Chint Nl1-63 3000A 22.5ka2s 2p 25A 40A 63A 30mA 100mA 300mA Type a or Type AC Belgium RCD Residual Current Circuit Breaker图1Chint Nl1-63 3000A 22.5ka2s 2p 25A 40A 63A 30mA 100mA 300mA Type a or Type AC Belgium RCD Residual Current Circuit Breaker图2Chint Nl1-63 3000A 22.5ka2s 2p 25A 40A 63A 30mA 100mA 300mA Type a or Type AC Belgium RCD Residual Current Circuit Breaker图3Chint Nl1-63 3000A 22.5ka2s 2p 25A 40A 63A 30mA 100mA 300mA Type a or Type AC Belgium RCD Residual Current Circuit Breaker图4Chint Nl1-63 3000A 22.5ka2s 2p 25A 40A 63A 30mA 100mA 300mA Type a or Type AC Belgium RCD Residual Current Circuit Breaker图5Chint Nl1-63 3000A 22.5ka2s 2p 25A 40A 63A 30mA 100mA 300mA Type a or Type AC Belgium RCD Residual Current Circuit Breaker图6

Chint Nl1-63 3000A 22.5ka2s 2p 25A 40A 63A 30mA 100mA 300mA Type a or Type AC Belgium RCD Residual Current Circuit Breaker

Price $10.00
Min Order 30 Pieces  
Shipping from Shanghai, China
Quantity
-+
Product details
NL1-63
Low Voltage Circuit Breakers
Air
Fixed
ELCB
2
Overcurrent Protection
ISO9001-2000, CE, CB, CCC
Chint
Nl1-63
Type a or Type AC
25A, 40A, 63A
Chint
Cartons
China
853620
Product Description
Chint NL1-63 3000A 22.5kA2s 2P 25A 40A 63A 30mA 100mA 300mA Type A or Type AC Belgium RCD Residual Current Circuit Breaker
 

Function

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.

 

Selection

 

1. Detectable wave form

- AC class

Tripping is ensured for slowly increasing sinusoidal AC residual currents.

- A class Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

- S, G/SI class

Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

 

2. Tripping sensitivity

10mA - precision instrument leakage protection and bathroom use.

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula IΔn <50/R, to provide protection against indirect contacts; 300mA/500mA - protection against indirect contacts, as well as fire hazard.

 

3. Tripping time

Instantaneous - It ensures instantaneous tripping (without time-delay).

Short time delay - It ensures any tripping at least 10ms.

Selective - It ensures total discrimination with a nonselective RCD placed downstream.


Technical data:

Overall and mounting dimensions (mm):


Buyer review
Loading review details...
Contact

Shanghai Newtrend Electric Co., Ltd.

Audited Supplier4 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

You May Like
Home > Products > Electrical & Electronics > Breaker & Protector > Circuit Breaker