD screen automatically
Energy saving
Power-off permanent memory function
Adjustable running time
Normally open/closed can be adjust after valve power on


Features
  • Lower noise, long life.
  • Easy operation, simple installation.
  • Manual adjustable, and power off control can be realized.
  • Precise valve opening position.
  • Brushless motor.
Technical Specifications
 
Model numberZBA230DM
FunctionRs485 communication mode
Power supply230V AC, 24V AC/DC
Power consumption5W for running, 1W for maintaining
Frequency50/60Hz
Stroke90°C/90s
Torque10Nm
Installation sizeM33X1.5
Protection levelIP54
Cable4x0.3 black PVC 0.5m
Sensor lengthø3.5x1m



Type of valves to be used

Installation typeModel numberThreadFlow coefficient KvsBody pressure MPaTurn off differential pressure MPaMedium temperature
Nut VB30F20A3/4"7.32.50.55-100°C
NutVB30F25A1"8.72.50.55-100°C
NutVB30F32A1 1/4"11.42.50.55-100°C
NutVB30F40A1 1/2"14.22.50.55-100°C
NutVB30F50A2"18.22.50.55-100°C

 

 

Installation Guide

 

Before carrying out maintenance work, the actuator must be disconnected from the power supply (unplug the power cord). At the same time, the water pump and isolation device in the particular part of the relevant pipeline should also be closed (if necessary), it should be cooled first to reduce the system pressure). When the lines are refilled, the system will ony work again if the valves and actuators are properly installed and connected.


 