Product Description
| Calibration Medium | Pure Tap Water |
| Environmental Conditions | Atmospheric temperature is 3ºC-35ºC The relative humidity of the atmosphere is 15%-85% Atmospheric pressure is 86 KPa -106Kpa |
| Caliber Of The Meter Being Inspected | DN50, DN80, DN100, DN150, DN200, DN250, DN300 |
| Quantity For One Test | 1 each |
| Working Voltage | AC220V |
| Water Meter Sealing Test | Pressure Range (1.6~3.2) Mpa |
| Water Source Working Pressure | 0.2-1.0Mpa adjustable, air source working pressure: 0.4-0.7MPa |
| Meter Clamping Mechanism | Single Meter Independent Pneumatic Meter Clamping Device |
| Diameter | Φ32mm Telescopic stroke ≥80mm |
| Water Pump | South Water Pump CDMF-3-7, flow rate 10m3/h, head 62 meters |
| Water Tank | 200L |