Rail type dual phase meter
1.Product Introduction
Wireless gateway is a device that uses RS485 communication to connect PLC and PC terminals, with built-in ZigBee or LORA modules for forwarding data. Generally used in conjunction with LINK811S, LINK813S, ZSS and other products for data collection

2.Technical parameterWireless gateway is a device that uses RS485 communication to connect PLC and PC terminals, with built-in ZigBee or LORA modules for forwarding data. Generally used in conjunction with LINK811S, LINK813S, ZSS and other products for data collection


| Performance point | Performance index | |
| working power supply | Operating voltage range | AC 176~264V |
| Power consumption | <2.5W,5VA | |
| wireless communication interface | Interface form | ZIGBEE interface /LORA interface |
| Address range | 1~247 | |
| protocol | Modbus-RTU | |
| communication method | Mesh networking | |
| Communication distance | Point-to-point communication has an open sight distance of 1000m. | |
| Mounted quantity | Can mount 35 | |
| environmental conditions | Working temperature | -20ºC~70ºC |
| storage temperature | -40ºC~70ºC | |
| Working humidity | 0 ~ 95% does not condense. | |
| atmospheric pressure | 86kPa~106kPa | |
| mechanical character | vibrate | GB/T 11287 severity level 1 |
| lash | GB/T 14537 severity level 1 | |
| collide | GB/T 14537 severity level 1 | |
| Electromagnetic compatibility performance | Radio frequency electromagnetic field immunity test | GB/T 17626.3-2006 Severity Grade 3 |
| Electrical fast transient test | GB/T 17626.4-2008 Severity Grade 3 | |
| Attenuated oscillation wave immunity test | Severity grade 3-12-1998 | |
| Surge immunity | GB/T 17626.5-2008 Severity Grade 3 | |
| Radio frequency conduction immunity | GB/T 17626.6-2008 Severity Grade 3 | |
| radio disturbance | GB/T 17215.211-2006 7.5.8 Class B Equipment | |
| Interference degree of power frequency magnetic field | GB/T 17626.8-2006 Severity Grade 3 | |
| Electrical insulation performance | insulance | GBT 13729-2002, not less than 100MΩ. |
| dielectric strength | GB/T 13729-2002, power frequency voltage 2kV, 1 minute. | |
| surging | GB/T 13729-2002,1.2/50μs,5kV | |
3.Product perforation and installation diagram
4.About our service : * We could provide 7* 24-hour phone call after-sales service.
* We provide a 2-year guarantee time and will change the meter for you within 1 year if there's something wrong with the product. Except for natural disasters or man-made reasons.
* Recommend the most advanced application technology and management model in the industry to customers, and provide customers with detailed solutions.
5.Delivery Diagram