SHDN-20-DD-35M(A)
Insulated
Solid
Heating
Alloy Wire
PVC
XLPE
Round Wire
LSOH
CE, CCC, RoHS, VDE
Senphus
17W/M, 18W/M, 19W/M, 20W/M, You Choose
White, Red, Yellow, etc. If You Need Other Color,
5m ,10m,20m,50m,130m,220m, You Choose
2m, 3m ,4m, etc.
Blue, Orange, Red, Purple, Rose, etc .
110V,120V,220V,230V,240V
Senphus
Spool, Carton
Jiangsu, China (Mainland)
Product Description
CE UL approval Underfloor Heating System (SHDN-20-DD) :
Senphus resistance heating cable manufactured according to directives of the International Electrotechnical
Commission: IEC STANDARD Publication 800 - heating cables for a nominal current of 300/500V used in the heating of rooms as well as freezing prevention;
Certified by the BBJ SEP (Quality Test Office of the Association of Electrical Engineers) and certified for use in construction industry;
Manufactured according to the ISO 9002 Quality Assurance System.
Applications of resistance heating cable
floor heating cable for houses and apartments, summer cottages, garages,
storages, stores, churches - as the basic heating system;
floor heating cable for selected compartments such, as additional heating for
stone floors in bathrooms, kitchens, living rooms, workshops...
floor heating cable for greenhouses, pigsties, farms, cold storages;
Anti-freezing protection for gutters, down pipes, pipelines, water tanks;
Protection against icing for ramps, walkways, stairways, porches, terraces.
Advantages of CE UL approval Underfloor Heating System (SHDN-20-DD):
COMFORT,NEAT DESIGN,HEALTH,SAFETY,EXPENSES
All you should do is to regulate or preset the temperature you require;
Uniform temperature in all rooms and compartments;
Low temperature of the heating surface;
Your floor is warm in a short time;
The heating equipment is invisible;
No more dirty compartments (boiler room, etc.);
Perfect thermal comfort: walls and ceiling are uniformly warm, temperature is uniform across each compartment;
The cable is screened on its entire length;
The screen is effectively grounded;
The differential switch eliminates electric shock hazard;
Expenditures for the system installation are exceptionally low compared to traditional systems;
Low energy costs due to the precise temperature regulation.
Thermostat Specifications for your choice
Floor resistance heating cable types
Senphus resistance heating cable manufactured according to directives of the International Electrotechnical
Commission: IEC STANDARD Publication 800 - heating cables for a nominal current of 300/500V used in the heating of rooms as well as freezing prevention;
Certified by the BBJ SEP (Quality Test Office of the Association of Electrical Engineers) and certified for use in construction industry;
Manufactured according to the ISO 9002 Quality Assurance System.
Applications of resistance heating cable
floor heating cable for houses and apartments, summer cottages, garages,
storages, stores, churches - as the basic heating system;
floor heating cable for selected compartments such, as additional heating for
stone floors in bathrooms, kitchens, living rooms, workshops...
floor heating cable for greenhouses, pigsties, farms, cold storages;
Anti-freezing protection for gutters, down pipes, pipelines, water tanks;
Protection against icing for ramps, walkways, stairways, porches, terraces.
Advantages of CE UL approval Underfloor Heating System (SHDN-20-DD):
COMFORT,NEAT DESIGN,HEALTH,SAFETY,EXPENSES
All you should do is to regulate or preset the temperature you require;
Uniform temperature in all rooms and compartments;
Low temperature of the heating surface;
Your floor is warm in a short time;
The heating equipment is invisible;
No more dirty compartments (boiler room, etc.);
Perfect thermal comfort: walls and ceiling are uniformly warm, temperature is uniform across each compartment;
The cable is screened on its entire length;
The screen is effectively grounded;
The differential switch eliminates electric shock hazard;
Expenditures for the system installation are exceptionally low compared to traditional systems;
Low energy costs due to the precise temperature regulation.
Thermostat Specifications for your choice
R8600 | |
Functions | On/Off control, digital display, 7-day programmable |
Power source | 100-240VAC 50/60HZ |
Relay contact | 250VAC 16A |
Room temperature setting range | 5°C(41°F)~35°C(95°F) |
Floor temperature setting range | 5°C(41°F)~45°C(113°F) |
Accuracy | ±1°C or ±33.8°F |
Dimensions | 94mm X 87mm X44mm |
Color | White |
Floor temperature sensor | 2-wire, 3.0m lead wire |
R6900 | |
Functions | On/Off control, digital display, 7-day programmable |
Power source | 198-242VAC 50/60HZ |
Relay contact | 250VAC 25A |
Ambient temperature-operation | 0°C-50°C |
Ambient temperature-transport | -10°C-60°C |
Room temperature setting range | 5°C~35°C |
Floor temperature setting range | 5°C~60°C60°C(factory default 40°C) |
Accuracy | ±1°C |
Dimensions | 86mm X 86mm X13mm |
Color | White |
Floor temperature sensor | 2-wire, 3.0m lead wire |
Floor resistance heating cable types
Volt | Specification | Power (W) | Resistance @20oC+10/-5% | Length (M) |
230V | SHDN-20-DD-5M(A) | 100 | 529.00 | 5 |
230V | SHDN-20-DD-7.5M(A) | 150 | 352.67 | 7.5 |
230V | SHDN-20-DD-10M(A) | 200 | 264.50 | 10 |
230V | SHDN-20-DD-15M(A) | 300 | 176.33 | 15 |
230V | SHDN-20-DD-20M(A) | 400 | 132.25 | 20 |
230V | SHDN-20-DD-25M(A) | 500 | 105.80 | 25 |
230V | SHDN-20-DD-30M(A) | 600 | 88.17 | 30 |
230V | SHDN-20-DD-35M(A) | 700 | 75.57 | 35 |
230V | SHDN-20-DD-42.5M(A) | 850 | 62.24 | 42.5 |
230V | SHDN-20-DD-50M(A) | 1000 | 52.90 | 50 |
230V | SHDN-20-DD-60M(A) | 1200 | 44.08 | 60 |
230V | SHDN-20-DD-70M(A) | 1400 | 37.79 | 70 |
230V | SHDN-20-DD-80M(A) | 1600 | 33.06 | 80 |
230V | SHDN-20-DD-90M(A) | 1800 | 29.39 | 90 |
230V | SHDN-20-DD-100M(A) | 2000 | 26.45 | 100 |
230V | SHDN-20-DD-110M(A) | 2200 | 24.05 | 110 |
230V | SHDN-20-DD-120M(A) | 2400 | 22.04 | 120 |
230V | SHDN-20-DD-130M(A) | 2600 | 20.35 | 130 |