125A
1 Year
Dual Power ATS
Automatic Transfer Switch Generator ATS
160A
125A
a-Class
DMC \ Copper \ Silver
Stable and Reliable Quality
4 Pole
VISION
Carton Packing for ATS
China
Product Description

VISION ATS 20A 63A 80A 100A 125A 160A 250A 400A 630A 800A
1000A 1250A 1600A 2000A 2500A 3200A
VSQ Automatic Transfer Switch (ATS) is used under conditions of AC660V 50/60Hz or DC250V. It is two-stage PC class type with electromagnetism drive structure, which can make fast load transfer (transfer time ≤80ms) of two power circuits. It can be widely used for national one-class load, for example: high buildings, post, telecommunications, coal mines, ships, industrial assembly lines, health care,facilities etc. The two power circuits can be grid, auto start genset, storage battery etc.
When the mains power fails or is in an abnormal state such as phase loss, overvoltage, or undervoltage, the ATS system
automatically starts the standby diesel generator set according to the preset mains loss confirmation delay. After confirming that the output voltage of the generator set is normal, it automatically switches to For the generator set, the load is powered by the generator set; when the mains power returns to normal, it will automatically switch to restore the mains power supply to the load after confirmation by a preset delay. After the generator set is unloaded, it will automatically stop after a preset cooling operation.
When the mains power fails or is in an abnormal state such as phase loss, overvoltage, or undervoltage, the ATS system
automatically starts the standby diesel generator set according to the preset mains loss confirmation delay. After confirming that the output voltage of the generator set is normal, it automatically switches to For the generator set, the load is powered by the generator set; when the mains power returns to normal, it will automatically switch to restore the mains power supply to the load after confirmation by a preset delay. After the generator set is unloaded, it will automatically stop after a preset cooling operation.

* Good installation performance
* The adoption of zero-crossing detect technique, emergency can be forced to set zero (simultaneously cut off two power supply)
* with obvious on-off indication, padlock and other functions, to achieve the isolation between the power supply and load
* High reliability, over 6000 times service life
* High degree of automation
* The adoption of zero-crossing detect technique, emergency can be forced to set zero (simultaneously cut off two power supply)
* with obvious on-off indication, padlock and other functions, to achieve the isolation between the power supply and load
* High reliability, over 6000 times service life
* High degree of automation
* Good electromagnetic compatibility, strong anti-interference ability, no external interference * The switch has multiple input / output interfaces, which is convenient for remote PLC control and system automation.



Main Technology Parameters


Recommended Cabinet Installation Dimension | ||||
Model | Recommended Cabinet Dimension (L*W*H cm) | Recommended Cabinet Dimension (L*W*H cm) | ||
VSQ3-100A-VSQ3-250A | 50*40*80 | 50*25*60 | ||
VSQ3-300A-VSQ3-630A | 60*50*180 | 55*45*160 | ||
VSQ3-800A -VSQ31250A | 80*60*220 | 75*60*180 | ||
VSQ3-1600A | 80*60*220 | 75*60*200 | ||
VSQ3-2500A-VSQ3-3200A | 80*80*220 | 75*80*200 | ||
Reference only ,please according to the actual conditions. |
Product name | Net weight(KG) | DIMENSION/SET (cm) | DIMENSION/CTN(CM) |
VSQ3-100A | 4 | 28*12*17 | 38.5*30*37 |
VSQ3-160A | 7 | 34.5*21.5*23 | 45.5*37.5*25.5 |
VSQ3-250A | 9.5 | 42*21.5*26 | 46.5*45*29 |
VSQ3-400A | 17.5 | 53*30*33.5 | 53*30*33.5 |
VSQ3-630A | 18.5 | 53*30*33.5 | 53*30*33.5 |
VSQ3-1000A | 47.5 | 72*40*39 | 72*40*39 |
VSQ3-1250A | 50 | 72*40*39 | 72*40*39 |
VSQ3-1600A | 52.5 | 72*40*39 | 72*40*39 |