75A 3phases 4wires Power Factor Correction Device Active Harmonic Filter Wall Mounted Ahf Manufacturer图175A 3phases 4wires Power Factor Correction Device Active Harmonic Filter Wall Mounted Ahf Manufacturer图275A 3phases 4wires Power Factor Correction Device Active Harmonic Filter Wall Mounted Ahf Manufacturer图375A 3phases 4wires Power Factor Correction Device Active Harmonic Filter Wall Mounted Ahf Manufacturer图475A 3phases 4wires Power Factor Correction Device Active Harmonic Filter Wall Mounted Ahf Manufacturer图575A 3phases 4wires Power Factor Correction Device Active Harmonic Filter Wall Mounted Ahf Manufacturer图6

75A 3phases 4wires Power Factor Correction Device Active Harmonic Filter Wall Mounted Ahf Manufacturer

Price $1800.00
Min Order 1 Piece  
Shipping from Shanghai, China
Quantity
-+
Product details
HKK-APF-75/400-4B
Distribution Metering Box
ISO9001:2000, CCC, CE
All- packaged Type
Low Voltage
486*88*504 mm
Power Factor Correction
Aluminum-Zinc Coated Case
IP30
Huakun
Wall Mounted/Rack Mounted
3p3w/3p4w
<65dB
2~50th Harmonic Order
> 97%
Harmonic Correciton ,Reactive Var Compensation
Huakun
Wooden Box
682*567*277cm
Shanghai, China
8543709990
Product Description

Active harmonic filters (AHFs/APF) are typically stand-alone devices that reduce the high levels of harmonics produced by energy efficient non-linear loads.They work by injecting harmonics into the electrical system in equal and opposite measure to the existing system harmonics.As previously mentioned, harmonic filters are used to eliminate harmonic distortion caused by excess currents in and out of appliances. It can prevent large quantities of harmonics from causing damage to equipment, downtime of operation, and preventing an increase in operating costs.
The Active power filter monitors the load current real-time through the external current transformer CT, and extracts the harmonic component of the load current through the internal DSP computing, then sends it through the PWM signal to the internal IGBT, the inverter produces a current equal to the load harmonic and opposite to the harmonic direction and injects the current into the grid to compensate the harmonic current realizing the function of harmonic control.
System parameters
Rated input wire voltage
3 8 0 V(-1 5%~+2 0%)
Grid frequency
5 0 / 6 0 H z ( r a n g e : 4 5 H z~6 2 H z)
Number of parallel machines
1 ~ 1 0 s e t s
Overall efficiency
≥9 7%
Grid structure
T h r e e - p h a s e t h r e e - w i r e / t h r e e - p h a s e f o u r - w i r e
Current transformer
1 5 0/5~1 0 0 0 0/5
Circuit topology
T r i - l e v e l
 P e r f o r m a n c e   i n d e x
Response time
<1 5 m s
Scope of compensation
F r o m - 1 t o 1 , c a p a c i t i v e a n d i n d u c t i v e c o n t i n u i t y i s a d j u s t a b l e
Cooling mode
I n t e l l i g e n t a i r c o o l i n g
Noise index
<5 6 d B
Buyer review
Loading review details...
Contact

Shanghai Huakun Electrical Company Ltd.

Audited Supplier3 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

You May Like
Home > Products > Electrical & Electronics > Power Supply & Distribution > Power Distribution Cabinet & Box