Cj Xmta-908t Temperature Controller with Time Function图1Cj Xmta-908t Temperature Controller with Time Function图2Cj Xmta-908t Temperature Controller with Time Function图3Cj Xmta-908t Temperature Controller with Time Function图4Cj Xmta-908t Temperature Controller with Time Function图5Cj Xmta-908t Temperature Controller with Time Function图6

Cj Xmta-908t Temperature Controller with Time Function

Price $25.80
Min Order 1 Piece  
Shipping from Zhejiang, China
Quantity
-+
Product details
XMTA-908T
Customized
CE
Cj
LED
96*96
Digital
Temperature Controller
Electronic Type
CJ
1PCS/Box
ISO 9001: 2008 Others
China
9032900090
Product Description

Product Description
Specifications

Temperature controller
PID
intelligence dual row 4-LED displays
displaying the measured value and set value.


Main technical specification

1. Measurement deviation: ≤ ± 0.5%F. S± 1B

2. Cold end compensating deviation: ≤ ± 2.0C

3. Sampling cycle: 0.5S

4. Control cycle: Relay output  2-120S, other is 2S.

5. Relay output contact capacity: AC220V/5A (resistance load) or AC220V/0.3A

(perceptual
Load)

6. Driving controllable pulse output: ≥ 3V scope, ≥ 40us width's over zero or trigger contact
pulse

7. Driving solid relay signal output: Driving electric current≥ 15mA, voltage≥ 9V.

8. Continuous PID: 0-10mA (load 500± 200Ω ), 4-20mA (load 250± 100Ω ), or 0-5V

(load≥ 100kΩ ), 1-5V (load≥ 100kΩ )

9. Exterior and hole size(mm): 96× 96× 110 92× 92

10. Power: AC85V242V, 50/60Hz

11. Working condition: Temperature 0-50.0C, relative humidity≤ 85%RH, without corrode

and strong electric radiation.

Panel instruction(consult)
Connection scheme(consult)

Model code


                                     XMT (    ) - 9 (   )  8  (   )
                                                1        2    3     4       5

1:The surface dimension (mm)
Blank: 160×80×85 Installation hole 156×76 A: 96×96×80 Installation hole 92×92
D: 72×72×80 Installation hole 68×68 E: 48×96×75 Installation hole 44×92
F: 96×48×75 Installation hole 92×44 G: 48×48×110 Installation hole 44×44
S: 80×160×85 Installation hole 76×156

2: Operation display method:'9' 4-key gentle push-switch setting,double row 4-LED digital display,PID and ON/OFF(P=0)control can select.

3:Additional alarm:'1' No over-temperature alarm, but a group of time control output;
'3' A group of alarm ( upper limit alarm or follow-up alarm ) and a group of time-control relay output;
'5' No over-temperature alarm, but a group of time control output for buzzer alarm .

4:Input: '8' input signal can interchange free(no voltage and current input)

5:Suffix Blank:relay output G:solid relay output T:Time control function

Inner parameter

Series
CodeNameSetting rangeManualEx-Factory
0SPSetting value of temperatureDetermined by P-SL P-SHOutput corresponds to "OUT" indicator light50.0
1AL1Alarm 1Determined by P-SL,P-SH when the upper and lower limit alarm, it is0~50.0 when the positive deviation alarm and negative deviation alarm
please refer to ALP1
Corresponds to "ALM1" indicator light
300
2AL2Alarm 2please refer to ALP2
Corresponds to "ALM2" indicator light
100
3PProportion modulus0~100When the P↑, the proportion and differential
function↓; If the P↓, the proportion and
differential function↑
When P=0, the meter is ON/OFF control
15
4ICalculus time0~2000S
 
240
5dDifferential time0~200S
 
30
6AtSetting itselfON/OFFON: open setting itself function
OFF: close setting itself function
OFF
7tControl period1~120SThe movements cycle ON/OFF of Setting relays control is no meaning,
Relay is 20S,  other is 2S.
20
8HyMain control by
drop in level
0.1~50.0Only have meaning when main control output is ON/OFF(P=0)1.0
9Hy-1drop in level
of  AL1
0.1~50.0It is used as setting of drop in level
for AL1 relay output
1.0
10Hy-2drop in level
of  AL2
0.1~50.0It is used as setting of drop in level
for AL2 relay output
1.0
11PbSensor error amendment±20.0The sensor have deviation can use item to revisal0
12FILTFilt modulus0~50Is the software filter constants of  measurement sampling. The constant ↑, the measurements antijamming capability↑, but the measurement and system time ↓.20
13dpDisplay precision0~11: have radix point; 0: have not radix point0
14P-SHThe max.value of temperature range-They are used to reset proper temperature range as per user'application.
As for the Max. temperature range for
different inputs, please refer to Sn,
P-SH≥P-SL
1300
15P-SLThe min.value of temperature range-0
16OUTLThe min. value
of allowable output
0~OUTHCan achieve low and high output limiter. Meaningless when manual and ON/OFF control0
17OUTHThe max. value
of allowable output
OUTL~200200
18ALP1Alarm1  and output definition0~4'o':indicate no alarm;  '1':upper limit alarm
'2':lower limit alarm;
'3': Upper-limit (deviation) Alarm;
'4': Lower-limit (deviation) Alarm;
-
19ALP2Alarm2  and output definition0~4-
20COOLSystem function choice0~1'0': reverse control(heat)
'1': positive control(cool)
0
21OPPOOpen power output0~100Soft start functionthat meters coefficient after first export of electric power0
22LOCKCode lock0~50LOCK=0, all the parameter can be revised
LOCK=1, only the SP can be revised
LOCK>1, all the parameter can not be revised
0
23SnInput typeCU50( )
PT100( )
PT100( )
K( ),E( ),J( )
T( ),S( )
CU50 (-50.0~150.0ºC) ;
PT1 (-200.0~200.0ºC) ;
PT2 (-200.0~600.0ºC) ;K (0~1300ºC) ;
E (0~700.0ºC) ;     J (0~900.0ºC) ;
T (-200~400.0ºC) ;  S (0~1600ºC) ;

 
24OP-AOutput type
RLP( )
SSR( )
Zero( )
Mut( )
0~10MA( )
4~20MA( )
RLP Relay output mode
SSR Solid state relay
Zero  SCR zero voltage switching
Mut  SCR phase-shift trigger
0~10MA linearity  control electric current output
4~20MA  linearity  control electric current output

__