• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
Conventional Fire Alarm Control Panel Alarm System图1Conventional Fire Alarm Control Panel Alarm System图2Conventional Fire Alarm Control Panel Alarm System图3Conventional Fire Alarm Control Panel Alarm System图4Conventional Fire Alarm Control Panel Alarm System图5Conventional Fire Alarm Control Panel Alarm System图6

Conventional Fire Alarm Control Panel Alarm System

Price $0.00
Min Order 10 Pieces  
Shipping from Zhejiang, China
Quantity
-+
Product details
CF-800X
Ce,RoHS,
1,2 or 4 Loops * 50 Point
Yes
House, Hotels, Market, etc
290X212X 88mm
2100g/Set
Metal
Sentek
1PC/Box, 5PCS/Carton
matel housing
China
8531100000
Product Description

Specification:


Conventional Fire Alarm Control Panel Alarm System
Main power: AC220V± 15%,50Hz/ AC110V± 15%,60Hz 
Battery: DC 24V (2 x 12V 3.3Ah)
Zone and sounder end of line resistors: 3.9KΩ,1W
Zone monitoring current:<4.5mA
Zone alarm current:>20mA
Zone short current:>110mA
Zone voltage: 24V±2V
Sounder alarm output: 3 x 300mA (max)/24VDC
Auxiliary Supply: 300mA/24V
Dimensions: 290 x 87.5 x 211.5mm
One set of fault relay contacts: Rated at 0.5A SELV
Humidity: ≤95%RH
Number of zones: 1,2,4
weight: 2100g (without battery)






Features:
• The CF800X panel is available on 1,2,4 zones.
• Each zone has a maximum capacity of 50 devices.
• It has 3 groups of sounders output circuits each capable of supplying 300mA.
• It has a 24V/300mA auxiliary supply.
• It has a set of fault relay contacts,rated at 0.5A SELV.
• It has the ability to disable any zone,any group of sounder.
• The panel will send a fault signal when there is zone short/open or sounder short/open.
• It has the ability to disconnect the zones and sounders automatically when there is zone short or sounder short.
   After the short is clear, the zones and sounders will recover.
• It has the sounder start/stop and delay facility (the delay time is 30-120 seconds in 30 seconds increments).
• It has the "rst "re alarm and subsequent "re alarm functions.
  The indicator of the "rst "re zone is #ashing and the subsequent"re zone is lit.
• It has the mains-lost silence function.After con"gure the mains lostsilence function,the panel will not send the main power lost fault signal.

 