Amc16L-Dett Energy Meters 6-Way Hall Access Power Distribution Units图1Amc16L-Dett Energy Meters 6-Way Hall Access Power Distribution Units图2Amc16L-Dett Energy Meters 6-Way Hall Access Power Distribution Units图3Amc16L-Dett Energy Meters 6-Way Hall Access Power Distribution Units图4Amc16L-Dett Energy Meters 6-Way Hall Access Power Distribution Units图5Amc16L-Dett Energy Meters 6-Way Hall Access Power Distribution Units图6

Amc16L-Dett Energy Meters 6-Way Hall Access Power Distribution Units

Price $70.00
Min Order 1 Piece  
Shipping from Shanghai, China
Quantity
-+
Product details
AMC16L-DETT
2 Years
2 Years
Digital
Indirect Connected
Multi-Functional Energy Meter
Three-phase Four-wire
Electronic Meter
Terminal
Continuous Wave
Energy Meter
RoHS, ISO, CE
Customized
Acrel
Carton
89.7*87.8*52mm
China
9028301400
Product Description

Accuracy

1%In ≤ I ≤10%In error±2.5%;

I>10%In error±2%

 

Voltage range

-40V~-60VDC

 

Power consumption

≤2W( no hall power supply output)

 

Power supply output

+12V/100mA, -12V/50mA

 

Power consumption

≤2W( no hall power supply output)

Dimension(L*W*H)

89.7*87.8*52mm

 

Installation

DIN 35 mm

 

Clock

≤0.5S/d(23ºC), ≤1S/d(-20ºC-60ºC)

 

Current

1.2 times continued

Input

DC rated voltage

1 channel:-48VDC

DC current

6 channels hall sensors : total 200A/5V, China Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd channel reserve 100A/5V.

Commercial power monitoring

1 channel :0-5 VDC

Overload capacity

Voltage:1.2 times continued, 2 times continued 1 s.

Current: 1.2 times continued, 10 times continued 1 s. 

Accuracy(superposition hall sensors)

1%In≤I≤10%In, error ±2.5%; I>10%In; error ±2%

Measurement resolution

Voltage: 0.01 V, Current: 0.01 A, Power: 0.01 kw, Energy: 0.01 kwh

Functions

Basic function

Monitor device system time, total voltage, total current, power, energy, each channel voltage, current, power , energy;LCD display, RS485 communication;

Metering function

Start current: under rated voltage, when the load current value of the meter doesn't exceed 1% of the max.current, the meter starts.

Shunt running current: When there is no current in the current circuit of the meter, and 85%~125% of the rated voltage is applied on the voltage circuit, the calculator shall not have more than one digital change.

Alarm function

DC under-voltage, DC over-voltage, one power down, module voltage loss, metering branch error, internal program error, clock error, memory failure, AC input power failure.