• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/5
Drx-II-PS TPS Fast Thermal Conductivity Test Instrument图1Drx-II-PS TPS Fast Thermal Conductivity Test Instrument图2Drx-II-PS TPS Fast Thermal Conductivity Test Instrument图3Drx-II-PS TPS Fast Thermal Conductivity Test Instrument图4Drx-II-PS TPS Fast Thermal Conductivity Test Instrument图5

Drx-II-PS TPS Fast Thermal Conductivity Test Instrument

Price $0.00
Min Order 1 Set  
Shipping from Hunan, China
Quantity
-+
Product details
DRX-II-PS
1 Year
1 Year
220V
9031809090
Standard Exporting Wooden Case
220V
China
9031809090
Product Description
DRX-II-PS TPS Fast Thermal Conductivity Test Instrument
The equipment is mainly based on transient plane heat source technology in testing materials thermal conductivity, thermal resistance and thermal diffusivity by probe. It is widely used in electricity, automobile, material, biology pharmacy and other fields. Provide with multiple probe, software, devices and supporting, can used for testing thermal conduction performance of various types of materials.
Reference standard ISO 22007-2 2008. ASTM D5334, ASTM D5930.
Main features:
1. Direct measurement of transient thermal transmission, testing time in between seconds 5-160s can be set.
2. Won't influence by the thermal contact resistance like static method.
3. Don't need special sample preparation, only relatively flat sample surface.
4. It can be used on solid, powder, coating, film, liquid and anisotropic materials thermal physical parameter measurement.
5. The structure design of the sample table is clever, easy to operate, suitable for placing samples of different thickness, at the same time, simple and beautiful.
Main technical parameters:
Thermal conductivity 0.005-500 W/m.K
Temperature scopeRT ~ 200 °C/500°C/1000°C for choose, resolution: 0.1ºC
Material typeMetal, alloy, ceramics, ore, composite materials, silicon wafer, polymer, binder, paper, fabric, printed circuit board, propellant...
Test modulebasic, thin film, plate, anistropy, single face, specific heat
Probe sizeCylindrical Φ2- Φ30 mm
Specimen typeSolid, powder, film, coating material, etc.
Accuracy5 %
Reproducibility 3%
Sample thickness0.01~5mm
Data result analysisAutomatic thermal analysis software, Windows 10/7/XP  English
Supply voltageAC 220V±5%, power: 3.0kw
Main configurationsDRX-II-PS testing host, probe,  testing box, testing software, communication cable.